Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

MS model

Tsiatis AA, DeGruttola V, Wulfsohn MS. Modeling the relationship of survival to longitudinal data measured with error. Applications to survival and CD4 counts in patients with AIDS. / Am Stat Assoc 1995 90 27-37. [Pg.307]

For some MS models and brands it is recommended that all three types of calibration are performed so that any mode of data acquisition can be used and mass ranges and scan speeds can be changed while maintaining correct mass assignment [5]. Some other instruments calibrate all together without distinctions [6-8]. When the instrument is fully calibrated, any mass range or scan speed is allowed within the upper and lower limits dictated by the calibrations. [Pg.209]

S. D. Tanner, Ion optics for ICP-MS modelling intuition or blind luck, in Plasma Source Mass Spectrometry Development and Applications, ed. G. Holland and S. D. Tanner, Royal Society of Chemistry, Cambridge, 1997, pp. 13. [Pg.48]

Figure 8.6. Representative configuration of LC with postcolumn flow passively split to EC-Array and MS. Model 6210 EC cells were controlled with a 16-channel CoulArray (ESA Biosciences, Chelmsford, MA). (Reprinted with permission from Gamache et at., 2004b.)... Figure 8.6. Representative configuration of LC with postcolumn flow passively split to EC-Array and MS. Model 6210 EC cells were controlled with a 16-channel CoulArray (ESA Biosciences, Chelmsford, MA). (Reprinted with permission from Gamache et at., 2004b.)...
Peaks identified penta-O-methyl-mono-O-acetylmyoinositol derived from mono-linked myoinositol, 2,3,6-tri-O-methyl-1,4,5-tri-O-acetylglucitol derived from a 4-linked glucose, and 3,4,6-tri-O-methyI-l, 5,di-0-aeetyl-2-acetamido-2-N-methylglucitol derived from a terminal H-acetylglucosamine. The PMAA sample was chromatographed on a 1.5 m X 2 mm ID column packed with 3% OV-210 in a Finnigan automated GC/MS model 3300/6110. Temperature program 150° to 215°C at 6°C/min. [Pg.69]

OLEDs), where contact resistance is a crucial issue too. Ultraviolet photoelectron spectroscopy (UPS) and inverse UPS have been used to precisely determine the energy levels at both sides of the interface [45], A typical result for the Au-pentacene interface is shown in Figure 2.2.16, which clearly shows that the actual interface strongly deviates from the MS model. [Pg.95]

High mass-spectral resolution is often essential in structural work as the answers obtained with conventional low-resolution instruments may not always be unequivocal in terms of atomic composition in the studied molecules. While the resolution obtained in a GC/MS model on the individual chromatographic peaks is short of the typical values obtained under static conditions, it is frequently sufficient to yield the exact molecular weights. Due to the design features of double-focusing instruments, sensitivities are typically lower than those obtained with the conventional GC/MS instruments. [Pg.82]

DMoP www.accelrys.com/mstudio/ ms modeling/dmoH.html 286... [Pg.105]

Fig. 1. Chromatogram of fresh Mimusop elengi flower. GC system Column TR-5 (5%phenyl-95%dimethylpolysiloxane), 30m, 0.25 am, 0.25 mm ID Oven temperature program 60 °C to 180 C at 3 °C.min-i, to 280°C.min-i at 10 °C.min-i (hold 5 min) Run time 55.00 min Carrier gas flow rate (Helium) 1 ml/min Transfer line temperature (Interface temp.) 275 °C Ion source 220 C. Scan mode full scan 35-650 m/z Scan rate 2000amu/s Solvent delay time 3min. Instrument TraceGC ultra. Model K05200B20000070, Italy/MS Model TraceDSQ,USA Software Xcalibur 1.4 Library NIST MS Search... Fig. 1. Chromatogram of fresh Mimusop elengi flower. GC system Column TR-5 (5%phenyl-95%dimethylpolysiloxane), 30m, 0.25 am, 0.25 mm ID Oven temperature program 60 °C to 180 C at 3 °C.min-i, to 280°C.min-i at 10 °C.min-i (hold 5 min) Run time 55.00 min Carrier gas flow rate (Helium) 1 ml/min Transfer line temperature (Interface temp.) 275 °C Ion source 220 C. Scan mode full scan 35-650 m/z Scan rate 2000amu/s Solvent delay time 3min. Instrument TraceGC ultra. Model K05200B20000070, Italy/MS Model TraceDSQ,USA Software Xcalibur 1.4 Library NIST MS Search...
Waghmare UV, Kaxiras E, Duesbeiy MS. Modeling Brittle and Ductile behavior of solids from first-principles calculations. Phys. Status Solidi B 2000 217 545-564. [Pg.248]

One can use accident theories and accident sequence models presented earlier in this chapter to help formulate accident prevention strategies. For example, one can apply Haddon s energy theory to prevent accidents and reduce their consequences or one can apply the 4 Ms model to help think through the elements that may lead to accidents in particular situations. [Pg.30]

Identify hazards in your place of work or residence, applying the four Ms model and the goal accomphshment model. [Pg.99]

Figure 2.2 The total resistivity of Si02/Cu/Si02 and Si02/Ta/Cu/Ta/Si02 lines as a function of thickness (a) and Cu grain size (h). The symbols are experimental data and the solid curves are plots of FS and MS models, respectively. Figure 2.2 The total resistivity of Si02/Cu/Si02 and Si02/Ta/Cu/Ta/Si02 lines as a function of thickness (a) and Cu grain size (h). The symbols are experimental data and the solid curves are plots of FS and MS models, respectively.
Figure 2.3 The total resistivity as a function of linewidth at various grain size values for the combined FS—MS model. Figure 2.3 The total resistivity as a function of linewidth at various grain size values for the combined FS—MS model.
Relative density (p/p versus reduced time for Mackenzie-Shuttleworth model (solid curve) and cylinder model (dashed curve). For p/p > 0.942, the MS model applies. The curves have been shifted to coincide at the time t when sintering is complete. From Scherer 128). [Pg.351]

In Eqs. 23 and 24, Xg and yg are initial values in Eq. 25, a = (8V2) . Equation 24 is plotted as the dashed curve in Fig. 7. In view of the profound difference in the structure, the densification curve is surprisingly close to that found by Mackenzie and Shuttleworth [24], As the cylinder model densifies, the cylinders become shorter and thicker and, when the relative density reaches p 0.94, neighboring cylinders touch. At that point, the unit cell contains an isolated pore, so the remainder of the densification is described by the MS model. ... [Pg.352]

Relative density versus reduced time for sintering of close-packed spheres shown in Fig. 17B, using MS model (A) and cylinder model (B). From Sacks and Tseng [48], reprinted by permission of the American Ceramic Society. [Pg.358]

ICP-MS was slow to adopt multipole ion optics, despite their routine use in organic mass spectrometry for some considerable time. Commercial ICP-MS models have to date employed the quadrupole and higher order multipoles such as the hexapole and octopole as gas pressurised collision cells/unpressurised ion guides. A photograph of an exposed hexapole assembly is shown in Figure 1.9. The unit comprises six highly polished rods with a circular profile, held parallel in an accurately machined ceramic former, effectively forming a tube. [Pg.22]

The amorphous packing model construction and the atomistic simulations of the shown polymers have been investigated using Accelrys Materials Studio (MS) Modeling... [Pg.155]


See other pages where MS model is mentioned: [Pg.120]    [Pg.279]    [Pg.6]    [Pg.281]    [Pg.51]    [Pg.19]    [Pg.115]    [Pg.445]    [Pg.94]    [Pg.1163]    [Pg.346]    [Pg.465]    [Pg.235]    [Pg.14]    [Pg.99]    [Pg.346]    [Pg.29]    [Pg.281]    [Pg.435]    [Pg.436]    [Pg.365]    [Pg.352]    [Pg.59]    [Pg.171]    [Pg.155]    [Pg.156]   


SEARCH



A Model for m-LPPP Electronic Structure

Animal Models of MS

Building confidence in the mathematical models by calibration with a T-H-M field experiment

M-diffusion model

Models of MS

© 2024 chempedia.info