Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Initial placement

It can be shown that the BBM is capable of universal computation ([fredkin82, marg84, marg88]). Unfortunately, as shown by Zurek [zurek84], the model is also unlikely to ever be realized in practice. Because BBM computations all depend so critically on initial ball and mirror placement, the fact that any errors in the initial placement grow exponentially in time effectively renders their results either suspect or meaningless. [Pg.673]

If the initial placement of the coefficient 1 yields fractional coefficients in the equation, we can get integer values by simply multiplying every coefficient (including the coefficients equal to 1) by the smallest integer that will clear the fractions. [Pg.222]

An engineered water-soluble C4H (originally from Helianthus tuherosus) has been expressed and purified from yeast and used for H-NMR studies in order to investigate the active site and the substrate positioning. The initial placement of the cinnamate parallel to the heme was not able to explain the exclusive 4-hydroxylation of the substrate and it was suggested that the substrate has to shift during the catalytic cycle (Schoch et al, 2003). [Pg.186]

Subgingival placement of antibiotic fibers or strips Initial placement of orthodontic bands but not brackets Intraligamentary local anesthetic injections Prophylactic cleaning of teeth or implants where bleeding is anticipated... [Pg.2010]

Theoretical pKa calculations indicate that the first two histidine side chains to become protonated are His 140 and His 177. In a single 10 ns simulation, Langella et al. found little difference from a neutral pH simulation [99], as could be expected from their initial placement out into solvent. With all histidine side chains protonated, however, simulations revealed more significant changes [59]. In this mildly acidic pH environment, the 3io-helix conformation in res. 153-156 that was formed for 25% of the time at neutral pH largely disappeared. This is in agreement with the... [Pg.177]

Fig. 3.10 Inverted x-ray radiograph of the postweld position of a lead marker wire in the (a) plan view and (b) side view. Note the ° through-material thickness traces of the lead wire in the side view. The initial placement of the lead wire can be observed... Fig. 3.10 Inverted x-ray radiograph of the postweld position of a lead marker wire in the (a) plan view and (b) side view. Note the ° through-material thickness traces of the lead wire in the side view. The initial placement of the lead wire can be observed...
Figures 2-4 show many collectors that have large ebullition events. Some occur during the first 5 min of methane accumulation. While it is possible that this may have been caused by the initial placement of the collectors on the surface of the water (between 4 and 8 cm deep depth determined after the methane measurements were completed), there are many examples of ebullition that were not associated with the initial placement of the collectors. During the... Figures 2-4 show many collectors that have large ebullition events. Some occur during the first 5 min of methane accumulation. While it is possible that this may have been caused by the initial placement of the collectors on the surface of the water (between 4 and 8 cm deep depth determined after the methane measurements were completed), there are many examples of ebullition that were not associated with the initial placement of the collectors. During the...
The latency from initial placement in the start box until all four of the animal s paws were on the floor of the odor chamber was recorded for each animal. If an animal did not enter the second chamber after 2 min the trial was terminated. [Pg.510]

Such migration requires only partial miscibility in the polymer matrix, silicone in the particular case studied by Stein et al. Owen and co-workers [9] have suggested that solubility parameter calculations can be useful in designing suitable compositions with partial miscibility. These ideas appear superficially to be at odds with compatibility/penetration and interpenetrating network concepts. However, these contrary solubility requirements are a consequence of the initial placement of the adhesion promoter. When used as a primer, it is already placed at the interface so needs no partial solubility characteristic to drive it there, as is needed when it is initially dispersed throughout the polymer matrix. In both cases it is the development of a strengthening interfacial phase that accounts for the enhancement in adhesion that is sought by the user. [Pg.425]

Rgure 8.2 is a closeup view of the control console and main operator s panel as per current design specifications. The initial placement of the console itself, as well as the layout of the various dials, switches, gauges, and levers on the panel, as seen here, has been established on the basis of availability of panel space with minimal consideration of operator interface requirements. [Pg.98]

Burbank F, Forcier N (1997) Tissue marking clip for stereotactic breast biopsy initial placement accuracy, long term stability and usefulness as a guide for wire localization. Radiology 205 407-415... [Pg.107]

Placement of self-expanding metal stents does not require post deployment dilation since the stent usually achieves its intended (and inherent) diameter within the first 2448 h after initial placement. The constant radial forces allow slowbut steady extension of the stent in even firm stenoses. However, if the initial stent diameter, achieved immediately after placement, does not seem to be sufficient for adequate ventilation, additional balloon dilation can be carried out to achieve an appropriate diameter (see Fig. 12.1e). [Pg.260]

Deformation and migration of Palmaz stents in three patients brought the suitability of the stent for use in the tracheobronchial system into question (Perini et al. 1999). The authors encountered stent collapse in three patients at 44 days, 78 days and 362 days after initial placement, respectively. Three stents also showed signs of complete or partial migration. The authors decided to no longer use this stent type in the tracheobronchial tree. [Pg.267]

The purpose in requiring the examining physician to supply the employer with a written opinion is to provide the employer with a medical basis to aid in the determination of initial placement of employees and to assess the employee s ability to use protective clothing and equipment. [Pg.1153]

For the majority of developers of a new technology or system, and in particular those outside the mainstream of large corporations, a crucial element of the development plan becomes that of who will pay for itV With development capital in short supply and the venture capital (VC) market not necessarily willing to invest where there is a limited long-term potential for an initial placement offer (IPO) exit to the stock market and relatively low capital needs, the developer must be aware of the financial market... [Pg.30]

Still technique for treating rib somatic dysfunctions generally relates to the positional finding, anterior or posterior, of the involved rib. A simple relationship between an anterior rib and an inhalation dysfunction and a posterior rib and an exhalation dysfunction is drawn, which also contributes to the initial placement into the freedom of motion followed by engagement of the barriers. Some modification can also be included for pump or bucket handle components as well. [Pg.385]


See other pages where Initial placement is mentioned: [Pg.2305]    [Pg.425]    [Pg.681]    [Pg.274]    [Pg.194]    [Pg.247]    [Pg.675]    [Pg.315]    [Pg.126]    [Pg.312]    [Pg.384]    [Pg.293]    [Pg.295]    [Pg.296]    [Pg.301]    [Pg.118]    [Pg.2305]    [Pg.43]    [Pg.45]    [Pg.400]    [Pg.92]    [Pg.45]    [Pg.211]    [Pg.74]    [Pg.201]    [Pg.211]    [Pg.263]    [Pg.661]    [Pg.1265]    [Pg.57]    [Pg.496]    [Pg.123]    [Pg.259]   
See also in sourсe #XX -- [ Pg.170 ]




SEARCH



Initial placement offer

Placement

© 2024 chempedia.info