Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Injection, defined

Figure 2 shows a schematic diagram of a pressure let down system, which conforms to the European Standard ISO 6978 (ASTM 6350) for natural gas sampling. By careful choice of components and temperature of operation it is possible to provide reliable data on the mercury levels present in the natural gas samples. By injecting defined samples of mercury into the sample line prior to the sample collection, it is possible to check the validity of the measurements by testing the spike recovery. Recoveries in the region of 95-105 % will show that there is little, if any, loss with the system, and the analyst can be confident of the levels found in the gas streams. [Pg.210]

The point of injection defines the distance from the injector outlet to the mixer face (also called the decomposition portion). The distance from the outlet of the mixer to the face of the substrate is called the mixing pipe. Both of these dimensions, as well as the injector mount geometry chosen, has to be evaluated based on the available packaging space for the given application. [Pg.476]

If one imagine.s that the fuel is used in the liquid state in the form of droplets —as in the case of fuel injection— the specific energy of the motor fuel (SE) is expressed in kilojoules per kilogram of air utilized, under predetermined conditions of equivalence ratio (stoichiometry for example). The SE is none other than the NHY /r quotient where r represents the previously defined stoichiometric ratio. [Pg.186]

It Is important to know how much each well produces or injects in order to identify productivity or injectivity changes in the wells, the cause of which may then be investigated. Also, for reservoir management purposes (Section 14.0) it is necessary to understand the distribution of volumes of fluids produced from and injected into the field. This data is input to the reservoir simulation model, and is used to check whether the actual performance agrees with the prediction, and to update the historical data in the model. Where actual and predicted results do not agree, an explanation is sought, and may lead to an adjustment of the model (e.g. re-defining pressure boundaries, or volumes of fluid in place). [Pg.221]

There are otlier teclmiques for mass separation such as tire quadmpole mass filter and Wien filter. Anotlier mass spectrometry teclmique is based on ion chromatography, which is also capable of measuring tire shapes of clusters [30, 31]. In tills metliod, cluster ions of a given mass are injected into a drift tube witli well-defined entrance and exit slits and filled witli an inert gas. The clusters drift tlirough tills tube under a weak electric potential. Since the... [Pg.2390]

CD-ROM disks are nearly identical to the weU-known compact disk-digital audio (CD-DA short CD). The information on a CD-ROM is stamped in the form of clearly defined pits on the disk surface during the disk s manufacture, using injection mol ding or injection stamping techniques. A metal stamper transfers the digital information to the disk s surface. [Pg.138]

Because of the large number of samples and repetitive nature of environmental analysis, automation is very important. Autosamplers are used for sample injection with gc and Ic systems, and data analysis is often handled automatically by user-defined macros in the data system. The high demand for the analysis of environmental samples has led to the estabUshment of contract laboratories which are supported purely by profits from the analysis. On-site monitoring of pollutants is also possible using small quadmpole ms systems fitted into mobile laboratories. [Pg.548]

Wettabihty is defined as the tendency of one fluid to spread on or adhere to a soHd surface (rock) in the presence of other immiscible fluids (5). As many as 50% of all sandstone reservoirs and 80% of all carbonate reservoirs are oil-wet (10). Strongly water-wet reservoirs are quite rare (11). Rock wettabihty can affect fluid injection rates, flow patterns of fluids within the reservoir, and oil displacement efficiency (11). Rock wettabihty can strongly affect its relative permeabihty to water and oil (5,12). When rock is water-wet, water occupies most of the small flow channels and is in contact with most of the rock surfaces as a film. Cmde oil does the same in oil-wet rock. Alteration of rock wettabihty by adsorption of polar materials, such as surfactants and corrosion inhibitors, or by the deposition of polar cmde oil components (13), can strongly alter the behavior of the rock (12). [Pg.188]

Cartiers can also be generated in a semiconductor by the absorption of light or injected into the semiconductor from ap—n or Schottky junction. In either case, as soon as the source is removed the density of those excess carriers begins to decrease exponentially with time. The time it takes for the density to be reduced to 1/ of the original value is defined as the carrier lifetime, T. For siUcon, T is typically in the microsecond range. [Pg.531]

Experimental techniques to visualize flows have been extensively used to define fluid flow in pipes and air flow over lift and control surface of airplanes. More recently this technology has been appHed to the coating process and it is now possible to visualize the flow patterns (16,17). The dimensions of the flow field are small, and the flow patterns both along the flow and inside the flow are important. Specialized techniques such as utilizing small hydrogen bubbles, dye injection, and optional sectioning, are required to visualize these flows. [Pg.313]

The definition of a drug differs between dictionaries and among the various professional specialisms. A search of the internet elicited various definitions and a paraphrase of the most memorable is a compound can be defined as a drug if, when injected into a rodent, it yields a scientific publication . Although this is a memorable definition, for the purposes of this review, however, a drug is defined broadly as a compound that has properties that influence the health of an animal when ingested or administered to that animal. A brief look at current literature will quickly convince the reader that this is a definition which covers man-made and natural compounds that can be extracted from plant material and microbes and iised. ... [Pg.85]

Fig. 3-3. Comparison of the values of enantiomeric resolution of different DNP-D,L-amino acids at different deconvolution stages of a cyclic hexapeptide sublibrary. Resolution values in a cyclo(Arg-Lys-X-X-X-P-Ala) sublibrary, in the first line, are compared to those obtained in sublibraries with a progressively increasing number of defined positions. All the sublibraries were 30 mM in the running buffer while the completely defined cyclo(Arg-Lys-Tyr-P-Tyr-P-Ala) peptide is used at 10 mM concentration. Conditions cyclopeptide sublibrary in 20 mM sodium phosphate buffer, pH 7.0 capillary, 50 pm i.d., 65 cm total length, 57 cm to the window V = -20 kV, I = 40 electrokinetic injection, -10 kV, 3 s detection at 340 nm. (Reprinted with permission from ref. [75]. Copyright 1998, American Chemical Society.)... Fig. 3-3. Comparison of the values of enantiomeric resolution of different DNP-D,L-amino acids at different deconvolution stages of a cyclic hexapeptide sublibrary. Resolution values in a cyclo(Arg-Lys-X-X-X-P-Ala) sublibrary, in the first line, are compared to those obtained in sublibraries with a progressively increasing number of defined positions. All the sublibraries were 30 mM in the running buffer while the completely defined cyclo(Arg-Lys-Tyr-P-Tyr-P-Ala) peptide is used at 10 mM concentration. Conditions cyclopeptide sublibrary in 20 mM sodium phosphate buffer, pH 7.0 capillary, 50 pm i.d., 65 cm total length, 57 cm to the window V = -20 kV, I = 40 electrokinetic injection, -10 kV, 3 s detection at 340 nm. (Reprinted with permission from ref. [75]. Copyright 1998, American Chemical Society.)...
This chapter provided several cost recommendations that, once implemented, would provide cost-effective added value to the operation of the FCC. Examples of such items include tips on debottlenecking the air blower, wet gas compressor, and catalyst circulation. This chapter also discussed the latest technologies regarding the riser termination devices, as well as feed injection systems. Prior to implementing any new technologies, it is critical that the objectives and the limitations of the unit are clearly defined to ensure the expected benefits of the new technology are realized. [Pg.306]


See other pages where Injection, defined is mentioned: [Pg.242]    [Pg.114]    [Pg.94]    [Pg.31]    [Pg.346]    [Pg.242]    [Pg.114]    [Pg.94]    [Pg.31]    [Pg.346]    [Pg.1058]    [Pg.650]    [Pg.172]    [Pg.185]    [Pg.50]    [Pg.51]    [Pg.52]    [Pg.206]    [Pg.530]    [Pg.171]    [Pg.211]    [Pg.136]    [Pg.512]    [Pg.350]    [Pg.377]    [Pg.523]    [Pg.483]    [Pg.1533]    [Pg.218]    [Pg.54]    [Pg.29]    [Pg.232]    [Pg.506]    [Pg.751]    [Pg.431]    [Pg.402]    [Pg.227]    [Pg.243]    [Pg.180]    [Pg.182]    [Pg.548]    [Pg.195]   
See also in sourсe #XX -- [ Pg.109 ]




SEARCH



© 2024 chempedia.info