Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Wire gauge

Metiac wire gauge is 10 times the diameter in millimeters. [Pg.41]

Tubes Standard heat-exchanger tubing is V4, Yh, V2., Yh, %, 1, IV4, and IV2. in in outside diameter (in X 25.4 = mm). Wall thickness is measured in Birmingham wire gauge (BWG) units. (A comprehensive list of tubing characteristics and sizes is given in section 9, table D-7 of TEMA.) The most commonly used tubes in chemical plants and petroleum refineries are 19- and 25-mm (%- and 1-in) outside diameter. Standard tube lengths are 8, 10, 12, 16, and 20 ft, with 20 ft now the most common (ft x 0.3048 = m). [Pg.1070]

The toroid should have an overall wire gauge of 12AWG. I will use 100 strand Litz wire to minimize the skin effeets. [Pg.125]

The primary winding will be wound first, then the two layers of Mylar tape. The seeondaries will be bifilar-wound next and then eovered with two layers of Mylar tape. The wire gauges will be 30AWG for eaeh winding. [Pg.126]

Determining the gauge wire needed on the primary, the supply is required to operate at 18 V at the rated load eurrent, so the primary wire gauge needs to be equivalent to 20AWG. [Pg.171]

The power winding of the inductor (transformer) not only must support the maximum average input current but the output current as well. So, the wire gauge of the winding should be... [Pg.226]

The specification of wires can be confusing. All wires diameters are based upon the American Wire Gauge (AWG) table, published in the early 20th century. The metric countries directly converted these dimension (inches) to millimeters and created what is now the lEC R20 wire table. This is shown below in both measurement systems in Table F-t. [Pg.251]

Note lEC R20 is an intermediate wire gauge eventually to be replaced by lEC R40. [Pg.251]

Wire is often sold in pound spools according to the wire gauge number. That number refers to the diameter of the wire. How many meters are in a 10-lb spool of 12-gauge aluminum wire A 12-gauge wire has a diameter of0.0808 in. Aluminum has a density of 2.70 g/cm3. (V = irr2 )... [Pg.23]

Abbreviation for Standard Wire Gauge (British). Syndiotactic or Syndyotactic... [Pg.63]

The thickness of wire often is measured using a system called the American Wire Gauge (AWG) standard. The smaller the gauge number, the larger the diameter of the wire. For example, 18-gauge copper wire has a diameter of about 0.102 cm 12-gauge copper wire has a diameter of about 0.205 cm. Such small diameters are difficult to measure accurately with a metric ruler. In this experiment, you will plot measurements of mass and volume to find the density of copper. Then, you will use the density of copper to confirm the gauge of copper wire. [Pg.6]

There is a standard called the British Imperial Standard Wire Gauge (SWG) that is used in England and Canada. Research the SWG standard to find out how it differs from the AWG standard. Are they the only standards used for wire gauge ... [Pg.8]

ISWG Imperial Standard Wire Gauge Advisory Planning Group... [Pg.750]

Ballistics Research Laboratory, Aberdeen, Md brown brothers British Patent British Rayon Research Association Brown Sharpe Manufacturing Co (wire gauge) Buildings Research Station (Brit)... [Pg.732]

Table 2.34 American Wire Gauge Size Comparison Chart... Table 2.34 American Wire Gauge Size Comparison Chart...

See other pages where Wire gauge is mentioned: [Pg.359]    [Pg.41]    [Pg.63]    [Pg.27]    [Pg.42]    [Pg.42]    [Pg.46]    [Pg.48]    [Pg.50]    [Pg.116]    [Pg.124]    [Pg.172]    [Pg.227]    [Pg.51]    [Pg.59]    [Pg.226]    [Pg.226]    [Pg.1]    [Pg.731]    [Pg.732]    [Pg.759]    [Pg.773]    [Pg.780]    [Pg.713]    [Pg.183]    [Pg.732]    [Pg.733]    [Pg.760]    [Pg.774]    [Pg.781]    [Pg.166]   


SEARCH



American Wire Gauge standard

American Wire Gauge table

American wire gauge

Gauges of plates, sheets and wires

Gauges, of wires

Standard wire gauges

Wire and sheet metal gauges

© 2024 chempedia.info