Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Loading of supports

Loading of supports can be done in two ways batch loading and column loading. [Pg.104]

The radioautographic work suggests another model illustrated in Fig. XII-11. The load is supported over area A, with metal contacts of shear strength s over a portion of the area ctA and film-film contacts of shear strength Sf over the rest of the area. In analogy to Eq. XII-9, one can write the total frictional force, F as... [Pg.448]

Products. Vibration isolators typically are selected to have a static deflection, under load, that yields a natural frequency no more than one-third the lowest driving frequency that must be isolated (see Eig. 7). The supporting stmcture must have sufficient stiffness so it does not deflect under the load of the supported equipment by more than one-tenth the deflection of the isolator itself (6). In addition to static deflection requirements, vibration isolators are selected for a particular appHcation according to their abiHty to carry an imposed load, and to withstand the environment in which they are used (extreme temperatures, chemical exposure, etc). [Pg.319]

Each precious metal or base metal oxide has unique characteristics, and the correct metal or combination of metals must be selected for each exhaust control appHcation. The metal loading of the supported metal oxide catalysts is typically much greater than for nobel metals, because of the lower inherent activity pet exposed atom of catalyst. This higher overall metal loading, however, can make the system more tolerant of catalyst poisons. Some compounds can quickly poison the limited sites available on the noble metal catalysts (19). [Pg.503]

Rediice nonvertical loads imposed by piping on its supports so as to minimize cost of support foundations. [Pg.1004]

Stokes Vacuum, Inc. Price includes dryer, 15-lVin jacket, drive with motor, internal filter, and trunnion supports for concrete or steel foundations. Horsepower is established on 65 percent volume loading of material with a hulk density of 50 Ih/ft. Models of 250 ft, 325 ft, and 400 ft have extended surface area. [Pg.1215]

Typical platinum catalyst loadings needed to support the anodic and cathodic reactions are currently 1 to 2 mg/cm" oi active cell area. Owing to the cost of platinum, substantial efforts have been made to reduce the catalyst loading, and some fuel cells have operated at a catalyst loading of 0.25 mg/cm". [Pg.2412]

The fault ctirrents also develop electrodynamic foi ces, Fii, as in equation (28.4) due to the sub-transient d.c. component. These forces play an important role in the meehanical design of the interrupting device, the load-bearing and mounting structuies for the interrupter and the bus system, and the hardware used in a switchgear assembly. All such mechanical parts, supports and hardw-are should be adequate to withstand such forces when they arise, A procedure to arrive at the ideal size of the current-carrying components, mounting structure, type of supports and hardware cte, is discussed in detail in Example 28.12. [Pg.365]

Endiiranee of supporting and nUHinting sirueture, load-bearing members and hardware... [Pg.367]

This is a very important and well tested method for the quantitative determination of loading of Fmoc protected compounds particularly that of Fmoc (fluorenylmethoxycarbonyl) amino acids on solid support. Fmoc groups can... [Pg.76]

The twisting rubber hoses or o ringed elbows which connect the rotating pan necks with pipe and the wear plate to the face of the stationary valve The condition of the high impact nozzles mounted on the cloth wash manifold and, for wet cake discharge, the sluicing manifold The support rollers which take the vertical load of the entire machine and the horizontal thrust rolls that maintain the rotating frame concentric The toothed rim and sprocket which drives the pan filter... [Pg.230]

For equilibrium of forces it can be seen that the applied load is supported jointly by the spring and the dashpot, so... [Pg.88]

A sheet of chopped strand mat-reinforced polyester is 5 mm thick and 10 mm wide. If its modulus is 8 GN/m calculate its flexural stiffness when subjected to a point load of 200 N midway along a simply supported span of 300 mm. Compare this with the stiffness of a composite beam made up of two 2.5 mm thick layers of this reinforced material separated by a 10 mm thick core of foamed plastic with a modulus of 40 MN/m. ... [Pg.244]

Deflection of a duct The largest deformation of a duct subjected to an imposed load, given as the measured difference in distance between a plane through the points of support and a plane through the lowest point of the duct under a load. [Pg.1427]


See other pages where Loading of supports is mentioned: [Pg.377]    [Pg.215]    [Pg.698]    [Pg.97]    [Pg.121]    [Pg.29]    [Pg.377]    [Pg.215]    [Pg.698]    [Pg.97]    [Pg.121]    [Pg.29]    [Pg.45]    [Pg.427]    [Pg.1048]    [Pg.938]    [Pg.1787]    [Pg.1103]    [Pg.325]    [Pg.337]    [Pg.59]    [Pg.466]    [Pg.36]    [Pg.271]    [Pg.527]    [Pg.172]    [Pg.944]    [Pg.1002]    [Pg.1002]    [Pg.1136]    [Pg.1980]    [Pg.2505]    [Pg.74]    [Pg.269]    [Pg.489]    [Pg.485]    [Pg.368]    [Pg.57]    [Pg.173]    [Pg.198]    [Pg.52]    [Pg.57]   


SEARCH



BUCKLING OF SIMPLY SUPPORTED LAMINATED PLATES UNDER IN-PLANE LOAD

DEFLECTION OF SIMPLY SUPPORTED LAMINATED PLATES UNDER DISTRIBUTED TRANSVERSE LOAD

Load support

Loading of Metals on Carbon Supports

© 2024 chempedia.info