Leak valve method

The following discussion provides a plant caculation method for lower explosion limit concentrations for flare stacks or leaking valves that could ignite. [Pg.183]

The working method is strongly dependent on the leak detector connection in fine vacuum the detector can be connected directly whereas in gross vacuum throttles, leak valves, traps, filters or cold-traps have to be inserted. [Pg.177]

A low-pressure switch can also be used in conjunction with a thermostat and a solenoid valve in the pump-down circuit. In this method of control, the thermostat does not stop the compressor but de-energizes the liquid line solenoid valve to stop the supply of refrigerant to the evaporator. The compressor continues to run and pumps down the evaporator until stopped by the low-pressure switch. When the thermostat again calls for cooling, it opens the solenoid valve, liquid enters the evaporator and the low-pressure switch will close again to restart the compressor. This method is used to ensure that the evaporator is kept clear of liquid when the plant is off. If there is any leak at the solenoid valve, it will cause the... [Pg.106]

Methods that are used to prevent VCEs include keeping low inventories of volatile, flammable materials, using process conditions that minimize flashing if a vessel or pipeline is ruptured, using analyzers to detect leaks at low concentrations, and installing automated block valves to shut systems down while the spill is in the incipient stage of development. [Pg.282]

Vacuum technology puts great demands on the functioning and reliability of the valves, which are often needed in large numbers in a plant. The demands are fulfilled only if correct shut-off devices are installed for each application, depending on the method of construction, method of operation, and size. Moreover, in the construction and operation of vacuum plants, factors such as the flow conductance and leak-tightness of valves are of great importance. [Pg.73]

Another method is to get a sample of oil from the top sight glass of the vessel and compare Its shakeout to a sample obtained from the dump valve. Should the oil from the sight glass be cleaner, it is quite possible that there is a hole In the heat exchanger. The same result would show up if there were a leak in the top plate of the treater which separates the gas sec-r,onv or a hole in the upper pan of the down line. [Pg.139]

In general, flooded condenser pressure control is the preferred method to control a tower s pressure. This is so because it is simpler and cheaper than hot-vapor bypass pressure control. Also, the potential problem of a leaking hot-vapor bypass control valve cannot occur. Many thousands of hot-vapor bypass designs have eventually been converted—at no cost—to flooded condenser pressure control. [Pg.160]

If the leak path is tortuous, these techniques do not work well and a leak detector may be more suitable. For example, leaks in swage-type fittings (Section 10.3.C) and valves of various types may be difficult to detect using these methods. [Pg.247]

In contrast with the above situation, chamber pressure becomes an independent programmable variable when a calibrated leak, or successive leaks of different pressure levels, is performed during the lyophilization. A usual way to generate a calibrated leak is to repeatedly inject nitrogen into the chamber so as to maintain the total pressure within a narrow range of values, this independent of the course of ice sublimation or water desorption. Another method for generating a constant pressure inside the chamber is to open and close repeatedly the valve between the condenser and the vacuum pumps, so as to maintain the water vapor pressure within predefined limits. [Pg.381]

There are several ways to pressurize enclosures. One is to apply a slight positive pressure to the enclosure and then seal it with a valve cutoff. Such a system would have a pressure read-out, or audio-visual alert, and a cutoff circuit. With this method a good seal and regular monitoring is necessary because the unit will probably have to be re-pressurized periodically to keep it at proper pressure, as very slow leaks can occur over time. Usually, this method is used when attendants or operators are present. [Pg.35]

Each filled cylinder should be tested for leaks using an appropriate method, such as a leak detection solution applied to the valve area... [Pg.160]


See other pages where Leak valve method is mentioned: [Pg.43]    [Pg.44]    [Pg.43]    [Pg.44]    [Pg.345]    [Pg.237]    [Pg.113]    [Pg.216]    [Pg.231]    [Pg.267]    [Pg.50]    [Pg.615]    [Pg.44]    [Pg.200]    [Pg.707]    [Pg.90]    [Pg.336]    [Pg.2309]    [Pg.196]    [Pg.910]    [Pg.191]    [Pg.139]    [Pg.354]    [Pg.246]    [Pg.1454]    [Pg.238]    [Pg.2064]    [Pg.205]    [Pg.1815]    [Pg.194]    [Pg.9]    [Pg.553]    [Pg.303]    [Pg.267]    [Pg.417]    [Pg.581]    [Pg.180]    [Pg.279]   
See also in sourсe #XX -- [ Pg.44 ]