Current, electrical measurement

Polar Cell Systems for Membrane Transport Studies Direct current electrical measurement in epithelia steady-state and transient analysis, 171, 607 impedance analysis in tight epithelia, 171, 628 electrical impedance analysis of leaky epithelia theory, techniques, and leak artifact problems, 171, 642 patch-clamp experiments in epithelia activation by hormones or neurotransmitters, 171, 663 ionic permeation mechanisms in epithelia biionic potentials, dilution potentials, conductances, and streaming potentials, 171, 678 use of ionophores in epithelia characterizing membrane properties, 171, 715 cultures as epithelial models porous-bottom culture dishes for studying transport and differentiation, 171, 736 volume regulation in epithelia experimental approaches, 171, 744 scanning electrode localization of transport pathways in epithelial tissues, 171, 792. [Pg.450]

Other methods attempt to probe the stmcture of the foam indirectly, without directly imaging it. Eor example, since the Hquid portion of the foam typically contains electrolytes, it conducts electrical current, and much work has been done on relating the electrical conductivity of a foam to its Hquid content, both experimentally (15) and theoretically (16). The value of the conductivity depends in a very complex fashion on not only the Hquid content and its distribution between films and borders, but the geometrical stmcture of the bubble packing arrangement. Thus electrical measurements offer only a rather cmde probe of the gas Hquid ratio, a quantity that can be accurately estimated from the foam s mass density. [Pg.429]

In a similar fashion. Thermally Stimulated Current spectrometry (TSC) makes use of an appHed d-c potential that acts as the stress to orient dipoles. The temperature is then lowered to trap these dipoles, and small electrical currents are measured during heating as the dipoles relax. The resulting relaxation maps have been related to G and G" curves obtained by dynamic mechanical analysis (244—246). This technique, long carried out only in laboratory-built instmments, is available as a commercial TSC spectrometer from Thermold Partners L.P., formerly Solomat Instmments (247). [Pg.194]

In all electrical measurements, current and voltage measuring instruments with two terminals are employed. The object being measured similarly has two termi-... [Pg.79]

The cathodic protection of reinforcing steel and stray current protection measures assume an extended electrical continuity through the reinforcing steel. This is mostly the case with rod-reinforced concrete structures however it should be verified by resistance measurements of the reinforcing network. To accomplish this, measuring cables should be connected to the reinforcing steel after removal of the concrete at different points widely separated from each other. To avoid contact resistances, the steel must be completely cleaned of rust at the contact points. [Pg.433]

Magnesium anodes are usually built into the object to be protected through isolating sockets or holes (see Fig. 20-6) and joined to them with cables. They must be readily accessible and easily exchangeable for convenient control [4]. The directions for use have to indicate the necessity for an inspection after 2 years of operation. During operation, control can be exercised by electrical measurements (current, resistance). In addition, acoustic and optical methods exist to determine the amount of anode consumption [4]. The life of the anodes is usually more than 5 years (see Section 6.6). [Pg.451]

Electrical measurements on devices with different layer thickness have shown that the diode current depends on the applied field rather than the drive voltage. This is similar to what has been observed with our alternating PPV copolymers [68]. It indicates that field-driven injection determines the electrical characteristics. From Figure 16-39 it is evident that U-OPV5 has the lowest onset for both current and emission. By means of Fowler-Nordhcini analysis of the /-V -charac-teristics and optical absorption measurements, wc estimated the injection barrier for holes and the HOMO-LUMO gap, respectively [119]. The results of... [Pg.624]

The method just described leads to the mean specific heats over a fairly large range. Nernst, Koref, and Lindemann (1910) have recently described a method of measuring the true specific heat at a given low temperature. The substance is contained in a block of copper cooled to the requisite temperature in liquid carbon dioxide, liquid air, etc., and energy is supplied by a heating spiral of platinum wire carrying an electric current, the measurement of the resistance of which serves at the same time to determine the temperature. [Pg.14]

By contrast, the technique of DETA is based on electrical measurements. In this technique polymers are exposed to an alternating current and changes... [Pg.50]

Holz, M Lucas, O Muller, C, NMR in the Presence of an Electric Current, Simultaneous Measurements of Ionic Mobilities, Transference Numbers, and Self-Diffusion Coefficients Using an NMR Pulsed-Gradient Experiment, Journal of Magnetic Resonance 58, 294, 1984. Hooper, HH Baker, JP Blanch, HW Prausnitz, JM, Swelling Equilibria for Positively Ionized Polyacrylamide Hydrogels, Macromolecules 23, 1096, 1990. [Pg.613]

Electrophysiological Experiments. Guinea pig myocardial cells prepared as described previously 24) were superfused at 37 C with a Tyrode solution. Electrical properties of the myocytes were examined by the patch-clamp methods (25) using fire-polished pipettes. The current was measured by means of a patch-clamp amplifier, stored on the tape through a digital PCM data recording system, and analyzed with a computer. [Pg.134]

FIG. 3 (a) Block schematic of the typical instrumentation for SECM with an amperometric UME tip. The tip position may be controlled with various micropositioners, as outlined in the text. The tip potential is applied, with respect to a reference electrode, using a potential programmer, and the current is measured with a simple amplifier device. The tip position may be viewed using a video microscope, (b) Schematic of the submarine UME configuration, which facilitates interfacial electrochemical measurements when the phase containing the UME is more dense than the second phase. In this case, the glass capillary is attached to suitable micropositioners and electrical contact is made via the insulated copper wire shown. [Pg.294]

By making use of the analogies between the molecular transport of the various conserved quantities, describe how you would set up an experiment to solve each of the following problems by making electrical measurements (e.g., describe the design of the experiment, how and where you would measure voltage and current, and how the measured quantities are related to the desired quantities). [Pg.13]

The simplest analytical method is direct measurement of arsenic in volatile methylated arsenicals by atomic absorption [ 11 ]. A slightly more complicated system, but one that permits differentiation of the various forms of arsenic, uses reduction of the arsenic compounds to their respective arsines by treatment with sodium borohydride. The arsines are collected in a cold trap (liquid nitrogen), then vaporised separately by slow warming, and the arsenic is measured by monitoring the intensity of an arsenic spectral line, as produced by a direct current electrical discharge [1,12,13]. Essentially the same method was proposed by Talmi and Bostick [10] except that they collected the arsines in cold toluene (-5 °C), separated them on a gas chromatography column, and used a mass spectrometer as the detector. Their method had a sensitivity of 0.25 xg/l for water samples. [Pg.457]

Important electrical informations about OLEDs, such as charge transport, charge injection, carrier mobility, etc., can be obtained from bias-dependent impedance spectroscopy, which in turn provides insight into the operating mechanisms of the OLED [14,15,73,75 78]. Campbell et al. reported electrical measurements of a PLED with a 50-nm-thick emissive layer [75], Marai et al. studied electrical measurement of capacitance-voltage and impedance frequency of ITO/l,4-Mv-(9-anthrylvinyl)-benzene/Al OLED under different bias voltage conditions [76], They found that the current is space-charge limited with traps and the conductivity exhibits power-law frequency dependence. [Pg.627]

The generation of small electrical currents in soil is possible and may affect any electrical measurement made therein. Recent theoretical and... [Pg.194]

I-3.6.2 Electronic control, monitoring, and hydrogen gas measurement equipment shall be properly grounded and isolated from piping to help prevent overpressure/ accidental shutoff situations caused by equipment failure due to lightning strikes and electrical transients and to prevent safety hazards caused by fault currents. Electrical isolation equipment for corrosion control purposes should not be installed in buildings unless specifically designed to be used in combustible atmospheres. [Pg.171]

Current is a measure of electron flow rate in an electrical circuit, analogous to water flow rate through a pipe, and is symbolized by I. Current is measured in amperes (amps), symbolized as A miUiamperes (milliamps), symbolized as mA or microamperes (microamps), symbolized as ptA. An ampere is an electron flow of 6.23 xlO18 electrons per second passing through the circuit. [Pg.156]

The electrical current used by the motor is an important indicator of the performance of the extruder. The current as measured in amperage is directly proportional to the torque applied to the motor shaft and also to the screw. The motor current can be used to estimate the power and specific energy that are dissipated by the screw. The variation in the motor current with time is also an indicator of the stability of the extruder. Numerous examples of the motor current stability and process stabilities are presented in Chapter 12. [Pg.435]


See other pages where Current, electrical measurement is mentioned: [Pg.153]    [Pg.358]    [Pg.362]    [Pg.106]    [Pg.115]    [Pg.236]    [Pg.189]    [Pg.1]    [Pg.650]    [Pg.73]    [Pg.261]    [Pg.92]    [Pg.92]    [Pg.358]    [Pg.371]    [Pg.23]    [Pg.307]    [Pg.338]    [Pg.42]    [Pg.11]    [Pg.408]    [Pg.231]    [Pg.163]    [Pg.231]    [Pg.334]    [Pg.19]    [Pg.546]    [Pg.304]    [Pg.294]    [Pg.397]    [Pg.78]   
See also in sourсe #XX -- [ Pg.505 ]




SEARCH



Alternating currents, polymer electricity measurement techniques

Current Measuring

Current measurement

Electric current

Electric current, unit measurement

Electric measurements

Electrical current

Electrical current amperes , measuring electron flow

Electrical current measuring

Electrical current measuring

Electrical measurement

Electricity measurement

Electricity measuring

Measured current