Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Infrared spectroscopy intensity

Alternation is usually above 90%. Nearly perfect alternation of isomeric units in a ca 1 1 monomer ratio has been confirmed by infrared spectroscopy. Bands at 733 and 721 cm have an intensity proportional to the concentration of (CH2) groups (n = 4 and <6, respectively) present in a copolymer containing 46 mol % tetrafluoroethylene intensity decreases with increasing concentration of fluorinated monomer. [Pg.366]

If i = i — ik] and H2 = ns — are known as a function of wavelength, Eq. 12 can be used to calculate the entire RAIR spectrum of a surface film. Since transmission infrared spectroscopy mostly measures k, differences between transmission and RAIR spectra can be identified. Fig. 6 shows a spectrum that was synthesized assuming two Lorentzian-shaped absorption bands of the same intensity but separated by 25 cm. The corresponding spectrum of i values was calculated from the k spectrum using the Kramers-Kronig transformation and is also shown in Fig. 6. The RAIR spectrum was calculated from the ti and k spectra using Eqs. 11 and 12 and is shown in Fig. 7. [Pg.251]

The structure of the protonated enamines has been investigated by infrared spectroscopy. On protonation there is a characteristic shift of the band in the double-bond stretching region to higher frequencies by 20 to 50 cm with an increased intensity of absorption (6,13,14a). Protonated enamines also show absorption in the ultraviolet at 220-225 m/x due to the iminium structure (14b). This confirms structure 5 for these protonated enamines, because a compound having structure 4 would be expected to have only end absorption as the electrons on nitrogen would not be available for interaction with the n electrons of the double bond. [Pg.117]

Plutonium(IV) polymer has been examined by infrared spectroscopy (26). One of the prominent features in the infrared spectrum of the polymer is an intense band in the OH stretching region at 3400 cm 1. Upon deuteration, this band shifts to 2400 cm 1. However, it could not be positively assigned to OH vibrations in the polymer due to absorption of water by the KBr pellet. In view of the broad band observed in this same region for I, it now seems likely that the bands observed previously for Pu(IV) polymer are actually due to OH in the polymer. Indeed, we have observed a similar shift in the sharp absorption of U(0H)2S0ir upon deuteration (28). This absorption shifts from 3500 cm 1 to 2600 cm 1. [Pg.63]

The first Raman and infrared studies on orthorhombic sulfur date back to the 1930s. The older literature has been reviewed before [78, 92-94]. Only after the normal coordinate treatment of the Sg molecule by Scott et al. [78] was it possible to improve the earlier assignments, especially of the lattice vibrations and crystal components of the intramolecular vibrations. In addition, two technical achievements stimulated the efforts in vibrational spectroscopy since late 1960s the invention of the laser as an intense monochromatic light source for Raman spectroscopy and the development of Fourier transform interferometry in infrared spectroscopy. Both techniques allowed to record vibrational spectra of higher resolution and to detect bands of lower intensity. [Pg.47]

If gaseous S2O-SO2 mixtures are dissolved in dry solvents such as CS2, CCI4, CHCI3, CH2CI2, and liquid SO2 at temperatures between -75 and -1-25 °C, intense yellow solutions of polysulfuroxides are obtained which have been characterized only very poorly [19]. In contrast to the opinion of some authors [20], S2O cannot be detected in such solutions, e.g., by infrared spectroscopy. Most probably, mixtures of cyclic polysulfuroxides are present besides SO2 (see below, in particular the preparation of S5O), e.g. ... [Pg.207]

Novotny et al. [41] used p-polarized reflection and modulated polarization infrared spectroscopy to examine the conformation of 1 -1,000 nm thick liquid polyperfluoropropy-lene oxide (PPFPO) on various solid surfaces, such as gold, silver, and silica surfaces. They found that the peak frequencies and relative intensities in the vibration spectra from thin polymer films were different from those from the bulk, suggesting that the molecular arrangement in the polymer hlms deviated from the bulk conformation. A two-layer model has been proposed where the hlms are composed of interfacial and bulk layers. The interfacial layer, with a thickness of 1-2 monolayers, has the molecular chains preferentially extended along the surface while the second layer above exhibits a normal bulk polymer conformation. [Pg.226]

The specific surface area of the fresh and used catalysts was measured by nitrogen adsorption method (Sorptometer 1900, Carlo Erba Instruments). The catalysts were outgassed at 473 K prior to the measurements and the Dubinin equation was used to calculate the specific surface area. The acidity of investigated samples was measured by infrared spectroscopy (ATI Mattson FTIR) by using pyridine (>99.5%, a.r.) as a probe molecule for qualitative and quantitative determination of both Bronstcd and Lewis acid sites (further denoted as BAS and LAS). The amounts of BAS and LAS were calculated from the intensities of corresponding spectral bands by using the molar extinction coefficients reported by Emeis (23). Full details of the acidity measurements are provided elsewhere (22). [Pg.281]

The carbonyl index is not a standard technique, but is a widely used convenient measurement for comparing the relative extent and rate of oxidation in series of related polymer samples. The carbonyl index is determined using mid-infrared spectroscopy. The method is based on determining the absorbance ratio of a carbonyl (vC = 0) band generated as a consequence of oxidation normalised normally to the intensity of an absorption band in the polymer spectrum that is invariant with respect to polymer oxidation. (In an analogous manner, a hydroxyl index may be determined from a determination of the absorbance intensity of a vOH band normalised against an absorbance band that is invariant to the extent of oxidation.) In the text following, two examples of multi-technique studies of polymer oxidation will be discussed briefly each includes a measure of a carbonyl index. [Pg.394]

Figure 7 Hydroperoxide index (HI) determined from mid-infrared spectroscopy (ratio of the integrated intensity of the 3,552 cm 1 band to the integrated intensity of the band at 2,010 cm-1) as a function of total hydroperoxide content measured by iodiometric titration. Figure 7 Hydroperoxide index (HI) determined from mid-infrared spectroscopy (ratio of the integrated intensity of the 3,552 cm 1 band to the integrated intensity of the band at 2,010 cm-1) as a function of total hydroperoxide content measured by iodiometric titration.
For a ToF-SIMS investigation of the surface oxidative degradation of low-density polyethylene (LDPE), the polymer was exposed to 1802 rather than 1602 in order to be able to readily discriminate oxygen introduced by the ageing process from that in the polymer prior to ageing [102], Figure 36 shows an example series of ToF-SIMS spectra from this investigation, which shows the clear separation of the lsO species from the lsO species. In the study, close correlation was observed between the intensity of the lsO carbonyl species determined by mid-infrared spectroscopy with the ToF-SIMS 180- peak intensity as a function of 1802 exposure time. ToF-SIMS spectra obtained from microtomed cross-sections showed no... [Pg.435]

Finally, it should be kept in mind that quantification is often problematic in surface analysis and characterization. Firstly because some techniques are not really suited for quantification, but also in cases such as infrared spectroscopy where one does not really know precisely how deep into the material one is probing. Although, there are many good examples of semi-quantitative applications that involve measuring relative band intensities that relate to changes in a surface property. However, for problem solving revealing qualitative differences is often sufficient information to be able to identify cause and move on to look for a potential solution. [Pg.677]

Two polymorphs of (/q-penicillaminc are known [2], with the existence of these being confirmed using infrared spectroscopy and X-ray crystallography. It was reported that Form I has a minimum between its IR peaks at 1078 and 1101 cm-1 that are less intense than the adjacent peaks at about 1050 and 1160 cm-1, while Form II has an absorption peak at 1092 cm-1 which is more intense than the adjacent peaks at about 1050 and 10160 cm 1 [2],... [Pg.121]

Generalized Two-Dimensional (2D) correlation analysis is a powerful tool applicable to data obtained from a very broad range of measurements, such as chromatography or infrared spectroscopy. Relationships among systematic variations in infrared spectra are obtained as a function of spectroscopic frequencies. In this paper, the variation is induced by the introduction of small doses of CO in the catalytic cell, inducing a pressure change and a modification of adsorbed CO concentration. The correlation intensities are displayed in the form of 2D maps, usually referred to as 2D correlation spectra. 2D correlation analysis can help us to solve the complexity of the spectra... [Pg.59]

D correlation analysis is a powerful tool applicable to the examination of data obtained from infrared spectroscopy. The correlation intensities, displayed in the form of 2D maps, allow us to correlate the shift induced by CO adsorption and acidity of sites in dealuminated zeolites. Results are in accordance with previous results, obtained using only IR measurements, proving the validity of this technique. New correlations allowed the assignment of very complex groups of bands, and 2D correlation revealed itself as a great help for understanding acidity in dealuminated zeolites. 2D correlation has allowed us to validate the model obtained by NMR. [Pg.64]


See other pages where Infrared spectroscopy intensity is mentioned: [Pg.158]    [Pg.86]    [Pg.416]    [Pg.417]    [Pg.421]    [Pg.444]    [Pg.446]    [Pg.555]    [Pg.259]    [Pg.254]    [Pg.300]    [Pg.373]    [Pg.300]    [Pg.30]    [Pg.82]    [Pg.189]    [Pg.194]    [Pg.102]    [Pg.505]    [Pg.194]    [Pg.445]    [Pg.347]    [Pg.243]    [Pg.243]    [Pg.244]    [Pg.59]    [Pg.401]    [Pg.402]    [Pg.721]    [Pg.128]    [Pg.10]    [Pg.123]    [Pg.262]    [Pg.371]    [Pg.151]    [Pg.79]   
See also in sourсe #XX -- [ Pg.617 , Pg.618 ]




SEARCH



Infrared intensity

Intense infrared

Spectroscopy intensities

© 2024 chempedia.info