Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mass advantages

As previously mentioned, the nickel—titanium alloys have been the most widely used shape memory alloys. This family of nickel—titanium alloys is known as Nitinol (Nickel Titanium Naval Ordnance Laboratory in honor of the place where this material behavior was first observed). Nitinol have been used for military, medical, safety, and robotics applications. Specific usages include hydraulic lines capable of F-14 fighter planes, medical tweezers, anchors for attaching tendons to bones, eyeglass frames, underwire brassieres, and antiscalding valves used in water faucets and shower heads (38,39). Nitinol can be used in robotics actuators and micromanipulators that simulate human muscle motion. The ability of Nitinol to exert a smooth, controlled force when activated is a mass advantage of this material family (5). [Pg.252]

The great advantage of the RDE over other teclmiques, such as cyclic voltannnetry or potential-step, is the possibility of varying the rate of mass transport to the electrode surface over a large range and in a controlled way, without the need for rapid changes in electrode potential, which lead to double-layer charging current contributions. [Pg.1936]

Amongst the greatest advantages of channel-flow electrodes is the possibility of controlling the rate of mass... [Pg.1938]

In a 250 ml. conical flask mix a solution of 14 g. of sodium hydroxide in 40 ml. of water and 21 g. (20 ml.) of pure benzaldehyde (Section IV,115). Add 15 g. of hydroxylamine hydrochloride in small portions, and shake the mixture continually (mechanical stirring may be employed with advantage). Some heat is developed and the benzaldehyde eventually disappears. Upon coohiig, a crystalline mass of the sodium derivative separates out. Add sufficient water to form a clear solution, and pass carbon dioxide into the solution until saturated. A colourless emulsion of the a or syn-aldoxime separates. Extract the oxime with ether, dry the extract over anhydrous magnesium or sodium sulphate, and remove the ether on a water bath. Distil the residue under diminished pressure (Fig. 11,20, 1). Collect the pure syn-benzaldoxime (a-benzald-oxime) at 122-124°/12 mm. this gradually solidifies on cooling in ice and melts at 35°. The yield is 12 g. [Pg.719]

Sometimes the strongly basic properties of Gngnard reagents can be turned to synthetic advantage A chemist needed samples of butane specifically labeled with deuterium the mass 2 isotope of hydrogen as shown... [Pg.621]

When the analytical method s selectivity is insufficient, it may be necessary to separate the analyte from potential interferents. Such separations can take advantage of physical properties, such as size, mass or density, or chemical properties. Important examples of chemical separations include masking, distillation, and extractions. [Pg.224]

A TOF analyzer can be used alone or in conjunction with other analyzers to function as a hybrid mass spectrometer. The hybrids provide advantages not attainable, or difficult to attain by the... [Pg.154]

The AutoSpec -TOF hybrid mass spectrometer combines the advantages of a magnetic/electric-sector instrument with those of time-of-flight to give a versatile instrument capable of MS or MS/MS at high or low resolution. [Pg.161]

Ions formed in an electrospray or similar ion source are said to be thermolized, which is to say that their distribution of internal energies is close to that expected for their normal room-temperature ground state. Such ions have little or no excess of internal energy and exhibit no tendency to fragment. This characteristic is an enormous advantage for obtaining molecular mass information from the stable molecular ions, although there is a lack of structural information. [Pg.167]

Other instrumental advantages include its high sensitivity and a linear mass scale to m/z 10,000 at full sensitivity. The linearity of the mass scale means that it is necessary to calibrate the spectrometer using a single or sometimes two known mass standards. Some calibration is necessary because the start of the mass scale is subject to some instrumental zero offset. The digitized accumulation of spectra provides a better signal-to-noise ratio than can be obtained from one spectrum alone. [Pg.167]

The term Q/TOF is used to describe a type of hybrid mass spectrometer system in which a quadrupole analyzer (Q) is used in conjunction with a time-of-flight analyzer (TOP). The use of two analyzers together (hybridized) provides distinct advantages that cannot be achieved by either analyzer individually. In the Q/TOF, the quadrupole is used in one of two modes to select the ions to be examined, and the TOF analyzer measures the actual mass spectrum. Hexapole assemblies are also used to help collimate the ion beams. The hybrid orthogonal Q/TOF instrument is illustrated in Figure 23.1. [Pg.169]

Note that in mass spectrometry/mass spectrometry (MS/MS) applications, quadrupole and magnetic sectors can be used together advantageously. It is also worth noting that the quadrapole can be operated without the DC voltages. In this RF-only mode, no mass separation occurs, and these quadrapoles are used as ion transmission guides, described in Chapter 49. [Pg.186]

A major advantage of the TOF mass spectrometer is its fast response time and its applicability to ionization methods that produce ions in pulses. As discussed earlier, because all ions follow the same path, all ions need to leave the ion source at the same time if there is to be no overlap between m/z values at the detector. In turn, if ions are produced continuously as in a typical electron ionization source, then samples of these ions must be utihzed in pulses by switching the ion extraction field on and off very quickly (Figure 26.4). [Pg.192]


See other pages where Mass advantages is mentioned: [Pg.252]    [Pg.511]    [Pg.178]    [Pg.63]    [Pg.268]    [Pg.2840]    [Pg.38]    [Pg.394]    [Pg.505]    [Pg.252]    [Pg.511]    [Pg.178]    [Pg.63]    [Pg.268]    [Pg.2840]    [Pg.38]    [Pg.394]    [Pg.505]    [Pg.693]    [Pg.812]    [Pg.1312]    [Pg.1330]    [Pg.1331]    [Pg.1355]    [Pg.1939]    [Pg.2070]    [Pg.2353]    [Pg.2702]    [Pg.229]    [Pg.204]    [Pg.418]    [Pg.601]    [Pg.233]    [Pg.585]    [Pg.2]    [Pg.27]    [Pg.55]    [Pg.161]    [Pg.165]    [Pg.171]    [Pg.173]    [Pg.173]    [Pg.185]    [Pg.185]    [Pg.186]    [Pg.192]   
See also in sourсe #XX -- [ Pg.2 , Pg.21 , Pg.29 , Pg.34 ]

See also in sourсe #XX -- [ Pg.2 , Pg.21 , Pg.29 , Pg.34 ]




SEARCH



Advantages of Mass Spectrometry

Fast atom bombardment mass advantages

Hybrid mass spectrometer advantages

Imaging mass spectrometry advantage

Isotope ratio mass spectrometry advantages

Liquid chromatography-mass advantages

Liquid chromatography/mass spectrometry advantages

Mass flow advantages

Mass screening advantages

Mass spectrometer advantages

Mass spectrometer major advantage

Mass spectrometry advantages

Spark-source mass spectrometer advantages

Specific advantages of mass spectrometry in peptide sequencing

Tandem mass spectrometry advantages

© 2024 chempedia.info