Inductively coupled plasma interferences

Gold is a useflil caUbration standard for this method (see Radioactive tracers). Whereas similar sensitivities can be achieved by inductively coupled plasma mass spectrometry (qv), the latter requires more extensive sample preparation to overcome interference by other metals such as copper (64). [Pg.381]

Bjorn E, Freeh W, Hoffmann E, Liidke C (1998) Investigation and quantification of spectroscopic interferences from polyatomic species in inductively coupled plasma mass spectrometry using electrothermal vaporization or pneumatic nebulization for sample introduction. Spectrochim Acta 53B 1766... [Pg.237]

At present, inductively coupled plasma mass spectrometry provides a unique, powerful alternative for the determination of rare earths in natural samples [638,639]. Nevertheless, its application to the determination of rare earths at ultratrace concentration level in seawater is limited, because highly saline samples can cause both spectral interferences and matrix effects [640]. Therefore, a separation of the matrix components and preconcentration of the analytes are prerequisites. To achieve this goal, many preconcentration techniques have been used, including coprecipitation with... [Pg.214]

The outline of the construction of a typical plasma emission spectrometer is to be seen in Figure 8.10. The example shown has an inductively coupled plasma, excitation source, but the outline would be similar were a dc source to be fitted. Different combinations of prisms and diffraction gratings may be used in the dispersion of the emitted radiation, and in the presentation of the analytical signal. Instruments are computerized in operation and make use of automatic sample handling. Sophisticated data handling packages are employed routinely to deal with interferences, and to provide for clarity in data output. [Pg.299]

Kola H, Peramaki P, Valimaki I. Correction of spectral interferences of calcium in sulfur determination by inductively coupled plasma optical emission spectroscopy using multiple hnear regression. J. Anal. At. Spectrom. 2002 17 104-108. [Pg.317]

Dulski, P. (1994). Interferences of oxide, hydroxide and chloride analyte species in the determination of rare earth elements in geological samples by inductively coupled plasma-mass spectrometry. Fresenius Journal of Analytical Chemistry 350 194-203. [Pg.360]

The current generation of inductively coupled plasma emission spectrometers provide limits of detection in the range of 0.1-500pg L 1 in solution, a substantial degree of freedom from interferences and a capability for simultaneous multi-element determination facilitated by a directly proportional response between the signal and the concentration of the analyte over a range of about five orders of magnitude. [Pg.39]

The major anions and cations in seawater have a significant influence on most analytical protocols used to determine trace metals at low concentrations, so production of reference materials in seawater is absolutely essential. The major ions interfere strongly with metal analysis using graphite furnace atomic absorption spectroscopy (GFAAS) and inductively coupled plasma mass spectroscopy (ICP-MS) and must be eliminated. Consequently, preconcentration techniques used to lower detection limits must also exclude these elements. Techniques based on solvent extraction of hydrophobic chelates and column preconcentration using Chelex 100 achieve these objectives and have been widely used with GFAAS. [Pg.50]

Date AR, Ying Y, Stuart ME (1987) The influence of polyatomic ion interferences in analysis by inductively coupled plasma source mass spectrometry (ICP-MS). Spectrochim Acta 42B 3-20... [Pg.147]

Gillson GR, Douglas DJ, Fulford JE, Halligan KW, Tanner SD (1988) Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry. Anal Chem 60 1472-1474 Gonfiantini R, Valkiers S, Taylor PDP, De Bievre P (1997) Adsorption in gas mass spectrometry. II Effects on the measurement of isotope amount ratios. Int J Mass Spectrom Ion Proc 171 231-242 Habfast K (1997) Advanced isotope ratio mass spectrometry. I magnetic isotope ratio mass spectrometers. In Modem Isotope Ratio Mass Spectrometry. Chemical Analysis Vol. 145. Platzner IT (ed). John Wiley and Sons, Chichester UK, p 11-82... [Pg.148]

Jackson SE, Gunther D (2003) The nature and sources of laser induced isotopic fractionation in laser ablation-multicollector-inductively coupled plasma-mass spectrometry. J Anal At Spectrom 18 205-212 Jiang S-J, Houk RS, Stevens MA (1988) Alleviation of overlap interferences for determination of potassium isotope ratios by Inductively-Coupled Plasma Mass Spectrometry. Anal Chem 60 1217-1220 Lam JWH, Horlick G (1990) A comparison of argon and mixed gas plasmas for inductively coupled plasma-mass spectrometry. Spectrochim Acta Part B 45 1313-1325 Langmuir I, Kingdon KH(1925) Thermionic effects caused by vapours of alkali metals. Phil Trans R Soc A107 61-79... [Pg.148]

Flame AAS (often abbreviated FAAS) was until recently the most widely used method for trace metal analysis. However, it has now largely been superseded by inductively coupled plasma atomic emission spectrometry (see Chapter 4). It is particularly applicable where the sample is in solution or readily solubilized. It is very simple to use and, as we shall see, remarkably free from interferences. Its growth in popularity has been so rapid that on two occasions, the mid-1960s and the early 1970s, the growth in sales of atomic absorption instruments has exceeded that necessary to ensure that the whole face of the globe would be covered by atomic absorption instruments before the end of the century. [Pg.15]

Line Coincidence Tables for Inductively Coupled Plasma Atomic Emission Spectrometry, Boumans, P.W.J.M, Pergamon Press, New York, 1984. The most comprehensive compilation available of sensitive lines for use in ICPAES, with listings of potential interferences. [Pg.185]

M. Rupprecht and T. Probst, Development of a method for the systematic use of bilinear multivariate calibration methods for the correction of interferences in inductively coupled plasma-mass spectrometry. Anal. Chim. Acta, 358, 1998, 205-225. [Pg.49]

P. Zhang, D. Littlejohn and P. Neal, Mathematical prediction and correction of interferences for optimisation of line selection in inductively coupled plasma optical emission spectrometry, Spectrochim. Acta, Part B, 48(12), 1993, 1517-1535. [Pg.242]

Z. Zhang and X. Ma, Methods for correction of spectral interferences in inductively coupled plasma atomic emission spectrometry, Ciirr. Top. Anal. Chem., 3, 2002, 105-123. [Pg.280]


See other pages where Inductively coupled plasma interferences is mentioned: [Pg.524]    [Pg.177]    [Pg.317]    [Pg.319]    [Pg.530]    [Pg.39]    [Pg.288]    [Pg.614]    [Pg.231]    [Pg.261]    [Pg.606]    [Pg.237]    [Pg.244]    [Pg.245]    [Pg.58]    [Pg.253]    [Pg.118]    [Pg.149]    [Pg.323]    [Pg.1096]    [Pg.20]    [Pg.1548]    [Pg.28]    [Pg.28]    [Pg.34]    [Pg.43]    [Pg.84]    [Pg.95]    [Pg.130]    [Pg.131]    [Pg.158]    [Pg.515]    [Pg.358]   
See also in sourсe #XX -- [ Pg.170 ]




SEARCH



Coupled Plasma

Induction-coupled plasma

Inductive coupled plasma

Inductive coupling

Inductively couple plasma

Inductively coupled

Inductively coupled plasma isotope interferences

Inductively coupled plasma isotope isobaric interferences

Inductively coupled plasma mass interferences

Inductively coupled plasma mass isobaric interferences

Inductively coupled plasma mass spectrometry spectral interferences

Inductively coupled plasma mass spectroscopic interferences

Inductively coupled plasma-atomic emission interferences

Inductively coupled plasma-mass spectrometry interferences

Spectral interferences in inductively coupled plasma

© 2024 chempedia.info