Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Loops acquiring

There are two important steps that we must follow. First, make sure you go through the MATLAB tutorial (Session 6) carefully to acquire a feel on the probable shapes of root locus plots. Secondly, test guidelines 3 and 4 listed above for every plot that you make in the tutorial. These guidelines can become your most handy tool to deduce, without doing any algebra, whether a system will exhibit underdamped behavior. Or in other words, whether a system will have complex closed-loop poles. [Pg.138]

Of course, these steps usually are not processed in a linear order. Rather there are loops and iterations. The acquired data might lead to new insights in the problem... [Pg.23]

The U-tube is permanently or semipermanently deployed in a wellbore to provide the ability to periodically (or continuously) acquire samples. The U-tube is extremely simple, consisting of a loop of tubing, which has a tee at its base, terminating at a check valve that permits fluid to enter the loop of tubing (Fig. 1). A filter at the inlet removes particulates that can interfere with the operation of the check valve. At the surface, the U-tube drive leg is connected to a supply of high pressure N2 that closes the check valve... [Pg.281]

Matlab supplies the function Isqnonneg that performs a non-negative least-squares fit of the kind y=Ca+r, where y and a are column vectors. The function computes the best vector a with only positive entries. This equation corresponds to data acquired at only one wavelength. In our application, the columns of A have to be computed individually in a loop over all wavelengths, in each instance using the appropriate column of Y. C is the complete matrix of concentrations. It is, of course, the same for all wavelengths. [Pg.284]

Figure 6J8 (a) The chromatogram from a 0.75 mg injection of an impure steroidal drug substance. Peaks 1-5 are at levels of 2-3% each. The individual peaks were stored in BPSU loops, (b) NMR spectra were acquired with NOESY presaturation with an acquisition time of 10 h on a Bruker DRX500 fitted with a 4-mm SEl z-gradient EC probe with a 120 pi active cell volume. [Pg.201]

It is common for liquid nitrogen frozen protein crystals to acquire a patina of ice on the surface of the cryoprotectant. Diffraction of X-rays from even small ice crystals can mask reflections from the protein crystal. In addition, the presence of excessive amounts of ice can obscure the true position of the nylon loop, thereby resulting in the failure to place the crystal in the X-ray beam. It is, therefore, essential to remove ice crystals prior to diffraction analysis. [Pg.179]

Most often, the electrochemical impedance spectroscopy (EIS) measurements are undertaken with a potentiostat, which maintains the electrode at a precisely constant bias potential. A sinusoidal perturbation of 10 mV in a frequency range from 10 to 10 Hz is superimposed on the electrode, and the response is acquired by an impedance analyzer. In the case of semiconductor/electrolyte interfaces, the equivalent circuit fitting the experimental data is modeled as one and sometimes two loops involving a capacitance imaginary term in parallel with a purely ohmic resistance R. [Pg.312]

Several studies have suggested that patients with IM resistance secondary to mutations in the P-loop have a poorer prognosis than patients with mutations in other portions of the ABLl kinase domain. A study from Australia detected mutations in 27 of 144 patients at 17 different residues. Twenty-four of these 27 patients (89%) developed acquired resistance. Thirteen of these 24 had mutations in the P-loop, and 12 of these patients died with a median survival of only 4.5 months after mutation detection. [Pg.139]

Finally, use of the loop-storage/loop-transfer technique provides an escape from this dilemma. The chromatogram is acquired without any interruption, the mass spectrometer acquires MS and MS2 spectra online, and provides spectroscopic information which allows reliable peak selection for the storage procedure. The MS unit is used above all as a very selective and sensitive detector. After the chromatographic separation, it is available for other purposes and the collected samples are then independently analysed in the NMR spectrometer. [Pg.32]

The H LC-NMR spectra were obtained on peaks stored in the BPSU-36 storage loops. Data were acquired with WET [41] solvent suppression on the residual water and acetonitrile signals. A composite 90° observe pulse, (tt/2)y—(tt/2) x—(tt/2) y—(tt/2)x, was employed. Spectra were collected into 32K data points over a width of 12 019 Hz, giving an acquisition time of 1.36 s, with an additional relaxation delay of 1.5 s. The data were multiplied by a line-broadening function of 1 Hz to improve the signal-to-noise ratio and zero-filled by a factor of two before Fourier transformation. [Pg.100]

Osmotrophs are organotrophic organisms that acquire nutrients from their environment one molecule at a time. Osmotrophs include most members of the bacteria and archaea domains, as well as fungi and several protistan groups. Except in association with coarse organic particles where eukaryotic fungi and oomycetes are prominent, prokaryotes dominate heterotrophic metabolism, so are the focus of the text that follows. We use the term bacteria loosely, recognizing that heterotrophic archaea may well be major consitituents of the microbial loop of many systems. [Pg.482]

While an intensity profile at the detector as a function of retardation may be acquired in a step-scan mode, two major drawbacks affect this method of interferogram acquisition. First, the mirror(s) requires stabilization times with mirror inertia and time constants of the control loop determining this parameter in achieving a given optical retardation. Second, additional hardware and control mechanisms need to be incorporated into the spectrometer, thus increasing instrument cost and complexity. In certain cases, however, the utility of a step-scan instrument justifies this additional expense. Historically, the step-scan approach was favored with slow detectors. With the advent of fast detectors and electronics, step-scan interferometry became... [Pg.6]


See other pages where Loops acquiring is mentioned: [Pg.115]    [Pg.115]    [Pg.10]    [Pg.477]    [Pg.89]    [Pg.300]    [Pg.135]    [Pg.542]    [Pg.162]    [Pg.194]    [Pg.55]    [Pg.53]    [Pg.54]    [Pg.192]    [Pg.84]    [Pg.114]    [Pg.154]    [Pg.282]    [Pg.460]    [Pg.32]    [Pg.435]    [Pg.388]    [Pg.394]    [Pg.406]    [Pg.192]    [Pg.186]    [Pg.121]    [Pg.291]    [Pg.200]    [Pg.540]    [Pg.85]    [Pg.1187]    [Pg.249]    [Pg.373]    [Pg.285]    [Pg.160]    [Pg.29]    [Pg.137]    [Pg.23]   


SEARCH



Acquired

© 2024 chempedia.info