Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Lubricated, running

Lubricants used in PVC formulations are briefly described. The results of trials carried out on calcium/ zinc stabilised PVC formulations with and without lubricants run on laboratory and production twin-screw extruders aimed at optimising the formulations are also presented and discussed. [Pg.76]

The storage of chemicals, lubricants, aviation fuel and diesel fuel is normally on the platforms, with chemicals kept in bulk storage or in drums depending on the quantities. A typical diesel storage would be adequate to run back-up power generators for around a week, but the appropriate storage for each item would need to be specified in the FDR... [Pg.285]

Hot running Preventive maintenance bearings., Monitor bearings temperature Purging and sealing to keep solvents out, if solvent (even vapor) exposure is possible Use improved bearing lubricant CCPS G-29... [Pg.68]

An interlock is provided through a centrifugal type of pressure switch (PS) to trip the engine in the case of low lube (lubricating) oil pressure during a run. Since during a. start oil pre.s.sure has not built up, a timer, 7 j is introduced to bypass the trip interlock and avoid a false trip. A relay (contactor), d], is used to provide lube oil pressure interlock. [Pg.507]

The seal must also resist the vibrations from the explosions of internal combustion in the engine, chassis and wheel vibrations, and even potholes in the road. This seal must resist strong chemicals (anti freeze, anti-rust agents, radiator stop-leak and sealant chemicals, gasoline and lubricant residuals), and also solid particles (rust, iron slag, minerals, asbestos fibers, and silica from the engine casting mold). In spite of all this, the mechanical seal on the water pump of your car can run 7, 10, even 15 years without problems. [Pg.181]

Dry Running Pump Again, no lubrication or dissipation of hear. Remove the heat with a double seal and barrier tank with forced convective flow. [Pg.220]

For gas turbines, especially the more advanced high-temperature gas turbines, the oil of choice should be synthetic oil, since synthetic oils have a high flash point. Gas turbine lubrication systems should be run for about 20 minutes after shutdown since maximum temperatures are reached after 10 minutes of shutdown especially in the bearing area. Most gas turbines are also on turning gear to avoid sagging in the shaft. Mineral oils can be used for the compressor. It is not uncommon to have two types of oil in a petrochemical plant. Mineral oil costs much less than the synthetic oil. [Pg.549]

Lubricating and seal oil systems cleaned Instrumentation and controls checked Preliminary operation of lubricating and seal oil systems Operation with air Vacuum Equipment Alignment run-in testing Pumps... [Pg.331]

Mechanical testing of the non-lubricated helical-lobe compressors is modified from the previously described lest. For example, API 619 only requires a two-hour mechanical run. The procedures and monitoring requirements are generally the same as previously described. A run comparable to the overspeed run is the heat run. The compressor is run on air at the maximum allowable speed, and the discharge temperature is allowed to stabilize at a value 20°F higher than the rated discharge temperature. The compressor is then run for 30 minutes. [Pg.413]

Several steps can be taken to maximize the run time for the reciprocating compressor. Since wear is a function of rubbing speed, the piston speed can be kept to a minimum. Chapter 3 made recommendations for piston speed. Reliability problems due to valves are reputed to account tor 40% of the maintenance cost of the compressor. Valves are the single largest cause for unplanned shutdowns. Basically, valve life can he increased by keeping the speed of the compressor as low as practical. At 360 rpm, the valves are operated six times a second. At 1,200 rpm, ihc valves operate 20 times a second or 1,728,000 times in a day. It is not difficult to understand why the valves are considered critical. To keep the reliability in mind, valve type, material selection and application considerations such as volume ratio, gas corrosiveness, and gas cleanliness need attention by the experts. One final note is that while lubrication is an asset to the rubbing parts, it is not necessarily good for valve reliability. [Pg.475]

From the third reactor the polymer is then run into a devolatilising ( stripping ) vessel in the form of thin strands. At a temperature of 225°C the solvent, residual monomer and some very low molecular weight polymers are removed, condensed and recycled. The polymer is then fed to extruder units, extruded as filaments, granulated, lubricated and stored to await dispatch. [Pg.431]

The compressor manufacturer must be consulted if the cylinder is to be run single acting with the frame end unloaded. Many times rod load reversal and proper lubrication may not be achieved while running single acting with the frame end unloaded. [Pg.304]


See other pages where Lubricated, running is mentioned: [Pg.357]    [Pg.113]    [Pg.191]    [Pg.724]    [Pg.187]    [Pg.725]    [Pg.442]    [Pg.357]    [Pg.113]    [Pg.191]    [Pg.724]    [Pg.187]    [Pg.725]    [Pg.442]    [Pg.66]    [Pg.150]    [Pg.551]    [Pg.897]    [Pg.403]    [Pg.907]    [Pg.1853]    [Pg.2521]    [Pg.2537]    [Pg.65]    [Pg.244]    [Pg.246]    [Pg.251]    [Pg.166]    [Pg.203]    [Pg.233]    [Pg.62]    [Pg.533]    [Pg.775]    [Pg.96]    [Pg.337]    [Pg.377]    [Pg.462]    [Pg.487]    [Pg.551]    [Pg.503]    [Pg.658]    [Pg.84]    [Pg.205]    [Pg.471]    [Pg.73]   
See also in sourсe #XX -- [ Pg.427 ]




SEARCH



Running

© 2024 chempedia.info