Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Packing inserts

Packed inserts Packing the vaporizing chamber, e.g. with (si-... [Pg.307]

Roche Applied Science (2006) Anti-digoxigenin-POD, Fab fragments, package insert. Roche Diagnostics Corporation, Roche Applied Science, Indianapolis, IN. http //www. roche-applied-science.com/pack-insert/ 1333062a.pdf... [Pg.255]

The action of mechanically erecting, inserting primary pack, insertion of leaflet, then the closing of the carton is another world in which technical expertise may be required. The criteria on which the form of carton filling will be decided include, quantity per batch/lot/order, size and weight of the goods to be cartoned, cartonboard caliper, design of closure flaps, and what else, apart from the primary container, has to be inserted. [Pg.124]

An online LC detector is necessary during method development with spiked samples. The GC is equipped with an injector suitable for large volume injections (LVI). A regular programmed temperature vaporizer (PTV) with a packed insert liner and a solvent vapor vent valve, or an on-column injector with retention gap and solvent vapour exit can be used. Conventional liquid extraction techniques can be replaced with this setup completely and run fully automated for a large sample series. [Pg.26]

The transition metal structures consist of close-packed (p. 26) arrays of relatively large atoms. Between these atoms, in the holes , small atoms, notably those of hydrogen, nitrogen and carbon, can be inserted, without very much distortion of the original metal structure. to give interstitial compounds (for example the hydrides, p. 113). [Pg.368]

The temporary filling of the combustion tube D is now inserted this is in part replaced after every combustion. Sufficient wire-form copper oxide is added so that it just emerges to the left of the furnace E when the tube (not including the beak) is protruding 10-15 mm. at the beak end this constitutes the main oxidative packing of the tube. This is followed by 25 mm. of M.A.R. powder-form" copper oxide, followed by the sample suspended in more copper oxide, and backed by an oxidised copper spiral, 50 mm. in length. [Pg.486]

Fig. 1. A, hoUow-fiber spool B, hoUow-fiber cartridge employed ia hemodialysis C, cartridge identical to item B demonstrating high packing density D, hoUow-fiber assembly employed for tissue ceU growth E, hoUow-fiber bundle potted at its ends to be inserted into a cartridge or employed ia a situation... Fig. 1. A, hoUow-fiber spool B, hoUow-fiber cartridge employed ia hemodialysis C, cartridge identical to item B demonstrating high packing density D, hoUow-fiber assembly employed for tissue ceU growth E, hoUow-fiber bundle potted at its ends to be inserted into a cartridge or employed ia a situation...
Spinning pack Chimney air chamber Filaments Chimney door Convergence guide Insert tube Threading air valve... [Pg.252]

One-Step Cameras and Processors. The eadiest one-step cameras used roU film and completed processing inside a dark chamber within the camera (9). The first instant color film, Polacolor, was provided in roU film format to fit these cameras. Flat-pack film cameras (Fig. 2), introduced in 1963, permitted the film to be drawn between processing rollers and out of the camera before processing was completed (10). Film holders for instant 10 X 13 cm (4x5 in.) film packets contain retractable rollers that permit the film to be loaded without mpturing the pod (11). For 20 x 25 cm (8 x 10 in.) films, the processing rollers are part of a tabletop processor. The exposed film, contained in a protective black envelope, and a positive sheet with pod attached are inserted into separate slots of a tray that leads into the processor. The film passes through the rollers into a covered compartment within which processing is completed. [Pg.486]

The secondary and tertiary structures of myoglobin and ribonuclease A illustrate the importance of packing in tertiary structures. Secondary structures pack closely to one another and also intercalate with (insert between) extended polypeptide chains. If the sum of the van der Waals volumes of a protein s constituent amino acids is divided by the volume occupied by the protein, packing densities of 0.72 to 0.77 are typically obtained. This means that, even with close packing, approximately 25% of the total volume of a protein is not occupied by protein atoms. Nearly all of this space is in the form of very small cavities. Cavities the size of water molecules or larger do occasionally occur, but they make up only a small fraction of the total protein volume. It is likely that such cavities provide flexibility for proteins and facilitate conformation changes and a wide range of protein dynamics (discussed later). [Pg.181]


See other pages where Packing inserts is mentioned: [Pg.294]    [Pg.337]    [Pg.667]    [Pg.47]    [Pg.431]    [Pg.326]    [Pg.36]    [Pg.370]    [Pg.294]    [Pg.184]    [Pg.107]    [Pg.4]    [Pg.94]    [Pg.294]    [Pg.337]    [Pg.667]    [Pg.47]    [Pg.431]    [Pg.326]    [Pg.36]    [Pg.370]    [Pg.294]    [Pg.184]    [Pg.107]    [Pg.4]    [Pg.94]    [Pg.3]    [Pg.471]    [Pg.471]    [Pg.472]    [Pg.473]    [Pg.118]    [Pg.339]    [Pg.533]    [Pg.196]    [Pg.475]    [Pg.300]    [Pg.585]    [Pg.767]    [Pg.771]    [Pg.1070]    [Pg.468]    [Pg.112]    [Pg.92]    [Pg.227]    [Pg.284]    [Pg.41]    [Pg.307]    [Pg.229]    [Pg.31]    [Pg.365]    [Pg.121]   
See also in sourсe #XX -- [ Pg.366 ]