ICP inductively coupled plasma spectrometer

Two methods were used to determine the purity of the final material. The ash content was obtained by calculation of a weight loss of 1 g size graphite sample, after its exposure to 900°C for 4 hours (Superior Graphite AIMS procedure FBQ0001). This test gives a good idea of the total amount of impurities. The nature of impurities and their specific concentrations as measured in ppm or ppb levels, was determined with an ICP inductively coupled plasma spectrometer (Model Jobin Yvon Ultima POXX/681,... [Pg.232]

Abbreviations. DSC, differential scanning calorimetry ICP, Inductively coupled plasma spectrometer AA, Atomic absorption. [Pg.175]

If a sample solution is introduced into the center of the plasma, the constituent molecules are bombarded by the energetic atoms, ions, electrons, and even photons from the plasma itself. Under these vigorous conditions, sample molecules are both ionized and fragmented repeatedly until only their constituent elemental atoms or ions survive. The ions are drawn off into a mass analyzer for measurement of abundances and mJz values. Plasma torches provide a powerful method for introducing and ionizing a wide range of sample types into a mass spectrometer (inductively coupled plasma mass spectrometry, ICP/MS). [Pg.87]

Recently it has been shown that rotating coiled columns (RCC) can be successfully applied to the dynamic (flow-through) fractionation of HM in soils and sediments [1]. Since the flow rate of the extracting reagents in the RCC equipment is very similar to the sampling rate that is used in the pneumatic nebulization in inductively coupled plasma atomic emission spectrometer (ICP-AES), on-line coupling of these devices without any additional system seems to be possible. [Pg.459]

In Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES), a gaseous, solid (as fine particles), or liquid (as an aerosol) sample is directed into the center of a gaseous plasma. The sample is vaporized, atomized, and partially ionized in the plasma. Atoms and ions are excited and emit light at characteristic wavelengths in the ultraviolet or visible region of the spectrum. The emission line intensities are proportional to the concentration of each element in the sample. A grating spectrometer is used for either simultaneous or sequential multielement analysis. The concentration of each element is determined from measured intensities via calibration with standards. [Pg.48]

The inductively coupled plasma and the torch used in ICPMS are similar to that used in ICP-OES. In ICPMS, the torch is aimed horizontally at the mass spectrometer, rather than vertically, as in ICP-OES. In ICPMS the ions must be transported physically into the mass spectrometer for analysis, while in ICP-OES light is trans-... [Pg.626]

Pd removal was determined as follows. An aliquot of a representative liquid or solid sample was accurately weighed and subsequently digested by refluxing in nitric and/or hydrochloric acid using a closed vessel microwave procedure (CEM MARS5 Xpress or Milestone Ethos EZ). Cooled, digested samples were diluted, matrix matched to standards, and referenced to a linear calibration curve for quantitation an internal standard was employed to improve quantitation. All samples were analyzed by an Inductively Coupled Plasma Mass Spectrometer or ICP/MS (Perkin Elmer SCIEX Elan DRCII) operated in the standard mode. [Pg.54]

The chemical composition of the samples was determined using an inductively Coupled plasma atomic emission spectrometer (ICP-AES) JY 38 from Jobin Yvon. Specific surface area values were determined by BET method using a Micromeritics Instrument Corp. FlowSorb 2300. The basicity of the materials was studied by temperature programmed desorption (TPD) of C02 used as a probe molecule. The equipment was described in a previous work [7]. FTIR spectra of pellets pressed at 2.5xl08 Pa were recorded with a Vector 22 spectrometer from Brucker. The samples were diluted with KBr (lOOmg KBr - 1.5mg of the sample). [Pg.298]

A Thermo Finnigan Element 2 Inductively Coupled Plasma Sector-Field Mass Spectrometer (ICP-SF-MS) with guard electrode was employed for trace element analyses. RSD values derived from internal check standard never exceeded 10%. Accuracy was better than 15% for all elements as determined by analyzing the certified reference standard NWRI TM-RAIN 95 trace metal fortified rainwater, every 5 to 8 samples. [Pg.208]

The instrument which uses this plasma torch is called an inductively coupled plasma atomic emission spectrometer (ICP-AES) or an inductively coupled plasma optical emission spectrometer (ICP-OES). It is similar to an... [Pg.57]

The inductively coupled plasma (ICP) technique described in Chapter 9 (Section 9.5) has been coupled with mass spectrometry. The ICP source provides the mass spectrometer with a source of charged monatomic ions such that the electron beam is not needed. The exhaust of the ICP source is fed into the mass spectrometer for analysis by the mass analyzer portion of the mass spectrometer (Figure 10.20). [Pg.290]

In Inductively Coupled Plasma Mass Spectrometry. Montaser A (ed) Wiley-VCH, New York, p 83-264 Montaser A, Zhang H (1998) Mass spectrometry with mixed-gas and Helium ICPS. In Inductively Coupled Plasma Mass Spectrometry. Montaser A (ed), Wiley-VCH, New York, p 809-890 Nier AO (1940) A mass spectrometer for routine isotope abundances measurement. Rev Sci Instrum 11 212-216... [Pg.149]

Powder X-ray diffraction (XRD) data were collected via a Siemens D5005 diffractometer with CuKa radiation (A. = 1.5418 A). Routine transmission electron microscopy (TEM) and Z-contrast microscopy were carried out using an HITACH HD-2000 scanning transmission electron microscope (STEM) operated at 200 kV. Nitrogen gas adsorption measurements (Micromeritics Gemini) were used to determine the surface area and porosity of the catalyst supports. Inductively coupled plasma (ICP) analysis was performed via an IRIS Intrepid II XSP spectrometer (Thermo Electron Corporation). [Pg.58]

The uranium series dating is based on the determination of the U/ °Th or 235 /23 Isotopic ratio measurements can be made by means of a mass spectrometer. Multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS)... [Pg.29]

Inductively coupled plasma (ICP) mass spectrometers use a hot plasma to ionize the sample. The plasma is generated by electromagnetic induction. The plasma source operates at... [Pg.527]


See other pages where ICP inductively coupled plasma spectrometer is mentioned: [Pg.14]    [Pg.285]    [Pg.22]    [Pg.285]    [Pg.400]    [Pg.402]    [Pg.317]    [Pg.58]    [Pg.407]    [Pg.214]    [Pg.166]    [Pg.202]    [Pg.29]    [Pg.336]    [Pg.406]    [Pg.12]    [Pg.58]    [Pg.119]    [Pg.110]    [Pg.376]    [Pg.113]    [Pg.118]    [Pg.4]    [Pg.28]    [Pg.29]    [Pg.35]    [Pg.36]    [Pg.95]    [Pg.118]    [Pg.120]   
See also in sourсe #XX -- [ Pg.215 , Pg.216 ]

See also in sourсe #XX -- [ Pg.215 , Pg.216 ]

See also in sourсe #XX -- [ Pg.215 , Pg.216 ]




SEARCH



Coupled Plasma

ICP inductively coupled plasma

Induction-coupled plasma

Inductive Coupled Plasma Mass Spectrometer ICP-MS)

Inductive coupled plasma

Inductive coupling

Inductively Coupled Plasma Mass Spectrometers (ICP-MS)

Inductively couple plasma

Inductively coupled

Inductively coupled plasma spectrometer

Laser Ablation Inductively Coupled Plasma Mass Spectrometers (LA-ICP-MS)

© 2024 chempedia.info