Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Holding voltage

There is also another quantum limit, called the "Coulomb blockade" [20] If an electron is confined to a small dot—that is, a two-dimensional confined region, or quantum dot—of capacitance C (typically 1 fF), then adding another electron will cost a "charging energy" e1 /C. If (ez/2C) Coulomb blockade occurs No more charges can be added, until the thresh-hold voltage... [Pg.455]

Batrachotoxin is an important research tool because of its action of holding voltage-gated sodium channels open as well as its specific effects at other ligandbinding sites. It was previously used commonly in channel and ligand research. There are no commercially available stocks of batrachotoxins, however, and work in Colombia is currently difficult or impossible, so these chemicals are used less frequently in research. [Pg.216]

The second problem that now plagues chip designers is a power crisis. The scaling laws of Dennard and co-workers predict that power density should remain constant even as the number of transistors and their switching speed increase. However, for that prediction to hold, voltages have to be reduced in proportion to the linear dimensions of the transistor. In reality, chip manufacturers have not been able to lower operating voltages that steeply... [Pg.156]

The value of the holding voltage Vj for 1 urn thick chalcogenide films is typically Vj 1 volt with electrodes of Mo, W, Ta, and nichrome and Vj l.S volt for carbon electrodes. A small magnitude of is desirable because it governs for a certain current value the Joule heating generated. [Pg.326]

Measurement of the battery voltage drop (rfVJ is very difficult to capture, therefore the pulse duration (dt) is minimized to reduce the polarization effect voltage drop (dV2). The pulse duration is generally kept in the range of 5 to 50 milliseconds. For accurate and repetitive results, it is recommended that duration times be kept constant by read and hold voltage measurements. [Pg.213]

The 180° twisted Heilmeier displays show switch-off behavior similar to r-cells. It takes a long relaxation time to return to the quiescent state after a very fast decay to an intermediate level. This long relaxation is undesirable, and a 180° Heilmeier shutter can function reasonably only after using a holding voltage similar to that of r-cells. [Pg.1260]


See other pages where Holding voltage is mentioned: [Pg.341]    [Pg.218]    [Pg.136]    [Pg.275]    [Pg.277]    [Pg.328]    [Pg.324]    [Pg.328]    [Pg.351]    [Pg.352]    [Pg.26]    [Pg.409]    [Pg.351]    [Pg.352]    [Pg.265]    [Pg.423]    [Pg.396]    [Pg.68]    [Pg.1650]   
See also in sourсe #XX -- [ Pg.326 ]




SEARCH



Holde

Holding

Holds

© 2024 chempedia.info