Optical pumping apparatus

Finally, optical pumping and double resonance have opened the way to experiments where the species under study can be confined in closed resonance cells, whereas Rabi s technique relied on the spatial separation of atoms or molecules in a beam arrangement. Also, the new methods allowed the investigation of ions that cannot be studied with a Rabi-type apparatus. [Pg.5]

Takami and Shimoda extended their work with a similar apparatus to HDCO. In this particular experiment saturated absorption was used to detect signals in the ground as well as in the excited state with the same experimental arrangement. This work therefore demonstrates the similarities between double resonance and optical pumping and shows how easily... [Pg.14]

Fig.17.. Schematic diagram of the apparatus for a rubidium optical pumping experiment. Fig.17.. Schematic diagram of the apparatus for a rubidium optical pumping experiment.
The basic apparatus required for spin-exchange optical pumping is identical to that shown in Fig.17.2. The only... [Pg.616]

Fig.17.8 (a) Schematic diagram of apparatus used for optical pumping experiments in helium. (After Greenhow (1963).)... [Pg.617]

These limitations have recently been eliminated using solid-state sources of femtosecond pulses. Most of the femtosecond dye laser teclmology that was in wide use in the late 1980s [11] has been rendered obsolete by tliree teclmical developments the self-mode-locked Ti-sapphire oscillator [23, 24, 25, 26 and 27], the chirped-pulse, solid-state amplifier (CPA) [28, 29, 30 and 31], and the non-collinearly pumped optical parametric amplifier (OPA) [32, 33 and 34]- Moreover, although a number of investigators still construct home-built systems with narrowly chosen capabilities, it is now possible to obtain versatile, nearly state-of-the-art apparatus of the type described below Ifom commercial sources. Just as home-built NMR spectrometers capable of multidimensional or solid-state spectroscopies were still being home built in the late 1970s and now are almost exclusively based on commercially prepared apparatus, it is reasonable to expect that ultrafast spectroscopy in the next decade will be conducted almost exclusively with apparatus ifom conmiercial sources based around entirely solid-state systems. [Pg.1969]

Ultrafast TRCD has also been measured in chemical systems by incoriDorating a PEM into the probe beam optics of a picosecond laser pump-probe absorjDtion apparatus [35]. The PEM resonant frequency is very low (1 kHz) in these experiments, compared with the characteristic frequencies of ultrafast processes and so does not interfere with the detection of ultrafast CD changes. [Pg.2966]

Schematic diagrams of modem experimental apparatus used for IR pump-probe by Payer and co-workers [50] and for IR-Raman experiments by Dlott and co-workers [39] are shown in figure C3.5.3. Ultrafast mid-IR pulse generation by optical parametric amplification (OPA) [71] will not discussed here. Single-colour IR pump-probe or vibrational echo experiments have been perfonned with OP As or free-electron lasers. Free-electron lasers use... Schematic diagrams of modem experimental apparatus used for IR pump-probe by Payer and co-workers [50] and for IR-Raman experiments by Dlott and co-workers [39] are shown in figure C3.5.3. Ultrafast mid-IR pulse generation by optical parametric amplification (OPA) [71] will not discussed here. Single-colour IR pump-probe or vibrational echo experiments have been perfonned with OP As or free-electron lasers. Free-electron lasers use...
Figure 1. Apparatus for the preparation of radical anions (11). On connection of the entire vessel to the vacuum system, traces of water and oxygen on the wall are removed by heating and discharging with a tesla coil. When the apparatus is filled with purified nitrogen through A, the weighed sample of the hydrocarbon is put into B through C, a piece of sodium is put into D, and dimethoxyethane is distilled into E, where a small amount of an Na-K alloy is added. After the system is again evacuated the solvent is distilled from E into B, the bulb E is,sealed off at F, and the sodium is sublimed to form a mirror on the wall of the bulb G. After tubes at C and H are sealed off, the apparatus is pumped to high vacuum for 1 hr and then sealed off at J. Then the solution of the hydrocarbon is poured from B into G. After a time varying from several minutes to several hours, a color is observed, and the sample is ready for optical and esr measurements. Figure 1. Apparatus for the preparation of radical anions (11). On connection of the entire vessel to the vacuum system, traces of water and oxygen on the wall are removed by heating and discharging with a tesla coil. When the apparatus is filled with purified nitrogen through A, the weighed sample of the hydrocarbon is put into B through C, a piece of sodium is put into D, and dimethoxyethane is distilled into E, where a small amount of an Na-K alloy is added. After the system is again evacuated the solvent is distilled from E into B, the bulb E is,sealed off at F, and the sodium is sublimed to form a mirror on the wall of the bulb G. After tubes at C and H are sealed off, the apparatus is pumped to high vacuum for 1 hr and then sealed off at J. Then the solution of the hydrocarbon is poured from B into G. After a time varying from several minutes to several hours, a color is observed, and the sample is ready for optical and esr measurements.
The apparatuses used for the studies of both ammonia synthesis emd hydrodesulfurization were almost identical, consisting of a UHV chamber pumped by both ion and oil diffusion pumps to base pressures of 1 x10 " Torr. Each chamber was equipped with Low Energy Electron Diffraction optics used to determine the orientation of the surfaces and to ascertain that the surfaces were indeed well-ordered. The LEED optics doubled as retarding field analyzers used for Auger Electron Spectroscopy. In addition, each chamber was equipped with a UTI 100C quadrupole mass spectrometer used for analysis of background gases and for Thermal Desorption Spectroscopy studies. [Pg.155]

More recently Ghiggino and co-workers(32) have applied laser scanning confocal fluorescence lifetime microscopy to the study of polyvinyl alcohol films containing rhodamine B (650 nm emission) and cresyl violet (632 nm emission). Synchronously pumped dye laser excitation and APD detection were used with optical fiber coupling. A schematic diagram of their apparatus is shown in Figure 12.5. [Pg.385]


See other pages where Optical pumping apparatus is mentioned: [Pg.626]    [Pg.626]    [Pg.250]    [Pg.474]    [Pg.36]    [Pg.380]    [Pg.931]    [Pg.439]    [Pg.931]    [Pg.206]    [Pg.429]    [Pg.237]    [Pg.250]    [Pg.269]    [Pg.579]    [Pg.591]    [Pg.9]    [Pg.11]    [Pg.17]    [Pg.27]    [Pg.109]    [Pg.577]    [Pg.616]    [Pg.1973]    [Pg.1979]    [Pg.3039]    [Pg.377]    [Pg.379]    [Pg.714]    [Pg.130]    [Pg.443]    [Pg.461]    [Pg.10]    [Pg.372]    [Pg.157]    [Pg.26]    [Pg.573]    [Pg.230]   