Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

International Rectifier

As a first example, we will show how to download a model for a Schottky diode. This example will be the same for any device that uses a. model statement. Thus, you can use this same procedure for BJT s, MOSFETs, and jFETs. For this example, we will obtain the model from International Rectifier. Run your browser and open site www.irf.com ... [Pg.450]

We would like to paste the text we copied into this window. Select Edit and then Paste from the Model Editor menus to replace the selected text with the model copied from International Rectifier ... [Pg.453]

INTERNATIONAL RECTIFIE IR2110 IC INTERNATIONAL RECTIFIE IR2110 IC ... [Pg.590]

INTERNATIONAL RECTIFIE IR2121 INTERNATIONAL RECTIFIE IR2121 ... [Pg.590]

INTERNATIONAL RECTIFIE IRF7105 DIGIKEY INTERNATIONAL RECTIFIE IRF7105 DIGIKEY ... [Pg.590]

The power section in this electronic load will be a N-channel power MOSFET. This design uses an IRF250, manufactured by International Rectifier . If a substitute part is used, pick a MOSFET that has the power, drain-to-source voltage, and current rating required for your range, and try to minimize drain-to-source on resistance (RDSon). The schematic of the power MOSFET and drive circuitry is shown in Fig. 5.1. [Pg.119]

International Rectifier. 1993. Hexfet Power MOSFET Designer s Manual. [Pg.276]

Current flowing in the motor can be monitored using a number of different ICs or power FETs available from any number of suppliers. These devices include current shunt ICs (Maxim, Texas Instruments Zetex), sense FETs (Fairchild Semiconductor), HEX sense power FETs (International Rectifier), and fault-protected switches (fancy MOSFETs, Micrel) to name but a few. Current-shunt ICs are common because they find use in dc-to-dc converters, consequently, a large number of different manufacturers make them in many different forms and flavors (see Fig. 32.17). [Pg.837]

Six caustic soda evaporators were anodically protected against stress corrosion in the aluminum industry in Germany in 1965 [27]. Each evaporator had an internal surface area of 2400 m. The transformer-rectifier had a capacity of 300 AJ 5 V and was operated intermittently for many years. Automatic switching on of the protection current only took place in case of need when the drop in potential reached... [Pg.481]

Further chapters cover in detail the characteristics and applications of galvanic anodes and of cathodic protection rectifiers, including specialized instruments for stray current protection and impressed current anodes. The fields of application discussed are buried pipelines storage tanks tank farms telephone, power and gas-pressurized cables ships harbor installations and the internal protection of water tanks and industrial plants. A separate chapter deals with the problems of high-tension effects on pipelines and cables. A study of costs and economic factors concludes the discussion. The appendix contains those tables and mathematical derivations which appeared appropriate for practical purposes and for rounding off the subject. [Pg.583]

Failure costs - Internal failure costs are essentially the cost of failures identified and rectified before the final product gets to the external customer, such as rework, scrap, design changes. External failure costs include product recall, warranty and product liability claims. [Pg.9]

For columns in which there is a substantial flash of the feed liquid, or in which the feed is a vapor of a different composition than the internal vapor, a collector plate can be installed above the feed point. The purpose of this plate is to provide mixing of the vapor phase in the gas risers so that a more uniform vapor composition enters the rectifying section of the column. [Pg.83]

The inward rectifier K+ channels (Kir) represent this family of channels that conduct K+ ions preferentially in the inward direction than outward. The occlusion of internal vestibule oftheporeby Mg2+ and polyamines contribute to this inward rectification. These channels... [Pg.991]

If, in any boiler plant, the installed treatment processes are unsuitable or inadequate for the needs or if operational problems persist, downstream operational problems certainly will develop in a short time. The extent of these problems and their associated costs are likely to be serious if the external treatment problem is not rectified at the source. In almost all cases, internal chemical treatment cannot totally and economically compensate for lack of pretreatment. [Pg.193]

The recognition of the lack of molecular-level information on electrocatalytic phenomena and the resolve to have this weakness rectified is now firmly established within the electrochemical and surface science communities. This is evidenced by recent international conferences and workshops devoted solely to electrochemical problems (11-4). It is also well-realized that electrochemistry cannot advance further unless the practitioners in this field begin to view electrodesolution processes from a molecular-level perspective. [Pg.2]


See other pages where International Rectifier is mentioned: [Pg.234]    [Pg.590]    [Pg.590]    [Pg.590]    [Pg.261]    [Pg.261]    [Pg.266]    [Pg.219]    [Pg.219]    [Pg.835]    [Pg.234]    [Pg.590]    [Pg.590]    [Pg.590]    [Pg.261]    [Pg.261]    [Pg.266]    [Pg.219]    [Pg.219]    [Pg.835]    [Pg.134]    [Pg.163]    [Pg.164]    [Pg.916]    [Pg.85]    [Pg.231]    [Pg.235]    [Pg.83]    [Pg.139]    [Pg.244]    [Pg.205]    [Pg.376]    [Pg.219]    [Pg.89]    [Pg.98]    [Pg.229]    [Pg.389]    [Pg.34]    [Pg.90]    [Pg.34]    [Pg.50]   
See also in sourсe #XX -- [ Pg.219 ]

See also in sourсe #XX -- [ Pg.450 ]

See also in sourсe #XX -- [ Pg.219 ]

See also in sourсe #XX -- [ Pg.219 ]




SEARCH



© 2024 chempedia.info