Overpressure static

Bv this method, in general, the expecl ed inherent maximum explosion overpressure of the order P = 7 to 10 bar will be reduced to a value of Pred.max < 2 bai. In this case, the static activation overpressure of the venting device is < 0.1 bar. The resulting P,ed,max i i y not exceed the design pressure of the equipment. The explosion as such is not prevented only the dangerous consequences are limited. However, subsequent fires must be expecl ed. [Pg.2326]

Rupture disks or explosion doors may be used as venting devices. Safety valves are not suitable for this purpose. Obviously, the static-activation overpressures Ps at of he venting devices have to be equal to or smaller than the strength of the equipment to be protected (c-orre-sponding to the Pred.max)-... [Pg.2326]

Length-to-diameter ratio of vessel Static activation overpressure Ps,ai of venting device... [Pg.2327]

In the methane and hydrogen jet experiments, blast static overpressure was measured at various distances from the cloud (Figure 4.6). The propane jet experi-... [Pg.77]

Relief Valve a relief valve is an automatic spring loaded pressure-relietdng device actuated by the static pressure upstream of the valve, and which opens further with increase in pressure over the opening pressure. It is used primarily for liquid ser dce [1,10] (Figure 7-lA and 7-IB). Rated capacity is usually attained at 25 percent overpressure. [Pg.400]

Safety Valve this is an automatic pressure-relieving detice actuated by the static pressure upstream of the valve and characterized by rapid full opening or pop action upon opening [1,10], but does not reseat. It is used for steam or air service (Figure 7-2). Rated capacity is reached at 3%, 10% or 20% overpressure, depending upon applicable code. [Pg.400]

Safety-Relief Valve this is an automatic pressure-relieving device actuated by the static pressure upstream of the valve and characterized by an adjustment to allow reclosure, either a pop or a non-pop action, and a nozzle type entrance and it reseats as pressure drops. It is used on steam, gas, vapor and liquid (with adjustments), and is probably the most general tyqDe of valve in petrochemical and chemical plants (Figures 7-3, 7-3A, and 7-4). Rated capacity is reached at 3% or 10% overpressure, depending upon code and/or process conditions. It is suitable for use either as a safety or a relief valve [1,10]. It opens in proportion to increase in internal pressure. [Pg.400]

Figures 2 through 9 are design charts for ultraviolet stabilized polycarbonate under blast load. Charts are provided for pane thicknesses of 1/4, 3/8, 1/2, and 1 inch for pane areas up to 25 ft at pane aspect ratios (pane length to width ratios) of 1.00, 1.50, 2.00 and 4.00. The charts relate the peak experienced blast overpressure capacity, B, for convenient pane dimensions across the spectrum of encountered blast durations. Depending on the orientation of the window to the charge, the blast overpressure may either be incident or reflected. The pane dimensions (measured across the span from the gasket centerline) peak blast capacity at 1000 msec, B, static frame design pressure, r, and the required bite are printed to the right... Figures 2 through 9 are design charts for ultraviolet stabilized polycarbonate under blast load. Charts are provided for pane thicknesses of 1/4, 3/8, 1/2, and 1 inch for pane areas up to 25 ft at pane aspect ratios (pane length to width ratios) of 1.00, 1.50, 2.00 and 4.00. The charts relate the peak experienced blast overpressure capacity, B, for convenient pane dimensions across the spectrum of encountered blast durations. Depending on the orientation of the window to the charge, the blast overpressure may either be incident or reflected. The pane dimensions (measured across the span from the gasket centerline) peak blast capacity at 1000 msec, B, static frame design pressure, r, and the required bite are printed to the right...
Static activation overpressure P Pressure at which the retaining element breaks or releases such that the venting element is able to open when the rate of pressure rise is < 0.1 bar/min. [Pg.15]

Static activation overpressure of venting device Pstat < 0.1 bar... [Pg.18]

Static activation overpressure of rupture disk 0.1 bar < Pstat < 0.5 bar... [Pg.18]

Most blast door manufacturers opt to perform static load tests on prototype assemblies of low-range blast doors to demonstrate that the assembly will resist the blast overpressure specified. Static tests should be accepted only if the dynamic structural response and dynamic load factors have been considered and the door, frame, and restraining hardware are manufactured using the same materials, dimensions, and tolerances as those in the prototype static test. [Pg.200]

The explosion had all the characteristics of a detonation. A plot of overpressure destruction vs. distance statics fits exactly on known TNT detonation curves. Based on the stoichiometric combustion, my calculations indicate that the explosion had the force of 10 to 12 tons of TNT. [Pg.88]

Rated overpressure of compressed air grid Minimum overpressure of compressed air grid Rated overpressure of logic elements Minimum pressure differential Rated pressure differential Maximum pressure differential Pressure differential during purging Static test pressure differential Purging volume... [Pg.147]

Regarding the overpressure test, an overpressure of 1.5 times the reference pressure is required by the d-standards, with a minimum of 3.5 bar (referring to atmospheric pressure). This test may be a static test using a liquid (oil, water) or compressed air (in this case, to avoid parts of an enclosure which fails becoming dangerous projectiles, the overpressure test shall be made with a barrier - e.g. within a closed testing vessel) or a dynamic test based upon the same procedure as described for the determination of the reference... [Pg.436]

Instrumentation layout for the tests is shown schematically in Figure 12. Instrumentation for the Group 5 Suppressive Shield tests is tabulated in Table III. Burning time was measured using photocells in the shield wall. Thermocouples in the bulk pyrotechnic were used to obtain an indication when the material was completely burned. Static overpressure was measured on large charges to estimate confinement effects. Radiant heat flux outside the shield was measured with Keithley 86o flux meters. [Pg.46]

On blast environment, a predictive capability for characteristics of free air blast is available in the literature (2, 7) Techniques have been developed for defining internal transient and quasi-static blast overpressures (, ), pressure loads on the shield ( 2, 25, 26) and attenuated pressure... [Pg.55]

Fracture pressures are estimated from leak-off tests (LOT), where mud is pumped into the formation until the first evidence of fractures is detected. Leak-off pressure is the pressure at which the formation develops very thin fractures prior to rock failure. A great advantage of this kind of test is that it is an in situ test, thus we do not have to deal with relaxation or unloading problems. Fracture pressures estimated from LOT is in the range of 0.6-0.8 times the litho-static pressure, which is within the fracture pressure domain (0.7-0.9 lithostatic pressure) given by DuRouchet (1981). The overpressures do not reach fracture pressure (LOT) in any of the wells investigated. However, the pore pressure reaches 80% of... [Pg.204]


See other pages where Overpressure static is mentioned: [Pg.139]    [Pg.139]    [Pg.139]    [Pg.139]    [Pg.2323]    [Pg.2327]    [Pg.2328]    [Pg.168]    [Pg.561]    [Pg.15]    [Pg.18]    [Pg.359]    [Pg.134]    [Pg.35]    [Pg.765]    [Pg.155]    [Pg.230]    [Pg.2078]    [Pg.2082]    [Pg.2082]    [Pg.2083]    [Pg.443]    [Pg.260]   
See also in sourсe #XX -- [ Pg.46 ]