Laser-induced fluorescence LIF

However, with the advent of lasers, the teclmique of laser-induced fluorescence (LIF) has probably become the single most popular means of detennining product-state distributions an early example is the work by Zare and co-workers on Ba + FLT (X= F, Cl, Br, I) reactions [25]. Here, a tunable laser excites an electronic transition of one of the products (the BaX product in this example), and the total fluorescence is detected as a... [Pg.873]

Tunable visible and ultraviolet lasers were available well before tunable infrared and far-infrared lasers. There are many complexes that contain monomers with visible and near-UV spectra. The earliest experiments to give detailed dynamical infonnation on complexes were in fact those of Smalley et al [22], who observed laser-induced fluorescence (LIF) spectra of He-l2 complexes. They excited the complex in the I2 B <—A band, and were able to produce excited-state complexes containing 5-state I2 in a wide range of vibrational states. From line w idths and dispersed fluorescence spectra, they were able to study the rates and pathways of dissociation. Such work was subsequently extended to many other systems, including the rare gas-Cl2 systems, and has given quite detailed infonnation on potential energy surfaces [231. [Pg.2447]

Direct Measurement of HO, in the Troposphere. Techniques to measure tropospheric concentrations of HO have been reviewed (O Brien Hard, submitted to Advances in Chemistry, 1991) so only a summary will be given here. The most extensively researched technique for [HO ] measurement in the troposphere is based on laser-induced fluorescence (LIF) of HO. This approach has been developed in many configurations directing the laser into the free atmosphere and collecting fluorescence back scatter (LIDAR) (105,106,107) LIF of air sampled at atmospheric pressure... [Pg.83]

Table III. Detection Limits of 0PA/2-ME and NDA/CN Derivatized Amino Acids Using Conventional and Laser-Induced Fluorescence (LIF) Detection... Table III. Detection Limits of 0PA/2-ME and NDA/CN Derivatized Amino Acids Using Conventional and Laser-Induced Fluorescence (LIF) Detection...
In order to relate material properties with plasma properties, several plasma diagnostic techniques are used. The main techniques for the characterization of silane-hydrogen deposition plasmas are optical spectroscopy, electrostatic probes, mass spectrometry, and ellipsometry [117, 286]. Optical emission spectroscopy (OES) is a noninvasive technique and has been developed for identification of Si, SiH, Si+, and species in the plasma. Active spectroscopy, such as laser induced fluorescence (LIF), also allows for the detection of radicals in the plasma. Mass spectrometry enables the study of ion and radical chemistry in the discharge, either ex situ or in situ. The Langmuir probe technique is simple and very suitable for measuring plasma characteristics in nonreactive plasmas. In case of silane plasma it can be used, but it is difficult. Ellipsometry is used to follow the deposition process in situ. [Pg.79]

Several characteristics of the metal beam have been studied in detail. It is well known that metal clusters and metal oxides are formed as a result of the ablation process. However, these potentially interfering species have been studied in detail130 and it has been concluded that they do not introduce any doubt as to the validity of the experimental results. Much more important than cluster or oxide formation are the atomic electronic state populations of the metal beams. For each metal reactant, these have been characterized using laser-induced fluorescence (LIF) excitation spectroscopy. For Y, only the two spin-orbit states of the ground electronic state (a Dz/2 and a D-3,/2) were observed.123... [Pg.228]

The general principle of detection of free radicals is based on the spectroscopy (absorption and emission) and mass spectrometry (ionization) or combination of both. An early review has summarized various techniques to detect small free radicals, particularly diatomic and triatomic species.68 Essentially, the spectroscopy of free radicals provides basic knowledge for the detection of radicals, and the spectroscopy of numerous free radicals has been well characterized (see recent reviews2-4). Two experimental techniques are most popular for spectroscopy studies and thus for detection of radicals laser-induced fluorescence (LIF) and resonance-enhanced multiphoton ionization (REMPI). In the photochemistry studies of free radicals, the intense, tunable and narrow-bandwidth lasers are essential for both the detection (via spectroscopy and photoionization) and the photodissociation of free radicals. [Pg.472]

Using the same PAbs an optical biosensor system has been developed for 2,4,6-TCP [224]. The principle is the detection of laser-induced fluorescence (LIF) in single microdroplets by a homogeneous quenching fluorescence immunoassay (QFIA). The competitive immunoassay occurs in microdroplets (d=58.4 mm) produced by a piezoelectric generator system. A continuous Ar ion laser (488 nm) excites the fluorescent tracer and its fluorescence is detected by a spectrometer attached to a cooled, charge-coupled device (CCD) camera... [Pg.162]

Concentrations of OH and HO2 were determined, in situ, using Laser Induced Fluorescence (LIF) at low pressure, (FAGE technique). HO2 cannot be detected directly by LIF, and was converted to OH by titration with NO directly below the sampling nozzle. The detection limit for the FAGE instrument during SOAPEX-2, determined by calibration in the field, was 1.4 xlO5 molecule cm-3 for OH and 5.4x 105 molecule cm-3 for HO2. A description of the instrument, as set up in previous field campaigns and dur-... [Pg.3]

Capillary electrophoresis (CE) either coupled to MS or to laser-induced fluorescence (LIF) is less often used in metabolomics approaches. This method is faster than the others and needs a smaller sample size, thereby making it especially interesting for single cell analysis [215] The most sensitive mass spectrometers are the Orbitrap and Fourier transform ion cyclotron resonance (FT-ICR) MS [213]. These machines determine the mass-to-charge ratio of a metabolite so accurate that its empirical formula can be predicted, making them the techniques of choice for the identification of unknown peaks. [Pg.151]

Capillary electrophoresis coupled with a laser-induced fluorescence (LIF) detector has also been applied for the analysis of copper chlorophyll in olive oils. Samples were... [Pg.314]

When compared to fluorescence detectors for HPLC, the design of a fluorescence detector for CE presents some technical problems. In order to obtain acceptable sensitivity, it is necessary to focus sufficient excitation light on the capillary lumen. This is difficult to achieve with a conventional light source but is easily accomplished using a laser. The most popular source for laser-induced fluorescence (LIF) detection is the argon ion laser, which is stable and relatively inexpensive. The 488-nm argon ion laser line is close to the desired excitation wavelength for several common fluorophores. The CLOD for a laser-based fluorescence detector can be as low as 10 12 M. [Pg.173]

Valuable findings on the electronic ground and excited states of clusters have been derived from laser-induced multi-photon ionization (MPl) investigations, such as laser-induced fluorescence (LIF) and REMPI. This latter technique is particularly promising since it enables mass selection of cluster species and their spectral and thermochemical characterization. The complex is excited from its electronic ground state from a photon and then ionized by a second photon of equal or different frequency, near threshold to avoid cluster fragmentation. ... [Pg.159]

Microdialysis is a sampling technique that must be coupled with an analytical method to identify and quantify chemical components of the dialysate. The samples can be analyzed immediately upon collection (i.e., online), or they can be stored (—80°C) for future analysis. Only analytical techniques sensitive enough to measure both small sample volumes and low concentrations of substances can be used to measure compounds in dialysate samples. High-performance liquid chromatography (HPLC) or capillary electrophoresis (CE) combined with ultraviolet (UV), electrochemical (EC), or laser-induced fluorescence (LIF)... [Pg.222]

NIR methods are not the only on-line applications for blend monitoring FT-Raman " and laser induced fluorescence (LIF) have been utilized. Refer to Chapter 11 for a comprehensive review of LIF. As stated herein, NIRS is well established as an effective and advantageous means to deem blend homogeneity and blending end point, however there are circumstances in which NIR is insufficient. For example, LIF can be more suitable for blends with low drug load. Lai and Cooney illustrated in a lab-scale experiment that LIE yielded a limit of detection below 0.02% w/w for a given API. ... [Pg.451]


See other pages where Laser-induced fluorescence LIF is mentioned: [Pg.2958]    [Pg.17]    [Pg.234]    [Pg.131]    [Pg.155]    [Pg.190]    [Pg.207]    [Pg.266]    [Pg.398]    [Pg.415]    [Pg.274]    [Pg.562]    [Pg.88]    [Pg.126]    [Pg.221]    [Pg.20]    [Pg.366]    [Pg.394]    [Pg.434]    [Pg.13]    [Pg.50]    [Pg.606]    [Pg.1077]    [Pg.199]    [Pg.48]    [Pg.15]    [Pg.50]   
See also in sourсe #XX -- [ Pg.317 ]

See also in sourсe #XX -- [ Pg.255 , Pg.257 ]

See also in sourсe #XX -- [ Pg.287 ]




SEARCH



Fluorescence laser induced

Induced fluorescence

LIF

LIFS (

Laser Induced Fluorescence (LIF) and Scattering Method (Lorenz-Mie, Rayleigh, Raman)

Laser fluorescence

Laser induced

Lasers laser-induced fluorescence

Product State Analysis by Laser-induced Fluorescence (LIF)