Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Instructions direct measurement

It is apparent that CMC values can be expressed in a variety of different concentration units. The measured value of cCMC and hence of AG c for a particular system depends on the units chosen, so some uniformity must be established. The issue is ultimately a question of defining the standard state to which the superscript on AG C refers. When mole fractions are used for concentrations, AG c directly measures the free energy difference per mole between surfactant molecules in micelles and in water. To see how this comes about, it is instructive to examine Reaction (A) —this focuses attention on the surfactant and ignores bound counterions — from the point of view of a phase equilibrium. The thermodynamic criterion for a phase equilibrium is that the chemical potential of the surfactant (subscript 5) be the same in the micelle (superscript mic) and in water (superscript W) n = n. In general, pt, = + RTIn ah in which... [Pg.372]

It is instructive to make a quantitative comparison between the experimental and theoretical curves. The light scattering intensity, expressed as the Rayleigh ratio, is a function of the size and number of particles. If all three reactions shown in Figure 7 polymerize at the same rate, Rp, then at a given time, say 10 seconds, the total volume of polymer formed, VT, will be the same in all three. Under these conditions, the scattering intensity becomes a direct measure of the relative number of particles ... [Pg.26]

A totally different method for defining quantities is the direct metricization of a concept or characteristic. A concept, initially only understood qualitatively, is then quantified by specifying an appropriate instruction for measurement. This is the usual procedure for quantities considered basic concepts (length, duration, mass. [Pg.11]

Although some countries legislation does not recognize the term acceptable risk (which is seen as an imperfection), on many occasions the term residual hazard is used, supplemented by directives that instruct on measures for the elimination and reduction of the hazard. In practical life, it is possible to eliminate the hazard (risk) only in a limited number of specific cases (e.g. cranes excluded from the technological cycle, load oscillation eliminated by fixed suspension). From a practical point of view, it is useful to apply reduction or minimization of hazards (risk) and the final value of the reduction or minimization must be defined by acceptable hazard (risk). The level of the risk is determined by the equipment (travelling crane) user based on the levels of risk he wishes to achieve. [Pg.94]

Proportional detectors measure the process condition, which can then he compared hy the controller with the required value. They are not direct acting, and need a controller to convert the signal to a working instruction to the controlled device. Proportional detectors include ... [Pg.326]

The form of the Plmn will be discussed later, because it is instructive to develop the argument by considering next the information which is obtained from any spectroscopic technique. Figure 2a shows a direction within a unit of structure which is defined by the polar and azimuthal angles (, r ). For example, this could be the direction defining the change in dipole moment (the transition moment vector) in an infra-red spectroscopic measurement. The spectroscopic measurements provide... [Pg.84]

Patients with incomplete responses should contact their health care provider immediately for instructions, while those with a poor response should proceed directly to the emergency department.1 In the emergency department, baseline PEF measurements and oxygen saturation should be monitored. PEF should be monitored before and 15 to 20 minutes after bronchodilator administration. Treatment should be initiated as soon as lung function is assessed (Fig. 11-3). Dosages for emergency department and hospital use of quick relief medications are shown in Table 11-5. [Pg.225]

Where there is a dosing device provided with the product, the dose reproducibility and accuracy should be demonstrated. Examples include dropper devices, dose-measuring devices, and pen injectors. The instructions for use should also be discussed for such devices and may be particularly important for devices such as two-chamber cartridges and the like containing suspension products. It might be necessary to discuss how dosing devices meet the relevant Essential Requirements of the Medical Device Directives with reference to appropriate and relevant harmonized and other European (EN) and International Standards Organization (ISO) standards. [Pg.657]

There are several reasons why the sum of squares, i.e. the sum of squared differences between the measured and modelled data, is used to define the quality of a fit and thus is minimised as a function of the parameters. It is instructive to consider alternatives to the sum of squares, (a) Minimal sum of differences - is not an option, as positive and negative differences cancel each other out. Huge deviations in both directions can result in zero sums. [Pg.102]

With this background infonnation on the inverse methods, it is instructive to examine the calculations for the inverse model in more detail. In Equation 5-23, the key to the model-building step is the inversion of the matrix CR ). This is a squire matrix with number of rows and columns equal to the number of measurement variables (nvars). From theory, a number of independent samples in the calibration set greater than or equal to nvars is needed in order to invert this matrix. For most analytical measurement systems, nvars (e.g., number of wavelengths) is greater than the number of independent samples and therefore RTr cannot be directly inverted. However, with a transformation, calculating she pseudo-inverse of R (R is possible. How this transformation is accomplished distinguishes the different inverse methods. [Pg.130]

We have chosen to express our results as permeances rather than permeabilities because we are presently unable to justify the assumption that the properties of the material are uniform throughout the film. We suspect that normalizing the results to unit thickness would introduce additional scatter. The SRM certificate gives instructions for calculating gas transmission rates, which are the quantities that are measured directly. [Pg.93]

An expert system is a computer program that uses an expert s knowledge in a particular domain to solve a narrowly focused, complex problem. An offline system uses information entered manually and produces results in visual form to guide the user in solving the problem at hand. An online system uses information taken directly from process measurements to perform tasks automatically or instruct or alert operating personnel to the status of the plant. [Pg.26]

Figure 19.11 Comparison of anomalous signals obtained for Rb-RNA and Rb-DNA. Panel (A) shows the ASAXS signals for both DNA and RNA displayed on a log scale. Panels (B) and (C) illustrate an alternative method for comparing measured with predicted ion distributions. A radial Patterson inversion can be applied both to the data and to the curve generated from simulation. Although it is challenging to interpret this curve directly (see text), it is instructive to compare experiment with prediction in this form. When an ion probe radius of 3 A is used, the differences in ion distribution between RNA and DNA are clearly mirrored by simulation. Figure 19.11 Comparison of anomalous signals obtained for Rb-RNA and Rb-DNA. Panel (A) shows the ASAXS signals for both DNA and RNA displayed on a log scale. Panels (B) and (C) illustrate an alternative method for comparing measured with predicted ion distributions. A radial Patterson inversion can be applied both to the data and to the curve generated from simulation. Although it is challenging to interpret this curve directly (see text), it is instructive to compare experiment with prediction in this form. When an ion probe radius of 3 A is used, the differences in ion distribution between RNA and DNA are clearly mirrored by simulation.

See other pages where Instructions direct measurement is mentioned: [Pg.478]    [Pg.550]    [Pg.109]    [Pg.158]    [Pg.26]    [Pg.424]    [Pg.425]    [Pg.426]    [Pg.53]    [Pg.423]    [Pg.53]    [Pg.164]    [Pg.483]    [Pg.610]    [Pg.528]    [Pg.609]    [Pg.162]    [Pg.335]    [Pg.156]    [Pg.46]    [Pg.295]    [Pg.146]    [Pg.3]    [Pg.194]    [Pg.15]    [Pg.53]    [Pg.64]    [Pg.30]    [Pg.50]    [Pg.93]    [Pg.77]    [Pg.34]    [Pg.387]    [Pg.163]    [Pg.258]    [Pg.52]    [Pg.56]    [Pg.315]   
See also in sourсe #XX -- [ Pg.88 , Pg.162 , Pg.284 ]




SEARCH



Direct measure

Direct measurement

Directly measured

Instructions

© 2024 chempedia.info