Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Integrator cables

Flexible, Micromachined Neural Prostheses with Integrated Cables 146... [Pg.132]

Fig.19. Sieve with integrated cables (length 21 mm) and connection pads (light micrograph)... Fig.19. Sieve with integrated cables (length 21 mm) and connection pads (light micrograph)...
Have fire-alarm circuit integrity cable in accordance with NFPA 70. [Pg.605]

BS7917 Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed off-shore units. Requirements and test methods. [Pg.529]

Stieglitz, T. Beutel, H. and Meyer, J.-U. A flexible, light-weight multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves. Sensors and Actuators A 60 (1997), pp. 240-243... [Pg.504]

Electrical Concerns Electrical requirements for installing two- to four-gas chromatographs are similar to those for a single-gas chromatograph. Each instrument should be on its own 15-20-A circuit. Try to keep related electrical devices (integrators, computers, etc.), except electrically acmated devices, on the same circuit. Detector and integrator cables need to be shielded and located 6 in. or more away from the electrical lines. The gas lines, particularly copper lines, should be 6-12 in. (15-30 cm) away from the power lines—they can pick up electrical current if they are too close to the power hues. [Pg.537]

Figure 13.26 Sleds with six cast iron anodes, integrated cable, and protective hose for an operation capacity of 75 amperes for fifteen years. (Courtesy of Dean Rookes, West Coast Corrosion Prevention Ltd.)... Figure 13.26 Sleds with six cast iron anodes, integrated cable, and protective hose for an operation capacity of 75 amperes for fifteen years. (Courtesy of Dean Rookes, West Coast Corrosion Prevention Ltd.)...
In addition to the controlling computer the system contains only a small control unit - PSP-4 (weight approx. 5 kg.) which among other system components includes a motor control system integrated closely with the PS-4 ultrasonic system. For communication between the PSP-4 control unit and the robot as well as robot power supply is used a single cable less than 10 mm. in diameter. [Pg.870]

Failures of impressed-current systems may occur not because of anode failure in a specific environment but because of poor integrity of the anode/cable connection or the use of an inferior cable insulation. Particular... [Pg.163]

It is necessary to ensure the integrity of anode cable connections and to give consideration to the number of such connections related to longitudinal resistance of the anode and current attenuation, if early failure is to be avoided. [Pg.174]

D 2770 Ozone-Resist Ethylene-Propylene Rubber Integral Insulation Jacket for Wire Cable. [Pg.223]

SC Esener, D Hartmann, MJ Heller, JM Cable. DNA-assisted micro-assembly a heterogeneous integration technology for optoelectronics. Proc. SPIE Critical Reviews of Optical Science and Technology, Heterogeneous Integration, San Jose, CA, 1998, pp 65-68. [Pg.427]

Physically, the MIMOS II Mossbauer spectrometer has two components that are joined by an interconnect cable the sensor head (SH) and electronics printed-circuit board (PCB). On MER, the SH is located at the end of the Instrument Deployment Device (IDD) and the electronics board is located in an electronics box inside the rover body. On Mars-Express Beagle-2, a European Space Agency (ESA) mission in 2003, the SH was mounted also on a robotic arm integrated to the Position... [Pg.54]

Fig. 2 Cable suspended sediment samplers in operation at MEMS (Fig. 1), lower Ebro, during floods (a) US DH-74 depth-integrating suspended sediment sampler (b) US DH-59 depth-integrating suspended sediment sampler (c) 152 mm intake Helley-Smith sampler (d) 76 mm intake Helley-Smith sampler. See text and [25] and [31] for operational details... Fig. 2 Cable suspended sediment samplers in operation at MEMS (Fig. 1), lower Ebro, during floods (a) US DH-74 depth-integrating suspended sediment sampler (b) US DH-59 depth-integrating suspended sediment sampler (c) 152 mm intake Helley-Smith sampler (d) 76 mm intake Helley-Smith sampler. See text and [25] and [31] for operational details...
Process Facilities 15 Area electrical classification 16 Accessibility for mechanical integrity (sampling, maintenance, repairs) 17 Protection of piping and vessels from vehicles and forklifts 18 Protection of small-bore lines, fittings from external impact, personnel 19 Routing of process piping, critical controls cable trays, critical utilities 20 Vent, drain, and relief valve discharge locations... [Pg.31]

Integration, thanks to the plastic elements, of the maximum number of functionalities mountings, fastening points, fixings, cable holders, housings, embossings, eyelets, clips, etc. [Pg.752]


See other pages where Integrator cables is mentioned: [Pg.169]    [Pg.144]    [Pg.228]    [Pg.169]    [Pg.144]    [Pg.228]    [Pg.784]    [Pg.135]    [Pg.533]    [Pg.329]    [Pg.351]    [Pg.127]    [Pg.505]    [Pg.332]    [Pg.258]    [Pg.30]    [Pg.350]    [Pg.351]    [Pg.353]    [Pg.374]    [Pg.12]    [Pg.857]    [Pg.29]    [Pg.256]    [Pg.257]    [Pg.262]    [Pg.263]    [Pg.241]    [Pg.134]    [Pg.459]    [Pg.19]    [Pg.62]    [Pg.12]    [Pg.359]   
See also in sourсe #XX -- [ Pg.537 ]




SEARCH



Cables

© 2024 chempedia.info