Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Optimization multiplexer

Table 3 is the calculated area of the neural-recording system with various channel numbers and ADCs. As shown, the total chip area increases as the number of ADCs does, which is a straightforward conclusion. Therefore, there must be an optimal multiplexing ratio that makes the system s power-area product minimum. Table 4 is the power-area product based on Tables 2 and 3. From Table 4, we can deter-... [Pg.275]

PVD-coated screws for highly loaded silica compounds are mainly used in Berstorff Multiplex extmsion lines. With these lines, the different compounds are led together and shaped in special prohle extmsion dies. Flow channels with optimized geometry ensure a uniform material flow of the individual prohle components. The extmsion tools Berstorff developed for this purpose are... [Pg.1014]

Optimization of the flow paths of the multiplex head resulted in an additional reserve of capacity. The layout of the inlet angle of the extmders and the arrangement of the flow channels were made in such a way that necessitates the pressure loss to a miniumum. The benefit of this can be clearly seen in a reduced stock temperature. This lower temperature can be utilized to increase the throughput capacity. [Pg.1015]

As explained in depth in the next sections, most of the advanced high-resolution experiments on quadrupolar nuclei are based on the selection of specific coherences and on the transfer of these coherences along the selected pathways, which always terminate at the observable SQ coherence p = — 1. Most of the time, the selection is done using nested phase-cycling of the radiofrequency (rf) pulses included in the pulse sequence [34]. Recently, new methods have been proposed to optimize the nested phase-cycling procedure, including the schemes referred to as cogwheel [36-39] and multiplex [40—421. [Pg.128]

Huang D, Peng X, Su L, Wang D, Khuri FR, Shin DM, Chen Z (2010) Comparison and optimization of multiplexed quantum dot-based immunohistofluorescence. Nano Res 3 61-68... [Pg.39]

The number of multiplexed particles-based assays reported is manifold and summarized in several reviews [85, 86, 97, 99], Bead sets for various nucleic acid or protein assays are commercially available that are fully optimized for clinical diagnostics and research purposes. [Pg.217]

Control of the HPLC pump, the autosampler, and the MS is ensured by Masslynx 3.5 software. After optimization of the measurement conditions, a list of process measurements is setup (sample list), and the desired HPLC and MS steps are called upon. After a measurement, the ESI source is automatically brought to room temperature (shut down). Using 96-microtiter plates, 576 samples can be processed per measurement. The chromatograms are integrated by the software packages Quanlynx and Openlynx and exported as an Excel table. A macro is used to calculate the absolute intensities and therefore the ee and the conversion. The E values in kinetic resolution are automatically calculated with the formula of Sih [12]. Data processing is done with the Openlynx Browser. The overall process occurs continuously and enables analysis of up to 10000 samples per day, provided that the 8-channel multiplexed sprayer system is used [20b]. It is also possible to use 384-well micro titer plates. Systematic optimization is required for each new compound. [Pg.121]

The pattering process was optimized for leading a 400-nm thick MIP membrane and features were engraved by a 12-s UV exposure. Multiplexed chips were also successfully prepared using the same process and their features were spatially... [Pg.158]

The ideal assay system for HTS would include automated manipulation of single wells and each should be tested for a variety of activities simultaneously. One of the main challenges is to develop a simple assay sensitive enough to pick up enzyme activities that might be below their optimal level under the assay conditions. Nowadays novel colorimetric, luminescence, and fluorescence methods have been established in HTS with automated multiplex compound testing (typically 10-20 compounds per well) (Winson, 1997). [Pg.57]

In general, it is easier (and faster) to develop an HPLC-ESI-MS/MS method for multiple analytes with the matrix effects identified and under control as compared to IA (see below). Furthermore, selectivity and interference from matrix components and/or metabolites is less of a problem with an LC-MS/MS method compared to IA. With an appropriate internal standard (IS), LC-MS/MS methods are more precise than IA. Moreover, the LC-MS/MS calibration range is broader and can accommodate disproportionate concentration ranges of the drug compound and its metabolites. In contrast, most IA are geared to quantify only one analyte at a time because the method development of multiplex IA is complicated and often cannot be optimized for all analytes of interest. [Pg.162]

An advantage of the ASO method is that it can be used to simultaneously test samples for several different mutations by the use of multiple probes bound to a solid matrix. In practice, the success of this method relies on precisely establishing conditions for optimal oligonucleotide hybridization in order to ensure specific probe hybridization, and so multiplex ASO assays can be difficult to develop. Molecular diagnostic kits for use in genetic disorders based on ASO methods are available (14). [Pg.316]

The major reaction principles that form the basis of the genotyping technologies available today are primer extension, ligation, and hybridization. Many of the methods for SNP genotyping rely on PCR amplification of the sequence of interest prior to allele determination. Primer design and assay optimization for multiplexed and reproducible genotyping of SNPs in large sample sets have become major bottle necks in most methods used today. [Pg.342]

Novel sieving media and acceleration of electrophoretic runs coupled with suitable data processing are likely to provide excellent approaches to DNA sequencing by multiplexed CE. The technology can be readily scaled to 1024 capillaries, which is a convenient number for available array detectors. Such a system can be optimized to accelerate the sequencing process enormously. [Pg.261]


See other pages where Optimization multiplexer is mentioned: [Pg.463]    [Pg.412]    [Pg.80]    [Pg.272]    [Pg.463]    [Pg.412]    [Pg.80]    [Pg.272]    [Pg.141]    [Pg.396]    [Pg.149]    [Pg.249]    [Pg.140]    [Pg.262]    [Pg.284]    [Pg.26]    [Pg.420]    [Pg.116]    [Pg.89]    [Pg.261]    [Pg.124]    [Pg.216]    [Pg.146]    [Pg.177]    [Pg.205]    [Pg.162]    [Pg.174]    [Pg.217]    [Pg.309]    [Pg.310]    [Pg.348]    [Pg.354]    [Pg.362]    [Pg.362]    [Pg.363]    [Pg.363]    [Pg.365]    [Pg.365]    [Pg.629]    [Pg.630]    [Pg.391]    [Pg.112]   


SEARCH



Multiplex

Multiplex optimization

Multiplexing

© 2024 chempedia.info