Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Kinetics dispersion measurements

In general, the sensitivity of FIA is less than that for conventional methods of analysis for two principal reasons. First, as with chemical kinetic methods, measurements in FIA are made under nonequilibrium conditions when the signal has yet to reach its maximum value. Second, dispersion of the sample as it progresses through the system results in its dilution. As discussed earlier, however, the variables that influence sensitivity are known. As a result the FIA manifold can be designed to optimize the sensitivity of the analysis. [Pg.658]

FIA is capable of very high precision, better than 1%, as a result of very controlled sample dispersion in a continuous flow stream. Kinetic FIA measurements can be made by precisely stopping (under computer control) the flow of the analyte product in the detector cell at a position corresponding to the peak or some point past it, depending on concentrations. Then the change of signal, for example, absorbance, is recorded for a period of time to obtain the rate. The slope of this recorded signal is plotted for different concentrations to prepare a calibration curve. [Pg.672]

Chemical Reaction Measurements. Experimental studies of incineration kinetics have been described (37—39), where the waste species is generally introduced as a gas in a large excess of oxidant so that the oxidant concentration is constant, and the heat of reaction is negligible compared to the heat flux required to maintain the reacting mixture at temperature. The reaction is conducted in an externally heated reactor so that the temperature can be controlled to a known value and both oxidant concentration and temperature can be easily varied. The experimental reactor is generally a long tube of small diameter so that the residence time is well defined and axial dispersion may be neglected as a source of variation. Off-gas analysis is used to track both the disappearance of the feed material and the appearance and disappearance of any products of incomplete combustion. [Pg.57]

Radial density gradients in FCC and other large-diameter pneumatic transfer risers reflect gas—soHd maldistributions and reduce product yields. Cold-flow units are used to measure the transverse catalyst profiles as functions of gas velocity, catalyst flux, and inlet design. Impacts of measured flow distributions have been evaluated using a simple four lump kinetic model and assuming dispersed catalyst clusters where all the reactions are assumed to occur coupled with a continuous gas phase. A 3 wt % conversion advantage is determined for injection feed around the riser circumference as compared with an axial injection design (28). [Pg.513]

The silica dispersion showed the smallest retention volume. It should be noted, however, that the authors reported that the silica dispersion required sonicating for 5 hours before the silica was sufficiently dispersed to be used as "pseudo-solute". The retention volume of the silica dispersion gave the value of the kinetic dead volume, /.e., the volume of the moving portion of the mobile phase. It is clear that the difference between the retention volume of sodium nitroprusside and that of the silica dispersion is very small, and so the sodium nitroprusside can be used to measure the kinetic dead volume of a packed column. From such data, the mean kinetic linear velocity and the kinetic capacity ratio can be calculated for use with the Van Deemter equation [12] or the Golay equation [13]. [Pg.41]

The crystallization kinetics defines the open time of the bond. For automated industrial processes, a fast crystallizing backbone, such as hexamethylene adipate, is often highly desirable. Once the bond line cools, crystallization can occur in less than 2 min. Thus, minimal time is needed to hold or clamp the substrates until fixturing strength is achieved. For specialty or non-automated processes, the PUD backbone might be based on a polyester polyol with slow crystallization kinetics. This gives the adhesive end user additional open time, after the adhesive has been activated, in which to make the bond. The crystallization kinetics for various waterborne dispersions were determined by Dormish and Witowski by following the Shore hardness. Open times of up to 40 min were measured [60]. [Pg.791]

Measurement of the absorption rate of carbon dioxide in aqueous solutions of sodium hydroxide has been used in some of the more recent work on mass-transfer rate in gas-liquid dispersions (D6, N3, R4, R5, V5, W2, W4, Y3). Although this absorption has a disadvantage because of the high solubility of C02 as compared to 02, it has several advantages over the sulfite-oxidation method. For example, it is relatively insensitive to impurities, and the physical properties of the liquid can be altered by the addition of other liquids without appreciably affecting the chemical kinetics. Yoshida and... [Pg.301]

Isothermal a—time curves were sigmoid [1024] for the anhydrous Ca and Ba salts and also for Sr formate, providing that nucleation during dehydration was prevented by refluxing in 100% formic acid. From the observed obedience to the Avrami—Erofe ev equation [eqn. (6), n = 4], the values of E calculated were 199, 228 and 270 kJ mole"1 for the Ca, Sr and Ba salts, respectively. The value for calcium formate is in good agreement with that obtained [292] for the decomposition of this solid dispersed in a pressed KBr disc. Under the latter conditions, concentrations of both reactant (HCOJ) and product (CO3") were determined by infrared measurements and their variation followed first-order kinetics. [Pg.211]

Twenty-three kinetics have been carried out at 25°C for pH values from 8.25 to 11.25. The rate constant, calculated as the average of all the ks, was of 27.2 9.0 mol 1 min. The pH correction according to equation (2) was not perfect, as there was a tendency to obtain higher k values at lower pH values. However, this was specially true for extreme vdues of our pH range, where the buffer capacity of ethanolamine was limited (higher pHs) or the reaction proceeded very slowly (low pHs), impairing the precision of the data. Another factor that might explain the dispersion of the data is lack of precision of pH measurement (no better than 0.02 pH units). [Pg.607]

J. P., Matlosz, M., MicroChannel reactors for kinetic measurement influence of diffusion and dispersion on experimental accuracy, in Matlosz, M., Ehreeld, W, Baselt, J. P. (Eds.), Microreaction Technology - IMRET 5 Proc. 5th International Conference on Microreaction Technology, Springer-Verlag, Berlin (2001), pp. 131-140. [Pg.255]

A comprehensive kinetic model addressing all the findings has not been developed. Some of the reported rate equations consider the self-poisoning effect of the reactant compounds, some other that effect of ammonia, and so on so forth. The reported data is dispersed with a variety of non-comparable conditions and results. The adsorption of the poisoning compounds has been modeled assuming one or two-sites on the catalyst surface however, the applicability of these expressions also needs to be addressed to other reacting systems to verity its reliability. The model also needs of validated adsorption parameters, difficult to measure under the operating conditions. [Pg.26]


See other pages where Kinetics dispersion measurements is mentioned: [Pg.35]    [Pg.2933]    [Pg.3803]    [Pg.139]    [Pg.138]    [Pg.191]    [Pg.615]    [Pg.661]    [Pg.487]    [Pg.2954]    [Pg.2962]    [Pg.2966]    [Pg.333]    [Pg.455]    [Pg.233]    [Pg.308]    [Pg.198]    [Pg.260]    [Pg.266]    [Pg.319]    [Pg.355]    [Pg.120]    [Pg.149]    [Pg.21]    [Pg.534]    [Pg.538]    [Pg.456]    [Pg.42]    [Pg.254]    [Pg.590]    [Pg.151]    [Pg.273]    [Pg.274]    [Pg.145]    [Pg.384]    [Pg.297]    [Pg.205]    [Pg.341]    [Pg.444]   
See also in sourсe #XX -- [ Pg.106 , Pg.111 ]




SEARCH



Dispersion kinetics

Dispersion measurements

Dispersion measures

Dispersities kinetics

Kinetic measurement

Kinetics measurements

© 2024 chempedia.info