Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

MIEC mixed ionic/electronic

Figure 12.10 Various configurations of anodes. MIEC = mixed ionic electronic conductor Cermet — ceramic-metal mixture. Figure 12.10 Various configurations of anodes. MIEC = mixed ionic electronic conductor Cermet — ceramic-metal mixture.
The process that is the subject of this article consists of the use of high temperature ceramic membranes that selectively transport oxygen. They are referred to with several acronyms of which ITM (Ion Transport Membranes), OTM (Oxygen Transport Membranes) and MIEC (Mixed Ionic Electronic Conducting) membranes prevail. We will use ITM throughout this article. [Pg.29]

Solids are mixed conductors that means electronic and ionic charge carriers show mobility in the lattice. One speaks of preferential ionic condnctivily if the electronic transference nnmber is t <0.01. The electronic condnctivity increases exponentially with the temperature and, for oxides, depends on the partial pressnre of oxygen. Materials with preferential ionic condnctivity can be found only in a certain temperature and pressure region. Materials with comparable ionic as well as electronic conductivity are called MIECs (mixed ionic electronic conductors). These materials have become especially interesting for applications. As an example, the ratio of electronic conductivity to ionic conductivity... [Pg.24]

MA-CLR Membrane assisted-chemical looping refomiing MIEC Mixed ionic-electronic conducting... [Pg.96]

Solid mixed ionic-electronic conductors (MIECs) exhibit both ionic and electronic (electron-hole) conductivity. Naturally, in any material there are in principle nonzero electronic and ionic conductivities (a i, a,). It is customary to limit the use of the term MIEC to those materials in which a, and 0, 1 do not differ by more than two orders of magnitude. It is also customary to use the term MIEC if a, and Ogi are not too low (o, a i 10 S/cm). Obviously, there are no strict rules. There are processes where the minority carriers play an important role despite the fact that 0,70 1 exceeds those limits and a, aj,i< 10 S/cm. In MIECs, ion transport normally occurs via interstitial sites or by hopping into a vacant site or a more complex combination based on interstitial and vacant sites, and electronic (electron/hole) conductivity occurs via delocalized states in the conduction/valence band or via localized states by a thermally assisted hopping mechanism. With respect to their properties, MIECs have found wide applications in solid oxide fuel cells, batteries, smart windows, selective membranes, sensors, catalysis, and so on. [Pg.436]

D Mixed ionic electronic conductor (MIEC) o Triple-phase boundaries (TPB s)... [Pg.243]

Figure 15.1. Illusuation of the difference in location of the electrode reaction on two different SOFC electrode types. Upper In an electrode where the electrode material is exclusively an electronic conductor, the reaction zone is restrained to the vicinity of the triple phase boundary (TPB). Lower In a mixed ionic-electronic conductor (MIEC) the electrode reaction can take place on the entire electrode surface... Figure 15.1. Illusuation of the difference in location of the electrode reaction on two different SOFC electrode types. Upper In an electrode where the electrode material is exclusively an electronic conductor, the reaction zone is restrained to the vicinity of the triple phase boundary (TPB). Lower In a mixed ionic-electronic conductor (MIEC) the electrode reaction can take place on the entire electrode surface...
It is obvious that a highly permeable membrane material must exhibit large con-ductivies for both ionic and electronic charge carriers. Partial conductivities of various, so-called mixed ionic electronic conductors (MIEC), as calculated or directly obtained from Refs. 9-21, are presented in Figure 2. [Pg.181]

The use of mixed ionic-electronic conductors (MIECs) as ORR electrocatalysts is quite common in solid-state electrochemistry [125], because the reaction zone is extended over the entire electrode/gas interface, contrary to the case of metal electrodes where the reaction is, to a large extent, restricted to the tpb zone [23]. [Pg.62]

In this section, a brief overview is given of major membrane concepts and materials. Besides membranes made from a mixed ionic-electronic conductor (MIEC), other membranes incorporating an oxygen ion conductor are briefly discussed. Data from oxygen permeability measurements on selected membrane materials are presented. [Pg.436]

Ceramic electrochemical reactors are currently undergoing intense investigation, the aim being not only to generate electricity but also to produce chemicals. Typically, ceramic dense membranes are either pure ionic (solid electrolyte SE) conductors or mixed ionic-electronic conductors (MIECs). In this chapter we review the developments of cells that involve a dense solid electrolyte (oxide-ion or proton conductor), where the electrical transfer of matter requires an external circuitry. When a dense ceramic membrane exhibits a mixed ionic-electronic conduction, the driving force for mass transport is a differential partial pressure applied across the membrane (this point is not considered in this chapter, although relevant information is available in specific reviews). [Pg.397]

Sunarso J, Baumann S, Serra JM, Meulenberg WA, Liu S, Lin YS, and Diniz da Costa JC. Mixed ionic-electronic conducting (MIEC) ceramic-based membranes for oxygen separation. J. Membr. Sci. 2008 320 13-41. [Pg.255]

Key words membrane reactor, perovskite, proton conducting membrane, mixed ionic-electronic conductor (MIEC), partial oxidation of methane... [Pg.347]

Figure 3.2 Schematic illustration of oxygen permeation through mixed ionic-electronic conducting (MIEC) membranes when air is used as the feedstock stream (Zhu Yang, 2011). Reprinted with permission hy Elsevier. Figure 3.2 Schematic illustration of oxygen permeation through mixed ionic-electronic conducting (MIEC) membranes when air is used as the feedstock stream (Zhu Yang, 2011). Reprinted with permission hy Elsevier.
Despite the apparent simplicity of this reaction, the process by which the oxygen reduction occurs followed by incorporation of the ionic species into the electrolyte is the subject of some debate and is dependent on the mode of operation of the cathode material. Two typical cathode types are currently utilized in SOFCs -electronic conductors and mixed ionic-electronic conductors (MIECs). The cathode reactions, while nominally the same in both types of materials, occur at different locations, and hence, the active region varies, leading to differences in the operating regime and ultimately performance. In the case of a single phase electronic conductor. [Pg.1008]

Sunarso J, Mixed Ionic-electronic Conducting (MIEC) Ceramic-based Membranes for Oxygen Separation, Journal of Membrane Science, 320,13-41 (2008). [Pg.101]


See other pages where MIEC mixed ionic/electronic is mentioned: [Pg.742]    [Pg.320]    [Pg.320]    [Pg.513]    [Pg.337]    [Pg.916]    [Pg.275]    [Pg.486]    [Pg.41]    [Pg.742]    [Pg.320]    [Pg.320]    [Pg.513]    [Pg.337]    [Pg.916]    [Pg.275]    [Pg.486]    [Pg.41]    [Pg.437]    [Pg.328]    [Pg.1]    [Pg.7]    [Pg.362]    [Pg.328]    [Pg.167]    [Pg.256]    [Pg.697]    [Pg.348]    [Pg.248]    [Pg.70]    [Pg.540]    [Pg.1232]    [Pg.62]    [Pg.38]   


SEARCH



Electron mixed

MIEC

Mixed Ionic

Mixed Ionic/electron

Mixed ionic and electronic conductivity MIEC) membranes

Mixed ionic electronic conductive material MIEC)

Mixed ionic electronic conductivity (MIEC

Mixed ionic-electronic conductive MIEC)

Mixed ionic-electronic conductor MIEC)

Mixed ionic-electronic conductors MIECs)

© 2024 chempedia.info