Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Isee Systems

K. Grob and M. Biedeimann, Vapoi ising systems foi large volume injection oi on-line ti ansfer into gas cltromatography classification, critical remarks and suggestions , 7. Chromatogr. 750 11-23 (1996). [Pg.375]

It should be realized that unlike the study of equilibrium thermodynamics for which a model is often mapped onto Ising system, elementary mechanism of atomic motion plays a deterministic role in the kinetic study. In an actual alloy system, diffusion of an atomic species is mainly driven by vacancy mechanism. The incorporation of the vacancy mechanism into PPM formalism, however, is not readily achieved, since the abundant freedom of microscopic path of atomic movement demands intractable number of variational parameters. The present study is, therefore, limited to a simple spin kinetics, known as Glauber dynamics [14] for which flipping events at fixed lattice points drive the phase transition. Hence, the present study for a spin system is regarded as a precursor to an alloy kinetics. The limitation of the model is critically examined and pointed out in the subsequent sections. [Pg.84]

Stella isee Systems (formerly High Performance Systems) http //www.hps-inc.com/... [Pg.520]

If the ordered, crystalline regions are cross sections of bundles of chains and the chains go from one bundle to the next (although not necessarily in the same plane), this is the older fringe-micelle model. If the emerging chains repeatedly fold buck and reenter the same bundle in this or a different plane, this is the folded-chain model. In either case the mechanical deformation behavior of such complex structures is varied and difficult to unravel unambiguously on a molecular or microscopic scale. In many respects the behavior of crystalline polymers is like that of two-ph ise systems as predicted by the fringed-micelle- model illustrated in Figure 7, in which there is a distinct crystalline phase embedded in an amorphous phase (134). [Pg.23]

The actual ISE system consists of internal reference electrode 2, internal solution of the ion-selective electrode 2 and the membrane. This system is immersed in andysed solution (analyte) 1, in which reference electrode 1 is also immersed, usually connected through a liquid bridge. The electromotive force of cell (3.1.1) is... [Pg.33]

The selectivity coefficient was defined in chapter 3 and several theoretical relationships were given for this quantity for various ISE systems. Several methods have been proposed [38, 120,123, 135] for the determination of selectivity coefficients two basic methods were recommended by the lUPAC Commission for Analytical Nomenclature [138],... [Pg.83]

Nitrate ISEs can also be used for determination of nitrogen oxides after oxidation to the pentavalent form (for example with H2O2) [39, 41, 101, 109, 150]. The nitrate ISE system is also useful for 2,4-dichlorophenoxyacetate [73] and for tetrathionate [215]. [Pg.191]

The previous chapters dealt with ISE systems at zero current, i.e. at equilibrium or steady-state. The properties of the interface between two immiscible electrolyte solutions (ITIES), described in sections 2.4 and 2.5, will now be used to describe a dynamic method based on the passage of electrical current across ITIES. Voltammetry at ITIES (for a survey see [3, 8, 9, 10, 11, 12,18]) is an inverse analogue of potentiometry with liquid-membrane ISEs and thus forms a suitable conclusion to this book. [Pg.208]

There are essential differences between the systems we have presented here, even in the limit of very strong anisotropy. The RKKY spin glasses are Heisenberg systems with random unidirectional anisotropy. Ferrofluids frozen under zero field are Heisenberg systems with random uniaxial anisotropy, while an Ising system is characterized by parallel uniaxial anisotropy. [Pg.216]

In 1996, the ISEE system was used to remove 200 g of hexavalent chromium from 16 yd of soil at the U.S. Department of Energy s (DOE s) Unlined Chromic Acid Pit located at the Sandia National Laboratory s (SNL s) Chemical Waste Landfill in Albuquerque, New Mexico. The treatment costs for this 4-week demonstration were 1368/yd. According to the U.S. EPA, these costs were calculated for the ISEE prototype used during the demonstration. The costs for a full-scale system would be lower due to design improvements and efficiency of scale (D22781Q, pp. 65, 66 D22758R, pp. 44-51). [Pg.943]

Table 1. Comparison of the critical exponents of NIPA gel with some known Ising systems. The number in the parentheses indicates the error of the corresponding exponent. The row next to the last is obtained directly by using an = —0.05. The last row is the Fisher renormalized results... Table 1. Comparison of the critical exponents of NIPA gel with some known Ising systems. The number in the parentheses indicates the error of the corresponding exponent. The row next to the last is obtained directly by using an = —0.05. The last row is the Fisher renormalized results...
The ISE systems of all three analysers measured lithium in undiluted serum as direct measurements. Automated system calibration and calculation of the results were in-built in all the instruments. The lithium measurement range of the Cobas Integra 700 ISE module was from 0.10 mmol/l up to 4.00 mmol/l. According to the manufacturer s specifications the linear measurement range of the Kone Microlyte 6 ISE analyser was from 0.20 mmol/l to 4.00 mmol/l and for the Chiron 654 ISE from 0.20 mmol/l to 5.00 mmol/l. [Pg.103]

M. Suzuki (1976) Relationship between d-dimensional quantal spin systems and (d-l-l)-dimensional Ising systems - Equivalence, Critical Exponents and Systematic Approximants of the Partition Fimction and Spin Correlations. Prog. Theor. Phys. 56, p. 1454... [Pg.638]

The NH4 produced is then detected by either of the ISE systems mentioned above. Some problems exist for the NH4 ISE because of interference by Na" " and K" " ions which are present in blood. [Pg.501]

At this point, in an effort to summarize the most important ISE systems available for biomedical studies, Table 1 is presented. The table lists the ISEs according to their classification and provides information on the membrane compositions used to construct the electrodes as well as some of their... [Pg.10]

One big difference between one- and two-dimensional systems is that whereas the former never order above 0 K (without interchain interactions), it is possible for a two-dimensional Ising system to order at finite temperature. Onsager has examined such a system for S = 1/2 and found theoretical evidence for ordering, on a square lattice and even if the coupling anisotropy in the two directions on a quadratic lattice (defined to be ]/] ) is 100. An example that behaves as a two-dimensional Ising antiferromagnet is CsslCoBrs]. " ... [Pg.180]


See other pages where Isee Systems is mentioned: [Pg.652]    [Pg.653]    [Pg.656]    [Pg.657]    [Pg.662]    [Pg.359]    [Pg.360]    [Pg.116]    [Pg.527]    [Pg.339]    [Pg.363]    [Pg.34]    [Pg.4]    [Pg.19]    [Pg.256]    [Pg.164]    [Pg.165]    [Pg.165]    [Pg.88]    [Pg.95]    [Pg.111]    [Pg.117]    [Pg.34]    [Pg.35]    [Pg.2465]    [Pg.172]    [Pg.104]    [Pg.74]    [Pg.11]    [Pg.13]    [Pg.20]   
See also in sourсe #XX -- [ Pg.520 ]




SEARCH



ISE

Ising model classical spin systems

Ising system

© 2024 chempedia.info