Cell type Model solvent Validity index (Sk) Mass selectivity index (r ,)... [Pg.12]

Other types of detection include refractive index, fluorescence, or mass selective detectors. The use of other types of detectors, such as those based on fluorescence, may be used for assaying compounds that can be specifically detected at low concentrations in the present of nonfluorescent species. However, as few compounds are naturally fluorescent, they require chemical modification, assuming they have a suitable reactive group, to give a fluorescent derivative. [Pg.231]

Inspection of Table 1 shows that for many such membranes it is possible to find a solvent with a validity index close to unity. With such solvent, the mass selectivity parameter is generally a fairly large number, above three, suggesting that cell membranes in general discriminate sharply between solutes on the basis of their size and may well possess a fairly structured permeability barrier that behaves more like a soft polymer than like a simple fluid. [Pg.13]

The mass of the beam, for given stiffness F/8, is minimised by selecting a material with the minimum value of the material index... [Pg.71]

Figure 9.2 displays a division of the mass range into 13 intervals. After multiplication of all the individual normalized correlation values, the composite correlation index is smaller and the method achieves more selectivity than it would if a single correlation function were calculated over the full mass range. A lower limit of 0.0001 was placed on the value for each normalized interval comparison to prevent the method from generating absurdly low values. These... [Pg.186]

FIGURE 59-1. Pharmacotherapy treatment algorithm. A select population of individuals, based on body mass index (BMI) and waist circumference (WC) together with concurrent risk factors, may benefit from medication therapy as an adjunct to a program of weight loss that includes diet, exercise, and behavioral modification. (CHD, coronary heart disease DM, diabetes mellitus, HTN, hypertension INC WC, >40 inches for males and >35 inches for females LCD, low-calorie diet.)... [Pg.679]

Manufacturers publish their product s performance characteristics as specifications, which are often used by the customer for comparison during the selection process. Table 1 shows the specifications of an Agilent 1100 Series Quaternary Pump, which is quite representative of other high-end analytical pumps. Note pulsation is particularly detrimental to the performance of flow-sensitive detectors (e.g., mass spectrometer, refractive index detector). Differences in dwell volumes and composition accuracy between HPLC systems might cause problems during method transfers. [Pg.56]

The emission index in general is defined as the mass of pollutant emitted per unit mass of fuel consumed. In quasi-steady diffusion flames, this is the ratio of the mass flux of pollutant out of the flame to the mass rate of consumption of fuel per unit flame area. Depending on the application, it may be more desirable to consider only the flux of pollutant to the air or the sum of the pollutant flux to both air and fuel. The latter definition is selected here, and a pollutant balance for the flame then enables the emission index to be expressed as the ratio of the mass rate of production of pollutant per unit area to the mass rate of consumption of fuel per unit area. In terms of the mass rate of production of species i per unit volume cDj, the mixture fraction, and the magnitude of its gradient VZ, the mass rate of production of species i per unit area is... [Pg.410]

As a result of advances in detection technology, newer HPLC detection techniques may be utilized. For example, evaporative light-scattering detection and refractive index detection may be used to quantify impurities with poor or no UV chromophore. Conductivity detection may also be used. In some cases, when no chromophore is present, chemical derivatization may be used to add a chromophore. Increasingly, tandem techniques such as liquid chromatography mass spectrometry (LC-MS) and GC-MS are utilized for impurity characterization. The highly selective nature of LC-MS ensures that few impurities are undetected. [Pg.12]

The effects of non-uniform distribution of the catalytic material within the support in the performance of catalyst pellets started receiving attention in the late 60 s (cf 1-4). These, as well as later studies, both theoretical and experimental, demonstrated that non-uniformly distributed catalysts can offer superior conversion, selectivity, durability, and thermal sensitivity characteristics over those wherein the activity is uniform. Work in this area has been reviewed by Gavriilidis et al. (5). Recently, Wu et al. (6) showed that for any catalyst performance index (i.e. conversion, selectivity or yield) and for the most general case of an arbitrary number of reactions, following arbitrary kinetics, occurring in a non-isothermal pellet, with finite external mass and heat transfer resistances, the optimal catalyst distribution remains a Dirac-delta function. [Pg.410]


See other pages where Mass selectivity index is mentioned: [Pg.18]    [Pg.23]    [Pg.18]    [Pg.23]    [Pg.45]    [Pg.129]    [Pg.458]    [Pg.71]    [Pg.136]    [Pg.185]    [Pg.195]    [Pg.71]    [Pg.110]    [Pg.236]    [Pg.282]    [Pg.707]    [Pg.169]    [Pg.62]    [Pg.537]    [Pg.317]    [Pg.393]    [Pg.88]    [Pg.159]    [Pg.505]    [Pg.50]    [Pg.488]    [Pg.44]    [Pg.166]    [Pg.686]    [Pg.210]    [Pg.171]    [Pg.435]    [Pg.320]    [Pg.537]    [Pg.169]    [Pg.267]    [Pg.150]    [Pg.28]    [Pg.37]    [Pg.40]   