Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Orientation and Location

The first report of single molecule detection in an optical microscopy under ambient conditions was that of Betzig and Chichester [13]. The most striking aspect of their single molecule fluorescence images, reproduced in Fig. 3(a), is the variety of shapes. Except for the occasional photobleaching event which resulted in the disappearance [Pg.197]

Tetramethylrhodamine, Texas Red covalently linked to DNA, dried onto si lea 33 [Pg.198]

Rhodamine-phalloidin-labeled cytoskeletal actin cell, dried on silica 34 [Pg.198]

and (c) 210-270nm. Each panel shows two spectra taken about 5 min apart to show reproducibility. Zero detuning = 592.066 nm, the tip voltage, Vj = 0, and all traces are from the same sample. Adapted from Ref. 11. [Pg.201]

Stark effect. Molecules that displayed low power saturation also showed the largest Stark shifts, again indicating their close proximity to the probe. By examining the magnitude of the Stark shift, an estimate of the distance of the molecule from the tip was made, with an accuracy of about lOOnm. Finally, the tip was oscillated laterally with an amplitude of 20 nm creating a modulation of the Stark shift which could be used to determine the polar angle, 6, of the molecule to the tip axis. [Pg.201]


Figure 15.19 shows various crack orientations that can occur in connection and attachment welds. Applied stresses from external loading of these components can add to the residual weld stresses, producing still higher stress loads. This can increase the susceptibility to stress-corrosion cracking and can affect orientation and location of crack paths. [Pg.344]

Some of the factors involved in choosing a particular nondestructive evaluation technique are the primary reason or objective, the type of flaw to be detected, the size and orientation of the flaw, the location of the flaw in the sample, the size and shape of the sample and the nature of the sample. It is also necessary to know the type of flaws that are acceptable or unacceptable in the sense that flaws may be deleterious or nondeleter-ious. The size, type, orientation and location of the flaws determine whether they are acceptable or unacceptable as per the code, or standard given by American Society of Mechanical Engineers Pressure Vessel Code, American Welding Society Structural Welding Code or any other applicable code or standard. [Pg.126]

The EPR spectrum of the blue copper protein plastocyanin (Figure 3C) has gu > g > 2.00, and thus the copper site must have a dx2 y2 ground state. First, we are interested in determining the orientation of the dx2 y2 orbital relative to the distorted tetrahedral geometry observed in the protein crystal structure. Single crystal EPR spectroscopy allowed us to obtain this orientation and located the unique (i.e., z) direction in this distorted site (29). Plastocyanin crystallizes in an orthorhombic space group with four symmetry related molecules in the unit cell. The orientation of the plastocyanin copper sites in the unit cell are shown in... [Pg.135]

In these instances, the need for heavy atoms can be frequently side-stepped by performing a reciprocal space search in 6 dimensions - 3 rotational and 3 translational. For each point in this vast 6-dimensional space, the calculated Fourier amplitudes from the suitably rotated and translated model can be compared with the experimental Fourier amplitudes. Such an exhaustive search can in principle give the correct orientation and location of the available approximate model in the new crystal. This allows the calculation of approximate phases for the crystal structure and ultimately leads to an accurate atomic structure. However, such a molecular replacement solution does not always work. This is because in practice, a truly exhaustive 6-dimensional search is not possible given present day computing resource. So this 6-dimensional problem is routinely split into two far smaller and consecutive 3-dimensional problems - 3-dimensional... [Pg.284]

Discuss the principles of Fourier transform infrared spectroscopy and nonlinear laser optics [74, 75], and of second harmonic and sum frequency generation. Compare the relative advantages of both techniques for the study of the bonding, orientation, and location of adsorbed molecules either on metal or on insulator surfaces. [Pg.395]

The Cartesian co-ordinate system shown in Figure 22 is used to orientate and locate the measuring devices. The origin is located at the intersection of the tunnel axis and the contact plane between the concrete plug and the bentonite buffer. Positive X axis is directed along the tunnel axis towards the other end of the test section. The Z-axis is vertical, pointing upwards and the Y-axis is perpendicular to the (XZ) plane in the position indicated in Figure 22. [Pg.106]

K a multistation solution is chosen combined resection/ intersection can be advantageous to determine the coordinates of the observation stations and object points. Normally, however, overdetermined bundle solutions, based on least squares methods, are applied, to determine the orientation and location of the instruments together with the object points. [Pg.102]

Geometric dimensioning and tolerancing (GD T) is a symbolic language used to specify the size, shape, orientation, and location of part features. GD T is a concept widely used for specifying dimensions and tolerances of... [Pg.1230]

Laminar mixing is achieved by subjecting the polymer to permanent deformation involving shear, squeeze or elongational flow. In the melt-state, imposition of large strains is accompanied by an increase in the interfacial area between material and system. Laminar mixing is influenced strongly by the initial orientation and location of interfacial elements or additives [3]. [Pg.6]

The objective of the verification and validation activity is to ensure that the installed FGS system is in compliance with standards, and with the FGS specification having various performance parameters. There are two distinct phases. The first phase shall be a verification of installed equipment against the FGS requirements of specifications. During this phase, aU detectors will be viewed at the facility in order to verify that they are the correct type, and installed in the proper orientation and location as per specification. The second phase of this task will involve validation testing. The validation testing shall be accomplished by physically activating each detector by either simulating a fire with a fire simulator, and gas detectors with calibrated gas of tbe supplier. In each case, the audio-visual alarm, etc. is to be verified also. [Pg.537]

For motion of the whole molecule, however, it is the molecule s orientation and location in the laboratory that matters, and so we use the lab-fixed or space-fixed coordinates 0 and O to describe the orientation of the nuclei in the lab, and the coordinates X, Y, and Z, which pinpoint the center of mass of the molecule. [Pg.213]


See other pages where Orientation and Location is mentioned: [Pg.724]    [Pg.215]    [Pg.50]    [Pg.145]    [Pg.141]    [Pg.154]    [Pg.129]    [Pg.130]    [Pg.165]    [Pg.50]    [Pg.295]    [Pg.428]    [Pg.33]    [Pg.228]    [Pg.40]    [Pg.243]    [Pg.254]    [Pg.290]    [Pg.493]    [Pg.40]    [Pg.322]    [Pg.26]    [Pg.821]    [Pg.154]    [Pg.301]    [Pg.197]    [Pg.7]    [Pg.429]    [Pg.2078]    [Pg.412]    [Pg.556]    [Pg.125]    [Pg.135]    [Pg.418]    [Pg.199]    [Pg.133]    [Pg.633]   


SEARCH



© 2024 chempedia.info