Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Integrity intensity

A related measure of the intensity often used for electronic spectroscopy is the oscillator strengdi,/ This is a dimensionless ratio of the transition intensity to tliat expected for an electron bound by Hooke s law forces so as to be an isotropic hanuonic oscillator. It can be related either to the experimental integrated intensity or to the theoretical transition moment integral ... [Pg.1126]

This last transition moment integral, if plugged into equation (B 1.1.2). will give the integrated intensity of a vibronic band, i.e. of a transition starting from vibrational state a of electronic state 1 and ending on vibrational level b of electronic state u. [Pg.1128]

The interpretation of emission spectra is somewhat different but similar to that of absorption spectra. The intensity observed m a typical emission spectrum is a complicated fiinction of the excitation conditions which detennine the number of excited states produced, quenching processes which compete with emission, and the efficiency of the detection system. The quantities of theoretical interest which replace the integrated intensity of absorption spectroscopy are the rate constant for spontaneous emission and the related excited-state lifetime. [Pg.1131]

The vibration frequencies of C-H bond are noticeably higher for gaseous thiazole than for its dilute solutions in carbon tetrachloride or tor liquid samples (Table 1-27). The molar extinction coefficient and especially the integrated intensity of the same peaks decrease dramatically with dilution (203). Inversely, the y(C(2jH) and y(C(5(H) frequencies are lower for gaseous thiazole than for its solutions, and still lower than for liquid samples (cf. Table 1-27). [Pg.61]

There is a degeneracy factor of two associated with a n orbital compared with the nondegeneracy of a (7 orbital, so that it might be expected that the integrated intensity of the second band system would be twice that of each of the other two. However, although the second band system is the most intense, other factors affect the relative intensities so that they are only an approximate guide to orbital degeneracies. [Pg.302]

Percent Crystallinity. For samples that consist of a mixture of crystalline and amorphous material, it is possible to determine the percent of crystallinity by measuring the integrated intensity of sharp Bragg reflections and the integrated intensity of the very broad regions due to the amorphous scattering. [Pg.380]

The amplitude of the elastic scattering, Ao(Q), is called the elastic incoherent structure factor (EISF) and is determined experimentally as the ratio of the elastic intensity to the total integrated intensity. The EISF provides information on the geometry of the motions, and the linewidths are related to the time scales (broader lines correspond to shorter times). The Q and ft) dependences of these spectral parameters are commonly fitted to dynamic models for which analytical expressions for Sf (Q, ft)) have been derived, affording diffusion constants, jump lengths, residence times, and so on that characterize the motion described by the models [62]. [Pg.479]

Here Pyj is the structure factor for the (hkl) diffiaction peak and is related to the atomic arrangements in the material. Specifically, Fjjj is the Fourier transform of the positions of the atoms in one unit cell. Each atom is weighted by its form factor, which is equal to its atomic number Z for small 26, but which decreases as 2d increases. Thus, XRD is more sensitive to high-Z materials, and for low-Z materials, neutron or electron diffraction may be more suitable. The faaor e (called the Debye-Waller factor) accounts for the reduction in intensity due to the disorder in the crystal, and the diffracting volume V depends on p and on the film thickness. For epitaxial thin films and films with preferred orientations, the integrated intensity depends on the orientation of the specimen. [Pg.203]

Surface atomic structure. The integrated intensity of several diffracted beams is measured as a fimction of electron beam energy for different angles of incidence. The measurements are fitted with a model calculation that includes multiple scattering. The atomic coordinates of the surfiice atoms are extracted. (See also the article on EXAFS.)... [Pg.260]

The Beer-Lambert Law of Equation (2) is a simpliftcation of the analysis of the second-band shape characteristic, the integrated peak intensity. If a band arises from a particular vibrational mode, then to the first order the integrated intensity is proportional to the concentration of absorbing bonds. When one assumes that the area is proportional to the peak intensity. Equation (2) applies. [Pg.422]

The absolute sensitivity factors Sx must be determined for this procedure by integrating intensities over time while sputtering suitable pure element samples and determining the crater volume for HF-plasma SNMS the weight loss can also be measured. [Pg.130]

If we further assume that the vibrational wavefunctions associated with normal mode i are the usual harmonic oscillator ones, and r = u + 1, then the integrated intensity of the infrared absorption band becomes... [Pg.276]

Figure 16-46. Integrated intensity of total ( ), broad (O). narrow (I 0, and lincwidlh of total ( ) and narrow (O) cmissioas as a function of excitation energy Tor an annealed thin (300 nm) film of Oocl-OPV5 excitation beam diameter % 1.8 mm. Figure 16-46. Integrated intensity of total ( ), broad (O). narrow (I 0, and lincwidlh of total ( ) and narrow (O) cmissioas as a function of excitation energy Tor an annealed thin (300 nm) film of Oocl-OPV5 excitation beam diameter % 1.8 mm.
The continuous spectrum is thus characterized by a short-wavelength limit and an intensity distribution. Experiments on other target materials have shown that these characteristics are independent of the target material although the integrated intensity increases with atomic number. (See Equation 1-3.) The continuous spectrum, therefore, results generally from the interaction of electrons with matter. Attempts (none completely successful) have been made to treat this interaction theoretically by both classical and quantum mechanics. [Pg.7]

The total power, or integrated intensity,4 of the x-ray beam, in watts, is the product of the (empirical) efficiency11 of x-ray production and cathode-ray power iV or... [Pg.8]

If the experiment to which the calculation refers were actually attempted, several differences would appear. A lost important, the x-ray power would be expended over a vide spectrum. The intensity in Equation-4-10 would be the integrated intensity from the short-wavelength limit to the critical absorption wavelength. /Also, gmax and wka would need to be replaced by values that reflect the wavelength range of the integrated intensity. The net effect of all these differences would be to reduce /k below the value of Equation 4-16, perhaps by as much as ten-fold. [Pg.106]


See other pages where Integrity intensity is mentioned: [Pg.724]    [Pg.1128]    [Pg.1130]    [Pg.1130]    [Pg.1137]    [Pg.1373]    [Pg.1539]    [Pg.2956]    [Pg.167]    [Pg.702]    [Pg.33]    [Pg.409]    [Pg.80]    [Pg.481]    [Pg.182]    [Pg.206]    [Pg.138]    [Pg.144]    [Pg.144]    [Pg.206]    [Pg.208]    [Pg.211]    [Pg.133]    [Pg.627]    [Pg.114]    [Pg.204]    [Pg.6]    [Pg.101]    [Pg.102]    [Pg.114]    [Pg.147]    [Pg.237]    [Pg.256]    [Pg.515]    [Pg.27]   
See also in sourсe #XX -- [ Pg.27 , Pg.73 , Pg.80 , Pg.118 , Pg.154 , Pg.165 , Pg.281 , Pg.282 , Pg.283 , Pg.296 , Pg.297 , Pg.299 , Pg.301 , Pg.302 , Pg.304 , Pg.305 , Pg.372 , Pg.373 , Pg.374 , Pg.375 , Pg.383 , Pg.386 , Pg.387 , Pg.393 ]




SEARCH



Absolute Integrated Intensities

Absolute integrated intensities of »

Absorption intensity, apparent integrated

Apparent integrated intensity

Integral band intensities

Integral formulation Intensity

Integral intensities of the

Integral intensity

Integrated Intensity as a Function of Annealing Time

Integrated absorption intensities

Integrated absorption intensities General

Integrated absorption intensities definition

Integrated absorption intensities equation

Integrated absorption intensities measurement

Integrated intensity

Integrated intensity

Integrated intensity of the infrared

Integrated intensity of the infrared absorption band

Integrated intensity ratio

Integrated intensity values

Integrated peak intensity

Integrated scattering profile intensity

Light scattering integrated intensity

Orientation-dependent time-integrated intensity

Prediction of Integrals and Intensities

Profile fitting parameters integrated intensity

Spectra) integrated intensities, band shapes

True integrated intensity

© 2024 chempedia.info