Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pumps and Motors

Its function is to absorb the vibrations generated by the motor and pump. [Pg.148]

The drive motor and pump are enclosed in a single casing and the stator windings and armature are protected by metal cans they are usually referred to as canned pumps. The motor runs in the process fluid. The use of canned pumps to control environmental pollution is discussed by Webster (1979). [Pg.216]

For many years the connection between the pump and motor was made with a V-belt, but direct-drive pumps are becoming common. The latter are more compact, smoother running, and perhaps a bit quieter and more reliable. On the other hand, the semiflexible coupler between the motor and pump shaft can... [Pg.66]

Currently, the motor section of the direct-drive pump is connected to the pump section by a coupling. This coupling allows acceptable variations in alignment between the motor and pump, but each component independently maintains their own tight tolerances. [Pg.346]

E = efficiency of motor and pump expressed as a fraction B = a constant independent of Dt... [Pg.363]

E = efficiency of motor and pump expressed as a fraction f = Fanning friction factor, dimensionless, or function for dynamic programming in Eq. (91) indicating optimum return depends on that input... [Pg.413]

IV. Transportation, Material Handling and Treating, Motor and Pump, and... [Pg.203]

IV Weapons, Transportation, Materials Handling and Treating, Motors and Pumps V Miscellaneous... [Pg.66]

Note The above numbers presume a 90%-92% efficient motor and a pump head isentropic efficiency of 40%. These efficiencies are critical to selecting the proper cooling approach and will be validated by testing by the motor and pump head design. ... [Pg.506]

Polybutadiene is also produced in low volume as specialty products. These include low-molecular-weight, liquid 1,2-polybutadienes (60-80%, 1,2 content) used as potting compounds for transformers and submersible electric motors and pumps, liquid trans-1,4-polybutadienes used in protective coatings inside metal cans, and hydroxy-terminated polybutadiene liquid resins for use as a binder and in... [Pg.411]

Astumian RD, Doenyi I (1998) Fluctuation driven transport and models of molecular motors and pumps. Eur Biophys J 27 474—489... [Pg.315]

Stores and supplies. Central Facilities will furnish janitorial and office supplies standard spare parts such as small motors and pumps fabrication materials such as lumber, steel, and nonferrous metals and operating supplies such as fuel oil, gas cylinders, acids, and caustic. [Pg.31]

The motor and pump shaft or bearings and coupling will withstand any combination of normal operating loads or anticipated transients, and the largest remaining pipe break after application of leak before break as described in Section 3.6, combined with the Safe Earthquake Shutdown. [Pg.129]

Independent hydraulic motor and pump charge an accumulator building injection pressure to 20,000 psi... plenty of "push" for engineering materials. [Pg.332]

Referring to Fig. V/3.1.5-1, one may note that there is validation for a correct failure path. In the aforementioned example, it is seen that AB is not really a valid failure path in the sense that if motor and pump fail, then a top event will not occur. As mentioned earlier, the fault tree is evaluated by transforming it into an equivalent set of logic equations where such an invalid path will not occur. In order to understand how a fault tree is transformed into an equivalent set of logic equations, and cut sets are determinted, refer to Fig. V/3.1.5-2. [Pg.331]

Reactor coolant pumps - The IRIS RCPs [12] are of a spool type, which has been used in marine applications, and are being designed and will soon be supplied for chemical plant applications requiring high flow rates and low developed head. The motor and pump consist of two concentric cylinders, where the outer ring is the stationary stator and the... [Pg.57]

Here n is the number of moles and R is the universal gas constant. The temperature term T needs no subscript because the temperature is constant. The motor and pump driving... [Pg.273]

During the past two years Pesco has been quite active in constructing and testing various types of pumps for a number of cryogenic fluids, Some preliminary tests in both liquid nitrogen and liquid hydrogen on much smaller motors and pumps than those to be shown were made through the aid of NACA in Cleveland. [Pg.241]

Many appliance applications for adhesives are those adhesives used in the electrical industry for the assembly of motors and pumps. [Pg.64]

Example 1. Fig. 2 depicts a DFT representing a cardiac assist system (CAS) [9] consisting of three subsystems the CPU, the motor and pump units. If either one of these subsystems fails, then the entire CAS fails, as modelled by the top level OR gate. The CPU unit consists of a primary (P) and a backup (B) CPU, as indicated by the SPARE gate. The primary and backup CPU are subject to a common cause failure, modelled by the CPU FDEP gate if either the crossbar... [Pg.295]

XI.6.3 Fluidity Temperature Test Bath consists of a reservoir, a stirrer, and a motor and pump to circulate coolant through the coils of the tubing placed in the bottom of the test bath and passing through the cold bath. The flow of coolant through these coils can be controlled by a thermostat and a solenoid valve. It is possible that, where... [Pg.90]

Figure 3.13 Pelton turbine connected to RO train motor and pump. Figure 3.13 Pelton turbine connected to RO train motor and pump.

See other pages where Pumps and Motors is mentioned: [Pg.520]    [Pg.422]    [Pg.190]    [Pg.578]    [Pg.316]    [Pg.148]    [Pg.589]    [Pg.99]    [Pg.413]    [Pg.12]    [Pg.314]    [Pg.760]    [Pg.356]    [Pg.68]    [Pg.122]    [Pg.330]    [Pg.187]    [Pg.109]    [Pg.218]   
See also in sourсe #XX -- [ Pg.356 , Pg.357 ]




SEARCH



Pump and Motor Purchase Costs

Pump and motor speed

Pumps and Pumping

© 2024 chempedia.info