Minimum ventilation requirements

Minimum ventilation requirements The lowest possible airflow rates that will ensure all obnoxious products are removed from the air by the introduction of fresh air. [Pg.1459]

In many instances the chemical operator has only to switch the fan or fans on or off as required. Care should be taken to avoid blocking the open ends of the ducts and to use the control dampers, where supplied, to give the minimum ventilation required. This enables more draught to be concentrated in areas which may require it. It is pointless to have all dampers fully open all the time. [Pg.137]

How are these equations used Let us consider a propane-powered forklift truck that is operating in a warehouse and producing 2.0 g/min carbon monoxide. The industrial hygiene standard for carbon monoxide is 35 ppm. What is the minimum ventilation rate required for the warehouse to ensure safe working conditions To convert the mass of CO per minute to a volume, we can assume conditions of 1 atm pressure, 20°C. [Pg.54]

Ventilation Ventilation systems have served as the primary and supplementary sources of control for reducing miners imderground exposures to toxic air pollutants. Dilution ventilation supplemented with other types of controls should be used to reduce exposure to diesel emissions. As a minimum, ventilation rates must meet statutory and regulatory requirements for imderground mines. [Pg.320]

The use of underground mining methods requires integration of transportation, ventilation, ground control, and mining methods to form a system that provides the highest possible degree of safety, the lowest cost per ton of product, the most suitable quality of final product, the maximum possible recovery of coal, and the minimum disturbance of... [Pg.259]

Small areas Ventilate to remove the vapors. If condensation is present, decontaminate with copious amounts of undiluted household bleach (see Section 4.5.3.1). Allow it to stand for a minimum of 5 minutes before rinsing with water. Collect and place into containers lined with high-density polyethylene. Wash the area with copious amounts of soap and water. Collect and containerize the rinseate. Removal of porous material, including painted surfaces, may be required because vesicants that have been absorbed into these materials can migrate back to the surface posing both a contact and vapor hazard. [Pg.197]

Temperature and humidity are controlled to ensure worker comfort and product quality. When excessive exhaust occurs, the supply system would need to supply more outside air than the minimum required for proper ventilation, resulting in more heating and cooling energy. [Pg.251]

Commonly odour samples are taken in the morning, process conditions noted, and air flow rates, temperatures etc measured, followed in the afternoon by the odour strength measuring session. Odour strengths can vary greatly with process conditions, ventilation rates and production procedures and each sample is essentially only a snapshot picture . Therefore even with a rapid method of odour assessment, the total number of odour samples may be no more than the acceptable minimum required to investigate a particular factory or farming situation... [Pg.70]

With respect to ventilation systems, we employ standard design criteria for volume flow rate, negative pressure, and face velocity requirements in contaminated and potentially contaminated areas. In contaminated plant areas, we employ a minimum of 20 air changes per hour, while in clean operating areas we use a minimum of 6 air changes per hour. All entries to the contaminated areas incorporate airlocks to prevent migration into the clean areas. [Pg.325]

This adhesive is a resin/solvent adhesive material compounded to supply satisfactory initial tack. The solvent system has been carefully selected for somewhat rapid evaporation, thereby requiring minimum temperature and ventilation. Useful in textiles and paper board industries. [Pg.292]

When designing a local exhaust ventilation system for a process that generates dust particles, it is important to consider the minimum air velocity. The minimum air velocity is the velocity required to prevent settling of dust particles in the air ducts. The minimum velocity is a function of dust particle size and particle density. Listed in the table below are the minimum air velocities recommended for the transport of various types of particulate contaminants. [Pg.818]


See other pages where Minimum ventilation requirements is mentioned: [Pg.134]    [Pg.164]    [Pg.134]    [Pg.164]    [Pg.195]    [Pg.408]    [Pg.223]    [Pg.65]    [Pg.330]    [Pg.54]    [Pg.108]    [Pg.27]    [Pg.360]    [Pg.219]    [Pg.414]    [Pg.1122]    [Pg.478]    [Pg.105]    [Pg.247]    [Pg.15]    [Pg.152]    [Pg.197]    [Pg.227]    [Pg.16]    [Pg.131]    [Pg.75]    [Pg.360]    [Pg.244]    [Pg.245]    [Pg.108]    [Pg.626]    [Pg.637]    [Pg.414]    [Pg.165]    [Pg.341]    [Pg.252]    [Pg.360]    [Pg.479]    [Pg.134]    [Pg.2518]   
See also in sourсe #XX -- [ Pg.1460 ]