Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mounting conductors

Surface mount technology is being used increasingly in assemblies such as in-car telephones and audio equipment. PBT and PET, more stable dimensionally than PA 66, are widely used. Distributorless ignition systems (DIS), for example, use a tray in PBT, with surface mounted conductors, filled with epoxy and encapsulated with PET. Vapour phase soldering can involve temperatures of up to 260°C for several seconds. This is encouraging the use of fully aromatic polymers like PPS and PEI, which not only have a high HDT but are also inherently non-flammable. [Pg.155]

Surface mount refers to a method of securing connectors to the conductors of a printed circuit board by soldering appropriately shaped contacts to the board surface. Higher contact densities can be achieved and the need to drill holes in the board is avoided. Contact spacings may vary from about 0.5 cm for large current-carrying appHcations to 0.18 cm or less when miniaturization and high density is a requirement. [Pg.25]

To delermine ihe minimum size of current-carrying conductors and decide on the mounting arrangement). [Pg.864]

The electric field produced by the current-carrying conductors of each phase also links the metallic bus enclosure, its mounting supports, and structures existing in the vicinity, parallel and around the axis of the current-carrying conductors. It causes induced (parasitic) currents in such structures and leads to the following ... [Pg.887]

Insulators The conductors are resilient mounted on post insulators, to hold them in the centre (Figure 31.3) and dampen the forces, during normal operation or on fault. The conductors are held in position to have free movement axially but they have almost no movement... [Pg.931]

Precautions in mounting insulators and conductors Making a joint Bending of busbars... [Pg.998]

Figure 21-1 shows the object to be protected and the arrangement of impressed current anodes and reference electrodes. A central anode and two ring anodes of platinized titanium wire 3 mm in diameter provided with additional copper wire conductors are installed here. It is worth noting that the central anode is suspended from a float, whereas the ring anode is mounted on plastic supports. The zinc reference electrodes are also on floats near the inner side of the bell, while the 17 reference electrodes are mounted on plastic rods on the bottom of the cup and in the ring... [Pg.468]

A classical setup for microwave conductivity measurements is based on the utilization of the waveguides. A simple installation consists of a microwave generator (typically a gun diode) which, when the Ka-band is used, can be operated in the frequency region of 28-40 Gc/s this is protected by an isolator against back-reflections from the rest of the microwave circuit. The microwave power is conducted by an attenuator across a circulator into the microwave conductor branch at the end of which the electrochemical cell is mounted. The microwave power reflected from the electrochemical sample is conducted via the circulator into the microwave detector. It typically consists of a diode that acts as an antenna, receiving the electrical alternating field, rectifying it, and con-... [Pg.446]

In general, the physical state of the electrodes used in electrochemical processes is the solid state (monolithic or particulate). The material of which the electrode is composed may actually participate in the electrochemical reactions, being consumed by or deposited from the solution, or it may be inert and merely provide an interface at which the reactions may occur. There are three properties which all types of electrodes must possess if the power requirements of the process are to be minimized (i) the electrodes should be able to conduct electricity well, i.e., they should be made of good conductors (ii) the overpotentials at the electrodes should be low and (iii) the electrodes should not become passivated, by which it is meant that they should not react to form on their surfaces any compound that inhibits the desired electrochemical reaction. Some additional desirable requirements for a satisfactory performance of the cell are that the electrodes should be amenable to being manufactured or prepared easily that they should be resistant to corrosion by the elements within the cell that they should be mechanically strong and that they should be of low cost. Electrodes are usually mounted vertically, and in some cases horizontally only in some rare special cases are they mounted in an inclined manner. [Pg.696]

We should not think that heat is lost only from the copper side. The usual laminate (board material) used for SMT (surface mount technology) applications is epoxy-glass FR4, which is a fairly good conductor of heat. So some of the heat from the side on which the device is mounted does get across to the other side, where it contacts the air and helps reduce the thermal resistance. Therefore, just putting a copper plane on the other side also helps, but only by about 10 to 20%. Note that this opposite copper plane need not even be electrically the same point it could for example just be the usual ground plane. A much greater reduction of thermal resistance (by about 50 to 70%) can be produced if a cluster of small vias (thermal vias) are employed to conduct the heat from the component side to the opposite side of the PCB. [Pg.155]

In SFM, the probe tip is mounted on a highly sensitive, cantilever-type spring. The force of interaction between the sample and the tip can be calculated from the spring constant and the measured deflection of the cantilever. The deflection is sensed using the STM principle (Vignette 1.8) or capacitance or optical methods. The SFM can be operated in the contact regime or like the SFA. In the latter mode, one can measure van der Waals forces (see Chapter 10), ion-ion repulsion forces (see Chapter 11), and capillary forces and frictional forces, among others. In contrast to STM, the SFM can be used for both conductors and... [Pg.55]

In a second embodiment the strip detectors A to H are mounted on an intrinsic p-type silicon substrate 3A covered by a silicon oxide layer 3B. A patterned arrangement of conductor tracks 21 is formed in the semiconductor base 3B. Each track is formed by diffusion or ion-implantation of an n-type dopant material, and isolated from adjacent tracks by means of a channel stop network 23. Bridging links of nichrome-gold are formed to define and connect the read-out regions to the tracks 21. The links 25 are paired and thus provide voltage detection contacts. The tracks 21 are connected to connection pads 29. Signal processing circuitry is incorporated in the semiconductor base layer 3B. [Pg.32]

An HgCdTe imager chip 130 and Si read-out chips 140 are mounted on a substrate. The imager chip is connected to the read-out chips by an interconnect structure ISO in which a layer 152 of dielectric material is bonded to the chips and has interconnecting conductors disposed thereon and extending through via holes therein into ohmic contact with contact pads of the chips. A flexible portion in the structure enables the read-out and the imager chips to be disposed in different planes to provide a compact structure. [Pg.121]

For testing convenience the device was mounted on a microscope stage in which the recording laser beam is focused from below through the glass substrate, as shown in Fig. 20a. This allows the recording surface to be directly observed from above. Since both the polymer and the top conductor are semitransparent, the performance is comparable to that obtained if the laser beam illuminates the photoconductor from the top surface. [Pg.204]

Sensor. The control of the exhaust composition was essential to maintain the air-to-fuel ratio close to stoichiometric for simultaneous conversion of all three pollutants. This control came about with the invention of the 02 sensor.21,22 The sensor head of this device was installed in the exhaust immediately at the inlet to the catalyst and was able to measure the 02 content instantly and precisely. It generates a voltage consistent with the Nemst equation in which the partial pressure of 02 (P02)exhaust in the exhaust develops a voltage (E) relative to a reference. The exhaust electrode was Pt deposited on a solid oxygen ion conductor of yttrium-stabilized zirconia (Zr02). The reference electrode, also Pt, was deposited on the opposite side of the electrolyte but was physically mounted outside the exhaust and sensed the partial pressure (P02)ref in the atmosphere. E0 is the standard state or thermodynamic voltage. R is the universal gas constant, T the absolute temperature, n the number of electrons transferred in the process, and F the Faraday constant. [Pg.293]

Type of protection EEx dl Certificate INERIS 95.D.7027X Rated voltage 1100 V 3 AC Rated current 450 A Cable conductor cross-section up to 185 mm2 Auxiliary contacts 4 mm2 Cable conductor cross-section 6 mm2 (Top to bottom) two plugs for different cable diameters socket with mounting flange longitudinal section of a plug. [Pg.303]


See other pages where Mounting conductors is mentioned: [Pg.441]    [Pg.524]    [Pg.532]    [Pg.23]    [Pg.432]    [Pg.547]    [Pg.864]    [Pg.869]    [Pg.879]    [Pg.888]    [Pg.903]    [Pg.905]    [Pg.942]    [Pg.950]    [Pg.957]    [Pg.291]    [Pg.51]    [Pg.122]    [Pg.178]    [Pg.176]    [Pg.330]    [Pg.44]    [Pg.369]    [Pg.441]    [Pg.23]    [Pg.451]    [Pg.478]    [Pg.317]    [Pg.320]    [Pg.76]    [Pg.289]    [Pg.795]    [Pg.357]    [Pg.512]   
See also in sourсe #XX -- [ Pg.905 ]




SEARCH



Mount

© 2024 chempedia.info