Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Light real-time

Stegemann, D, Reimche, W. Schmidtbauer, J. Investigations of Light Metal Casting Processes by Real Time Microfocus Radioscopy. The European Journal of Nondestructive Testing, Vol. l,No. 3, S. 107117, Jan. 1992... [Pg.17]

The contractor at Site H had established area and personnel sampling consistent with HAZWOPER requirements. A photo ionization detector (PID) and a real-time aerosol monitor (RAM) were used on a daily basis to screen for potentially hazardous levels of contaminants. On a weekly basis, personal air samples were collected and submitted for laboratory analysis. PPE requirements, however, were often not based on this data because the oversight agency had established inflexible minimum PPE requirements. The audit team found many of the PPE requirements on Site H to be excessive in light of site monitoring data and hazard determinations. [Pg.190]

FIGURE 5.6 Calcitonin receptor responses, (a) Real-time melanin dispersion (reduced light transmittance) caused by agonist activation (with human calcitonin) of transfected human calcitonin receptors type II in melanophores. Responses to 0.1 nM (filled circles) and lOnM (open circles) human calcitonin, (c) Dose-response curves to calcitonin in melanophores (open circles) and HEK 293 cells, indicating calcium transient responses (filled circles). [Pg.83]

The background problem can be further overcome when using a surface-confined fluorescence excitation and detection scheme at a certain angle of incident light, total internal reflection (TIR) occurs at the interface of a dense (e.g. quartz) and less dense (e.g. water) medium. An evanescent wave is generated which penetrates into the less dense medium and decays exponentially. Optical detection of the binding event is restricted to the penetration depth of the evanescent field and thus to the surface-bound molecules. Fluorescence from unbound molecules in the bulk solution is not detected. In contrast to standard fluorescence scanners, which detect the fluorescence after hybridization, evanescent wave technology allows the measurement of real-time kinetics (www.zeptosens.com, www.affinity-sensors.com). [Pg.493]

The performance of a biotreatment system ultimately depends on optimization of the activity of microbes and the ability to control the process parameters of the treatment system [157]. In this respect, the ability to monitor gene copy numbers and gene expression is highly useful for real time optimization of the efficiency of a biotreatment system. Advanced molecular techniques as well as low cost methods (e.g., antibody detection of enzymes based on color reaction strips fluorescence i.e., GFP marked organisms with UV light detection) can also be applied to monitor the microbial community structure, persistence of the added bacteria, and their interactions with indigenous populations. [Pg.28]

The objective of the present work was to determine the influence of the light intensity on the polymerization kinetics and on the temperature profile of acrylate and vinyl ether monomers exposed to UV radiation as thin films, as well as the effect of the sample initial temperature on the polymerization rate and final degree of cure. For this purpose, a new method has been developed, based on real-time infrared (RTIR) spectroscopy 14, which permits to monitor in-situ the temperature of thin films undergoing high-speed photopolymerization, without introducing any additive in the UV-curable formulation 15. This technique proved particularly well suited to addressing the issue of thermal runaway which was recently considered to occur in laser-induced polymerization of divinyl ethers 13>16. [Pg.64]


See other pages where Light real-time is mentioned: [Pg.1721]    [Pg.1721]    [Pg.656]    [Pg.1029]    [Pg.1632]    [Pg.1667]    [Pg.160]    [Pg.162]    [Pg.21]    [Pg.201]    [Pg.129]    [Pg.397]    [Pg.457]    [Pg.187]    [Pg.66]    [Pg.719]    [Pg.467]    [Pg.258]    [Pg.50]    [Pg.82]    [Pg.83]    [Pg.88]    [Pg.182]    [Pg.266]    [Pg.172]    [Pg.111]    [Pg.366]    [Pg.265]    [Pg.14]    [Pg.236]    [Pg.104]    [Pg.293]    [Pg.345]    [Pg.94]    [Pg.156]    [Pg.295]    [Pg.255]    [Pg.221]    [Pg.108]    [Pg.174]    [Pg.51]    [Pg.158]    [Pg.258]    [Pg.568]    [Pg.63]   
See also in sourсe #XX -- [ Pg.98 ]




SEARCH



Real-time

© 2024 chempedia.info