Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Iron Subject

Consider a bar of iron subject to an external (tensile) stress of 10 kg mm 2. In this bar there are some corrosion pits. The surrounding atmosphere is moist and acidic. Consider a pit 104nm deep (= /) with a tip having a radius, r, of 10 nm. A rough formula for the initial stress at the tip of a pit is that the external tensile stress there is increased Wr times compared with the tensile stress applied to the specimen. [Pg.269]

When the organism is constantly overloaded with iron, subjective complaints gradually develop (in 5-40% of cases). These present a variety of uncharacteristic features, varying from individual to individual. [Pg.621]

FIGURE 2.5 Maps of the surface distribution of some ions for Armco iron subjected to extensive friction against SBR vulcanizate (brighter color indicates on higher intensity of ion present). [Pg.25]

Type J thermocouples (Table 11.58) are one of the most common types of industrial thermocouples because of the relatively high Seebeck coefficient and low cost. They are recommended for use in the temperature range from 0 to 760°C (but never above 760°C due to an abrupt magnetic transformation that can cause decalibration even when returned to lower temperatures). Use is permitted in vacuum and in oxidizing, reducing, or inert atmospheres, with the exception of sulfurous atmospheres above 500°C. For extended use above 500°C, heavy-gauge wires are recommended. They are not recommended for subzero temperatures. These thermocouples are subject to poor conformance characteristics because of impurities in the iron. [Pg.1216]

With incandescence. Further reaction. Even when subjected to pressure for a considerable length of time also no reaction with red-hot iron. ... [Pg.160]

Glass offers good resistance to strong acid at high temperatures. However, it is subject to thermal shock and a gradual loss in integrity as materials such as iron and siUca are leached out into the acid. Nonmetallic materials such as PTFE, PVDC, PVDF, and furan can be used for nitric acid to a limited degree, but are mainly restricted to weak acid service at ambient to moderate temperatures. [Pg.45]

An important item in this array of matenals is the class known as maraging steels. This group of high nickel martensitic steels contain so Htde carbon that they are often referred to as carbon-free iron—nickel martensites (54). Carbon-free iron—nickel martensite with certain alloying elements is relatively soft and ductile and becomes hard, strong, and tough when subjected to an aging treatment at around 480°C. [Pg.400]

The metal parts of the injection molder, ie, the liner, torpedo, and nozzle, that contact the hot molten resin must be of the noncatalytic type to prevent accelerated decomposition of the polymer. In addition, they must be resistant to corrosion by HCl. Iron, copper, and zinc are catalytic to the decomposition and caimot be used, even as components of alloys. Magnesium is noncatalytic but is subject to corrosive attack, as is chromium when used as plating. Nickel alloys such as Duranickel, HasteUoy B, and HasteUoy C are recommended as constmction materials for injection-molding metal parts. These and pure nickel are noncatalytic and corrosion-resistant however, pure nickel is rather soft and is not recommended. [Pg.440]

Sa.tura.tion Index. Materials of constmction used in pools are subject to the corrosive effects of water, eg, iron and copper equipment can corrode whereas concrete and plaster can undergo dissolution, ie, etching. The corrosion rate of metallic surfaces has been shown to be a function of the concentrations of Cl ,, dissolved O2, alkalinity, and Ca hardness as well as buffer intensity, time, and the calcium carbonate saturation index (35). [Pg.300]

Drinking water suppHed to carbonated soft drink manufacturing faciUties from private or municipal sources must comply with all regulatory requirements. Treated water must meet all U.S. Environmental Protection Agency primary maximum contaminant levels and may also be subject to additional state requirements. Treated water is routinely analyzed for taste, odor, appearance, chlorine, alkalinity, iron, pH, total dissolved soHds, hardness, and microbiological contamination. [Pg.15]

The molecular absoi ption spectra, registered at a lower temperature (e.g. 700 °C for iodide or chloride of potassium or sodium), enable one to find the absorbance ratio for any pair of wavelengths in the measurement range. These ratios can be used as a correction factor for analytical signal in atomic absoi ption analysis (at atomization temperatures above 2000 °C). The proposed method was tested by determination of beforehand known silicon and iron content in potassium chloride and sodium iodide respectively. The results ai e subject to random error only. [Pg.78]

Carbon steel heat exchangers, cast iron water boxes, screens, pump components, service water system piping, standpipes, fire protection systems, galvanized steel, engine components, and virtually all non-stainless ferrous components are subject to significant corrosion in oxygenated water. [Pg.106]

The engine could still be run for demonstration purposes. Suppose that you are called in to assess its safety. We will suppose that a crack 2 cm deep has been found in the connecting rod - a cast-iron rod, 21 feet long, with a section of 0.04 m. Will the crack grow under the cyclic loads to which the connecting rod is subjected And what is the likely life of the structure ... [Pg.163]

A cylindrical tube in a chemical plant is subjected to an excess internal pressure of 6 MN m , which leads to a circumferential stress in the tube wall. The tube wall is required to withstand this stress at a temperature of 510°C for 9 years. A designer has specified tubes of 40 mm bore and 2 mm wall thickness made from a stainless alloy of iron with 15% by weight of chromium. The manufacturer s specification for this alloy gives the following information ... [Pg.286]

A sheet of steel of thickness 0.50 mm is tinplated on both sides and subjected to a corrosive environment. During service, the tinplate becomes scratched, so that steel is exposed over 0.5% of the area of the sheet. Under these conditions it is estimated that the current consumed at the tinned surface by the oxygen-reduction reaction is 2 X 10 A m -. Will the sheet rust through within 5 years in the scratched condition The density of steel is 7.87Mg m . Assume that the steel corrodes to give Fe " ions. The atomic weight of iron is 55.9. [Pg.289]


See other pages where Iron Subject is mentioned: [Pg.806]    [Pg.143]    [Pg.806]    [Pg.157]    [Pg.24]    [Pg.177]    [Pg.272]    [Pg.439]    [Pg.2990]    [Pg.146]    [Pg.250]    [Pg.319]    [Pg.155]    [Pg.303]    [Pg.433]    [Pg.542]    [Pg.432]    [Pg.525]    [Pg.554]    [Pg.556]    [Pg.36]    [Pg.461]    [Pg.189]    [Pg.445]    [Pg.460]    [Pg.134]    [Pg.353]    [Pg.84]    [Pg.249]    [Pg.371]    [Pg.211]    [Pg.459]    [Pg.978]    [Pg.144]    [Pg.218]    [Pg.121]   


SEARCH



All ligands receive a separate subject entry, e.g., 2,4-Pentanedione, iron complex. The headings

Iron carbonyl Subject

Iron chloride 480 Subject

Iron complexes Subject

Iron compounds Subject

Iron derivatives Subject

Iron ions 514 Subject

Iron oxide hydroxides Subject

Iron, tricarbonyl 210 Subject

Nitrogen , iron complexes 334 Subject

SUBJECTS iron 687 sulphate

© 2024 chempedia.info