Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Long glasses

A very suitable apparatus for semi-micro steam-distillation, particularly for suspensions that are likely to bump badly, is showm in Fig. 44. This consists of a 50 ml. Kjeldahl flask, clamped at an angle of 45°, and fitted with a long glass tube for the inlet of steam. The Outlet-tube is bent twice, first at 135° and then at 45° as shown, and fitted into a small water-condenser. [Pg.66]

Samples and calibration standards are prepared for analysis using a 10-mL syringe. Add 10.00 mL of each sample and standard to separate 14-mL screw-cap vials containing 2.00 mL of pentane. Shake vigorously for 1 min to effect the separation. Wait 60 s for the phases to separate. Inject 3.0-pL aliquots of the pentane layer into a GC equipped with a 2-mm internal diameter, 2-m long glass column packed with a stationary phase of 10% squalane on a packing material of 80/100 mesh Chromosorb WAW. Operate the column at 67 °C and a flow rate of 25 mL/min. [Pg.576]

In an 800-ml. stainless-steel flanged beaker are placed 240 g. of potassium hydroxide pellets and 50 ml. of water. When the mush has cooled, 40.0 g. (0.263 mole) of 2-hydroxy-3-methyl-benzoic acid (Note 1) is added, and the slurry is stirred with a long glass rod. The beaker is placed firmly in a clamp (Note 2) and set in a cold oil bath (Note 3) in a hood, and 240 g. (1.00 mole) of lead dioxide is stirred in all at once (Note 4). The oil... [Pg.48]

Exhibition of 1851 marked one of the positive turning points, with a separate boiler plant providing steam to power exhibits in the enormous Crystal Palace, a 600-meter-long glass structure. A similar exliibition, complete with separate boiler house, was held in New York two years later. [Pg.343]

Researchers at Satidia National Labs use a trough of parabolic mirrors to focus sunlight on a long glass tube in order to detojdfy water. (U.S. Department of Energy)... [Pg.1061]

Fig. 8-58 Long glass fiber RP molding compounds have higher and more metal-like than conventional shorter fiber compounds. Fig. 8-58 Long glass fiber RP molding compounds have higher and more metal-like than conventional shorter fiber compounds.
The pressure of the atmosphere can be measured with a barometer, an instrument invented in the seventeenth century by Evangelista Torricelli, a student of Galileo. Torricelli (whose name coincidentally means little tower in Italian) formed a little tower of liquid mercury. He sealed a long glass tube at one end, filled it with mercury, and inverted it into a beaker (Fig. 4.4). The column of mercury fell until the pressure that it exerted at its base matched the pressure exerted by the atmosphere. To interpret measurements with a barometer, we need to find how the height of the column of mercury depends on the atmospheric pressure. [Pg.263]

Further data provided by Honeywell relating the polyamide-6 polymers confirm these trends in property [28]. In addition, further benefits of short/long glass fiber incorporation, together with nanoclay incorporation, are clearly revealed. [Pg.34]

The air around us is a huge reservoir of gas that exerts pressure on the Earth s surface. This pressure of the atmosphere can be measured with an instmment called a barometer. Figure 5 shows a schematic view of a simple mercury barometer. A long glass tube, closed at one end, is filled with liquid mercury. The filled tube is inverted carefully into a dish that is partially filled with more mercuiy. The force of gravity pulls downward on the mercury in the tube. With no opposing force, the mercury would all ran out of the tube and mix with the mercury in the dish. [Pg.282]

LGFPP Long glass-fibre reinforced tetrafluoroethylene Perfluoroalkoxy... [Pg.762]

Fig. 5.6. Multiple filamentation in a 5 cm long glass cell containing coumarin dye in ethanol. Control over filamentation was obtained by means of a wire mesh (see text)... Fig. 5.6. Multiple filamentation in a 5 cm long glass cell containing coumarin dye in ethanol. Control over filamentation was obtained by means of a wire mesh (see text)...
One advance in the area of LLE is the use of solid supports that facilitate the partitioning of the analyte(s) of interest. LLE extraction methods involving nonpolar matrices often suffer from the formation of emulsions, and using the solid support is a possible solution. In one study, polychlorinated biphenyls, dioxins, and furans were extracted from the lipid fraction of human blood plasma [32], using diatomaceous earth as the solid support. Long glass columns (30 cm) were packed with several layers of Chem-Elut (a Varian product) and sodium chloride. The plasma samples were diluted with water and ethanol and passed over the columns. A mixture of isopropanol and hexane (2 3) was passed over the column and the LLE was performed. It can be concluded that the LLE with the solid support is easier to perform and can be applied to other lipid heavy matrices such as milk [32]. [Pg.40]

We have already met the concept of error propagation a few times when dealing with the change of variable formulas for probability distribution, but let us try to illustrate it with a simple example. We want to measure the diffusion coefficient Q) of uranium in a glass by maintaining at a specific temperature and for a specific time t the surface of one long glass rod in contact with a concentrated solution of uranium. We admit without further justification (see Section 8.5) that the depth x of uranium... [Pg.217]

Experiment 2.—One c.c. of freshly prepared acetaldehyde is shaken for a few minutes in a long glass cylinder provided with a tightly fitting rubber stopper. Half of the liquid is then poured into a little dilute potassium iodide solution and half into two or three volumes of water which is then tested with litmus paper to show the presence of the acetic acid formed. It will be found that the aldehyde which has been dissolved in water hardly liberates any iodine from potassium iodide solution after standing for some time. [Pg.213]

Bush, S. F., Impact Strengths of injection molded long glass fiber composites. Plast. Rubber Composites Proc. Appl., 24, 139 (1995). [Pg.560]

ArF aramid fibre CF carbon fibre GF glass fibre LGF long glass fibre UD nnidirectional... [Pg.5]

Framework pultruded long glass fibre reinforced plastics. [Pg.77]

Frames and seat slides of front and back seats can be made out of GMTs. Long glass fibre reinforced polyamides are used for very light seats intended for sports cars. [Pg.100]

Figure 4.8 ((a), (b), (c), and (d)) displays, in a simplified manner, the alteration of the basic properties of homopolymer (H-PP) when modified with other comonomers (co-PP), with elastomer (impact) or with an inorganic filler mineral, talc, short or long glass fibres (SGF or LGF). [Pg.241]

Currently, one of the most important applications is the front-end of recent cars such as the Mini Cooper from BMW, Mazda 6, Audi A6, Ford Focus and VW Polo, associating long glass fibre reinforced polypropylene injected onto stamped metal, which leads to weight savings in the range of 30-35% compared to traditional solutions. [Pg.752]

Table 6.35 displays some basic property examples of long glass fibre reinforced polyamides and polypropylenes. [Pg.823]


See other pages where Long glasses is mentioned: [Pg.145]    [Pg.480]    [Pg.930]    [Pg.297]    [Pg.6]    [Pg.371]    [Pg.297]    [Pg.450]    [Pg.499]    [Pg.30]    [Pg.410]    [Pg.88]    [Pg.442]    [Pg.116]    [Pg.104]    [Pg.387]    [Pg.145]    [Pg.480]    [Pg.930]    [Pg.1159]    [Pg.571]    [Pg.712]    [Pg.449]    [Pg.470]    [Pg.267]    [Pg.121]    [Pg.40]    [Pg.5]    [Pg.7]    [Pg.246]   
See also in sourсe #XX -- [ Pg.524 , Pg.566 ]

See also in sourсe #XX -- [ Pg.524 , Pg.566 ]