Level measurements electrical methods

Thermal Methods Level-measuring systems may be based on the difference in thermal characteristics oetween the fluids, such as temperature or thermal conductivity. A fixed-point level sensor based on the difference in thermal conductivity between two fluids consists of an electrically heated thermistor inserted into the vessel. The temperature of the thermistor and consequently its electrical resistance increase as the thermal conductivity of the fluid in which it is immersed decreases. Since the thermal conductivity of liquids is markedly higher than that of vapors, such a device can be used as a point level detector for liquid-vapor interface. [Pg.764]

The key factor in voltammetry (and polarography) is that the applied potential is varied over the course of the measurement. The voltammogram, which is a current-applied potential curve, / = /( ), corresponds to a voltage scan over a range that induces oxidation or reduction of the analytes. This plot allows identification and measurement of the concentration of each species. Several metals can be determined. The limiting currents in the redox processes can be used for quantitative analysis this is the basis of voltammetric analysis [489]. The methods are based on the direct proportionality between the current and the concentration of the electroactive species, and exploit the ease and precision of measuring electric currents. Voltammetry is suitable for concentrations at or above ppm level. The sensitivity is often much higher than can be obtained with classical titrations. The sensitivity of voltammetric... [Pg.669]

The radiation measuring unit built into the weathering device must be calibrated at regular intervals. Two methods are commonly used for this purpose either a calibrated xenon lamp is used, which generates an irradiance indicated in the calibration certificate on the surface of the samples at a specific level of electric power, or the radiation measuring device must be recalibrated by the manufacturer at regular intervals. [Pg.724]

The electrophoretic motion is either measured microscopically or by light scattering. The former way is called microelectrophoresis and usually employs ultramicroscopes when dealing with colloidal particle systems. The optical instrumentation can be identical to that of DUM, while the software has to be modified because only the displacement in the direction of the electric field is relevant. The method yields a number weighted distribution of zeta-potentials. Similar to DUM, a sufficiently large number of trajectories has to be evaluated in order to keep the statistical uncertainty within an acceptable level. Moreover, the method may be insensitive to weak scatterers within a polydisperse colloidal suspension. [Pg.53]

The theory of sonic-electronic level measurement is fundamentally based on a sound wave emission source from a transmitter, and a reflection of the sonic wave pulse to a receiver. Measurement of the transit time of this sound pulse and its correlation with electrical impulses provide a means for liquid level detection. Two basic designs operating on this principle use the vapor phase and the liquid phase methods. As most of the attention is currently devoted to the latter type system, this discussion deals exclusively with ultrasonic gaging over a liquid path. [Pg.403]

For large systems the parametrisation method has to be efficient and provide fast convergence. The reference values can be obtained either by higher level first principles - calculations or, preferably, from the experimental measurements of certain properties. Useful reference quantities are energy differences among frontier molecular orbital levels, the electric dipole moment, the symmetry and eharge distribution of specifie orbitals, fragment populations, etc. For instanee, the cost (or penalty) function can be defined as... [Pg.119]

Wlien an electrical coimection is made between two metal surfaces, a contact potential difference arises from the transfer of electrons from the metal of lower work function to the second metal until their Femii levels line up. The difference in contact potential between the two metals is just equal to the difference in their respective work fiinctions. In the absence of an applied emf, there is electric field between two parallel metal plates arranged as a capacitor. If a potential is applied, the field can be eliminated and at this point tire potential equals the contact potential difference of tlie two metal plates. If one plate of known work fiinction is used as a reference electrode, the work function of the second plate can be detennined by measuring tliis applied potential between the plates [ ]. One can detemiine the zero-electric-field condition between the two parallel plates by measuring directly the tendency for charge to flow through the external circuit. This is called the static capacitor method [59]. [Pg.1894]

In general, low level detection is masked by the noise level inherent in any measuring device. Electrochemical methods are susceptible to electrical interference from external sources, variations in reference electrode parameters resulting from aging or contamination, and interference from redox... [Pg.110]

Guidelines on t ualily management and quality system elements Test code for the measurement of airborne noise emitted by rotating electrical machines Engineering method for free field conditions over a reflecting plane Survey method Determination of sound power levels of noise sources 14004/1991 BS EN ISO 9004/1994-1/1994 BS 7458-1/1991 BS 7458-2/1991 B.S 4196 9004/1987 1680-1/1986 1680-2/1986. 3740... [Pg.271]


See other pages where Level measurements electrical methods is mentioned: [Pg.763]    [Pg.18]    [Pg.142]    [Pg.61]    [Pg.119]    [Pg.130]    [Pg.61]    [Pg.587]    [Pg.568]    [Pg.936]    [Pg.243]    [Pg.266]    [Pg.113]    [Pg.941]    [Pg.113]    [Pg.767]    [Pg.216]    [Pg.435]    [Pg.234]    [Pg.261]    [Pg.73]    [Pg.27]    [Pg.388]    [Pg.73]    [Pg.131]    [Pg.41]    [Pg.594]    [Pg.412]    [Pg.1444]    [Pg.310]    [Pg.385]    [Pg.589]    [Pg.1269]    [Pg.140]    [Pg.189]    [Pg.188]   


SEARCH



Electric measurements

Electrical measurement

Electricity measurement

Electricity measuring

Level measurements

Level method

© 2024 chempedia.info