Inductively coupled plasma mass spectroscopic interferences

Bjorn E, Freeh W, Hoffmann E, Liidke C (1998) Investigation and quantification of spectroscopic interferences from polyatomic species in inductively coupled plasma mass spectrometry using electrothermal vaporization or pneumatic nebulization for sample introduction. Spectrochim Acta 53B 1766... [Pg.237]

Other elements were measured by a Perkin-Elmer SCIEX ELAN 6100 DRCII Inductively Coupled Plasma Mass Spectrometry (ICP-MS) instrument equipped with a cyclonic spray chamber, a concentric nebulizer and a dynamic reaction cell (DRC). In the vented (standard) mode, no reaction gas is present in the cell and the instrument shows the typical characteristics of a quadrupole-based ICP-MS apparatus. When the gas is introduced into the cell an ion-molecule reaction takes place that can be tailored so as to eliminate spectroscopic interferences. Experimental conditions are summarized in Table 10.2. [Pg.337]

G. R. Gillson, D. J. Douglas, J. E. Fulford, R. W. Halligan, S. D. Tanner, Non-spectroscopic interelement interferences in inductively coupled plasma mass spectrometry, Anal. Chem., 60 (1988), 1472-1474. [Pg.589]

Effect of ion-iens tuning and flow injection on non-spectroscopic matrix interferences in inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 5(6), 445-451. [Pg.187]

Evans, E. H., and Caruso, J. A. (1992). Optimization strategies for the reduction of non-spectroscopic interferences in inductively coupled plasma mass spectrometry. Spectrochim. Acta, Part B47B(8), 1001. [Pg.210]

Moens, L., and Jakubowski, N. (1998). Double-focusing mass spectrometers in ICPMS— From its very first days, the Achilles heel of inductively coupled plasma MS has been the number of spectroscopic and nonspectroscopic interferences. The only general method to overcome this limitation is to go to high mass resolution with a double-focusing instrument. Anal. Chem. 70(7), 251 A. [Pg.244]


See other pages where Inductively coupled plasma mass spectroscopic interferences is mentioned: [Pg.261]    [Pg.237]    [Pg.1599]    [Pg.1046]    [Pg.141]    [Pg.1575]   
See also in sourсe #XX -- [ Pg.30 ]




SEARCH



Coupled Plasma

Induction-coupled plasma

Inductive coupled plasma

Inductive coupling

Inductively couple plasma

Inductively coupled

Inductively coupled plasma interferences

Inductively coupled plasma mass

Inductively coupled plasma mass interferences

Inductively coupled plasma spectroscop

Mass interference

Mass plasma

© 2024 chempedia.info