Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mdssbauer spectrometer

The Mdssbauer spectrometer was equipped with a 10 mC 5 Co/Rh source maintained at room temperature, A Northern NS-yOO multichannel analyser was used for taking the spectra. The Mdssbauer parameters were determined by least square computer programme. Tht isomer shift (5) was calculated with reference to a-Fe. The diaracieristics of iron in various iron molybdates and iron antimonate arc given in table I. [Pg.417]

Figure 10.23 shows a schematic of a Mdssbauer spectrometer. The radioactive Co source is embedded in a nonmagnetic matrix, which is chosen so as not to affect the sample or to absorb the y-rays too strongly. The system can be calibrated using Fe metal the six peaks seen in Figure 10.24 correspond to the six transitions expected for Fe. The Co source has an emission peak at 14.4 keV ... [Pg.166]

Mdssbauer spectrometers for standard applications have changed little over the past decade in their basic design. More information can, for example, be found in Shenoy et al. (1978). Multi-channel analyzers for histogram storage are now replaced by special memories or by a personal computer. [Pg.570]

In addition to being a most powerful probe of the structure and nature of solid tin containing materials in the laboratory, the Mdssbauer effect is rapidly gaining usage in the held of analysis of mineralogical tin-containing samples. A portable Mdssbauer spectrometer weighing less than 7 lb is now available for this purpose. [Pg.48]

High-surface-area mesoporous CuO- Fc203 catalysts with various CuO content (denoted as FeCuX, X=10, 15, 20, 33, 50 mol.%,) were prepared by a surfactant-assisted method of nanocrystalline particle assembly. The method is described in details in Ref [4]. All samples were characterized by XRD, N2 adsorption, TEM, H2-TPR and Mdssbauer spectroscopy. Mossbauer spectra (MS) were obtained with a Wissel electromechanical Mdssbauer spectrometer (Wissenschaftliche Elektronik GmbH, Germany) working at a... [Pg.547]

Mgssbauer Spectroscopy. All details of the Mdssbauer spectroscopy studies are described elsewhere (25,27). This includes descriptions of the spectrometer, situ cells, and the computer program used to analyze the MCssbauer spectra. [Pg.523]

Fig. 2.44. Mossbauer spectroscopy (a) nuclear transitions giving rise to the Mossbauer effect in Fe (b) principles involved in the Mossbauer spectrometer (c) Mdssbauer resonant absorption of iron in different crystal environments and the resulting spectral types. (After Vaughan and Craig, 1978 reproduced with the publisher s permission). Fig. 2.44. Mossbauer spectroscopy (a) nuclear transitions giving rise to the Mossbauer effect in Fe (b) principles involved in the Mossbauer spectrometer (c) Mdssbauer resonant absorption of iron in different crystal environments and the resulting spectral types. (After Vaughan and Craig, 1978 reproduced with the publisher s permission).
The Mdssbauer emission measurements were performed using the constant-acceleration spectrometer and w situ cell system described in (11). [Pg.237]

Optical methods of spectrometer calibration include laser interferometric methods and Moire fringe counting techniques. Since such methods depend on the accurately known wavelength of light (for example, 6328.1983 A for a He-Ne laser at 293 K under standard conditions), they are independent of any assumptions made in the iron foil technique and, thus, are intrinsically more reliable. Moreover, such methods do not require the acquisition of57 Co Mdssbauer sources and reference materials for iron absorber studies and may thus be attractive... [Pg.520]

The majority of Mdssbauer experiments that are conceived to elucidate problems of chemical structure make use of velocity modulated spectrometers. Most frequently, these are of the constant acceleration type, in which equal time intervals are spent in equal velocity increments. The primary information storage device for such spectrometers is commonly a multichannel analyzer operated in the multiscaler mode. Since the minimum observable line widths (2rnat= hf ) for S7Fe and 1,9 Sn are 0.1946 and 0.6193 mm/s, respectively, and since on the order of at least 5-10 data points on each side of the resonance maximum are... [Pg.522]

Mineeva RM (1978) Relationship between Mdssbauer spectra and defect structure in biotites from electric field gradient calculations. Phys Chem Minerals 2 267-277 Mizutani T, Fukushima Y, Kobayashi T (1991) Synthesis of 1 1 and 2 1 iron phyllosihcates and characterization of their iron state by Mdssbauer spectroscopy. Clays Clay Minerals 39 381-386 Moon N, Coffin CT, Steinke DC, Sands RH, Dnnham WR (1996) A high-sensitivity Mdssbaner spectrometer facilitates the study of iron proteins at natural abundance. Nncl Instr Meth Phys Res B 119 555-564... [Pg.346]

Ex situ Mdssbauer spectra were recorded at 293, 77, and 4.2K with a constant acceleration spectrometer using a Co in Rh source. The source was kept at room temperature. The Mossbauer parameters were resolved by fitting the collected spectra with Lorentzian shaped profiles. Isomer shifts are given relative to sodium nitroprusside at room temperature. Hyperfine fields (Heff) were calibrated against the 515 kOe field of a-Fc203 at 300K. The accuracies of the parameters are Isomer shift (IS) 0.02 mm s", quadrupole splitting (QS) 0.04 mm s, and the spectral contribution 5%. [Pg.581]

In order to visualize the experimental and theoretical requirements in DCEMS analysis. Fig. 11 shows the mesh plot of a function of two variables, i.e., the resonant count rate as a function of both Mdssbauer velocity and electron energy. The mesh surface shows the linear interpolation of a set of Moss-bauer spectra that were recorded at 17 different electron energies with the UHV Orange spectrometer set to an energy resolution of 2%. The constant... [Pg.366]

The Mdssbauer spectra were obtained in a conventional Austin spectrometer with constant acceleration at room temperature. The source was 2.13 mCi Co in a Pd matrix. The reported isomer shift values are related to natural iron ( Fe°). The data were adjusted with an iterative least-squares program which uses a Marquandt algorithm developed in the MOssbauer Spectroscopy Laboratory of the Physics Department of the University of Santiago. [Pg.280]


See other pages where Mdssbauer spectrometer is mentioned: [Pg.575]    [Pg.528]    [Pg.76]    [Pg.82]    [Pg.575]    [Pg.528]    [Pg.76]    [Pg.82]    [Pg.170]    [Pg.122]    [Pg.520]    [Pg.522]    [Pg.418]    [Pg.1432]    [Pg.364]    [Pg.820]   