Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Quantification integration

CIDIQ Confocal image-assisted 3-dimensionally integrated quantification... [Pg.1527]

Computer-aided drug design (CADD) 1607 Comvax 18 Concanavalin A 484 Confocal image assisted 3-dimensionally integrated quantification (CIDIQ) 1526 Congestive heart failure (CHF) 318 Congo Red 1287... [Pg.1849]

Parameters of measurement, integration, quantification and further evaluation, scanner type, principle of measurement, software version, etc. [Pg.227]

Integration of the peaks for the two diastereomers accurately quantifies the relative amounts of each enantiomer within the mixture. Such diastereometic derivatives may also be analy2ed by more accurate methods such as gc or hplc. One drawback to diastereometic detivatization is that it requites at least 15 mg of material, which is likely to be material painstakingly synthesized, isolated, and purified. The use of analytical chiral chromatographic methods allows for the direct quantification of enantiomeric purity, is highly accurate to above 99.8% ee, and requites less than one milligram of material. [Pg.250]

In any given situation, there may be different levels of dependence between an operator s performance on one task and on another because of the characteristics of the tasks theraseb e.s. or because of the manner in which the operator was cued to perform the tasks. Dependence levels between the performances of two (or more) operators also may differ. The analyses should account for dependency in human-error probabilities. In addition, each sequence may have a set of human recovery actions that if successfully performed will terminate or reduce the consequences of the sequence. This information, coupled with a knowledge of the system success criteria leads to the development of human success and failure probabilities which are input to the quantification of the fault iices or event trees. With this last step, the HRA is integrated into the PSA, and Pl. ise 4 is complete. [Pg.175]

In addition, the chapter will provide an overview of htunan reliability quantification techniques, and the relationship between these techniques and qualitative modeling. The chapter will also describe how human reliability is integrated into chemical process quantitative risk assessment (CPQRA). Both qualitative and quantitative techniques will be integrated within a framework called SPEAR (System for Predictive Error Analysis and Reduction). [Pg.202]

INTEGRATION WITH HARDWARE ANALYSIS. The error probabilities obtained from the quantification procedure are incorporated in the overall system fault trees and event trees. [Pg.229]

Crane, C.J. and Carr, S.H. 1994 The integration and quantification of economic data from a late Preclassic Maya community in Belize. In Sobolik, K.D., ed., Paleonutrition The Diet and Health of Prehistoric Americans. Occasional Paper 22, Center for Archaeological Investigations, Carbondale, University of Southern Illinois 66-79. [Pg.36]

On-line SFE-SFC has also been used for the quantification of erucamide and antioxidants in PE [110]. Cotton et al. [15] have reported quantitative extraction of additives from PP at five different extraction pressures, at a constant flow-rate and temperature. Below 50 atm, extraction was negligible between 50 and 200 atm, Tin-uvin 326 and 770 were extracted, along with small quantities of oligomers. Higher pressures lead to the extraction of all the additives present, with the integrated peak areas conforming well to the actual concentrations. [Pg.444]

In some cases it makes sense to record a signal not only in its original form but also in its integrated form or in the form of its first, second or higher derivation. In this way, the quantification of signal intensity can be improved and the position of the signal can be measured more precisely, respectively. [Pg.72]

As you are no doubt aware, integrals are one of the key parameters in the interpretation of proton spectra and are pivotal in quantification. They measure the area under a peak and this is directly proportional to the number of protons (in the case of proton NMR) in that environment. Most software will automatically try to identify the peaks in your spectrum and integrate them for you. If you need to do it yourself, then it is a fairly trivial matter of defining the start and end point of the integrals of interest. The only complication is that you may need to tweak the slope and bias of the integral. This should be unnecessary if you have got the phase and baseline of your spectrum correct. If you find that you need to adjust slope and bias, we suggest that you go back and try to sort out baseline and phase a bit better. [Pg.39]

FIGURE 6.3 Quantification on the first half of an isolated peak. The spectrum is from the [2Fe-2S] cluster in the enzyme adenosine phosphosulfate reductase from Desulfovibrio vulgaris (Verhagen et al. 1993). The inset shows the asymmetrical low-field -feature the vertical line at the peak position indicates the rightmost integration limit for quantification on half... [Pg.101]

Figure 2 shows the hydrogen to consumed propane ratio and methane formed (as integrated area, no quantification was possible) vs. the number of pulses injected. It can be seen that significant amounts of methane are formed right from the first pulse injected. [Pg.403]

In order to study simultaneously the behaviour of parent priority surfactants and their degradation products, it is essential to have accurate and sensitive analytical methods that enable the determination of the low concentrations generally occurring in the aquatic environment. As a result of an exhaustive review of the analytical methods used for the quantification within the framework of the three-year research project Priority surfactants and their toxic metabolites in wastewater effluents An integrated study (PRISTINE), it is concluded that the most appropriate procedure for this purpose is high-performance (HP) LC in reversed phase (RP), associated with preliminary techniques of concentration and purification by solid phase extraction (SPE). However, the complex mixtures of metabolites and a lack of reference standards currently limit the applicability of HPLC with UV- or fluorescence (FL-) detection methods. [Pg.25]


See other pages where Quantification integration is mentioned: [Pg.202]    [Pg.112]    [Pg.453]    [Pg.53]    [Pg.1526]    [Pg.367]    [Pg.6]    [Pg.202]    [Pg.112]    [Pg.453]    [Pg.53]    [Pg.1526]    [Pg.367]    [Pg.6]    [Pg.419]    [Pg.398]    [Pg.145]    [Pg.139]    [Pg.65]    [Pg.569]    [Pg.559]    [Pg.416]    [Pg.423]    [Pg.330]    [Pg.740]    [Pg.46]    [Pg.157]    [Pg.259]    [Pg.347]    [Pg.100]    [Pg.272]    [Pg.535]    [Pg.85]    [Pg.85]    [Pg.86]    [Pg.197]    [Pg.234]    [Pg.385]    [Pg.390]    [Pg.17]    [Pg.74]   
See also in sourсe #XX -- [ Pg.161 ]




SEARCH



Quantification integration methods

© 2024 chempedia.info