Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

High sensitivity

In vapor-liquid equilibria, it is relatively easy to start the iteration because assumption of ideal behavior (Raoult s law) provides a reasonable zeroth approximation. By contrast, there is no obvious corresponding method to start the iteration calculation for liquid-liquid equilibria. Further, when two liquid phases are present, we must calculate for each component activity coefficients in two phases since these are often strongly nonlinear functions of compositions, liquid-liquid equilibrium calculations are highly sensitive to small changes in composition. In vapor-liquid equilibria at modest pressures, this sensitivity is lower because vapor-phase fugacity coefficients are usually close to unity and only weak functions of composition. For liquid-liquid equilibria, it is therefore more difficult to construct a numerical iteration procedure that converges both rapidly and consistently. [Pg.4]

The specific nature of UV absorption for certain structures when combined with the high sensitivity of the method enables trace quantities (— 1 ppm) of molecules in a matrix transparent to UV beams to be analyzed. Benzene in cyclohexane is an example. [Pg.56]

In order to test the economic performance of the project to variations in the base case estimates for the input data, sensitivity analysis is performed. This shows how robust the project is to variations in one or more parameters, and also highlights which of the inputs the project economics is more sensitive to. These inputs can then be addressed more specifically. For example if the project economics is highly sensitive to a delay in first production, then the scheduling should be more critically reviewed. [Pg.325]

The only meaningful solution is a pneumatic test in conjunction with an AE. Beside the high sensitivity of an AE and its reliability in combination with an established and proven data base, the method can be performed by experienced testing agencies easily and within short shut down period. A lot of 4 up to 9 drums can be tested within one day. [Pg.34]

High sensitivity for both small surface cracks and bigger inner fractures and corrosive defects under the layer of a non - magnetic metal to 7 mm, also through the skins. [Pg.343]

A method that would enable detection and classification of the bone content in 100% of the incoming frozen fish blocks in real time without delaying the production line was desired. An obvious solution to this was the use of X-ray inspection. X-ray inspection however requires the integration of a highly sensitive inspection equipment with the corrosive atmosphere associated with food processing as well as the tough restrictions imposed by the health authorities regarding irradiation of food. [Pg.587]

Polar penetrants must be used only with suspension developers to ensure high sensitivity of PT. [Pg.618]

The properties of the piezocomposite material mentioned above offer special benefits when the transducer is coupled to a material of low acoustic impedance. This especially applies to probes having plastic delay lines or wedges and to immersion and medical probes. These probes with piezocomposite elements can be designed to have not only a high sensitivity but also at the same time an excellent resolution and, in addition, the effort required for the probe s mechanical damping can be reduced. [Pg.709]

THz. Therefore, for laboratory absorption experiments, a typical FIR detector provides an estimated detection limit (NEP/source power) of 10 with a source output of 20 nW. In general, high-sensitivity bolometers... [Pg.1235]

NMR is an important teclnhque for the study of flow and diflfiision, since the measurement may be made highly sensitive to motion without in any way influencing the motion under study. In analogy to many non-NMR-methods, mass transport can be visualized by imaging the distribution of magnetic tracers as a fiinction of time. Tracers may include paramagnetic contrast agents which, in particular, reduce the transverse... [Pg.1534]

The advantages of SIMS are its high sensitivity (ppm detection limit for certain elements), its ability to detect hydrogen and the emission of molecular fragments which often bear tractable relationships with the parent... [Pg.1860]

Luminescence has been used in conjunction with flow cells to detect electro-generated intennediates downstream of the electrode. The teclmique lends itself especially to the investigation of photoelectrochemical processes, since it can yield mfonnation about excited states of reactive species and their lifetimes. It has become an attractive detection method for various organic and inorganic compounds, and highly sensitive assays for several clinically important analytes such as oxalate, NADH, amino acids and various aliphatic and cyclic amines have been developed. It has also found use in microelectrode fundamental studies in low-dielectric-constant organic solvents. [Pg.1948]

The reactivity of size-selected transition-metal cluster ions has been studied witli various types of mass spectrometric teclmiques [1 ]. Fourier-transfonn ion cyclotron resonance (FT-ICR) is a particularly powerful teclmique in which a cluster ion can be stored and cooled before experimentation. Thus, multiple reaction steps can be followed in FT-ICR, in addition to its high sensitivity and mass resolution. Many chemical reaction studies of transition-metal clusters witli simple reactants and hydrocarbons have been carried out using FT-ICR [49, 58]. [Pg.2394]


See other pages where High sensitivity is mentioned: [Pg.105]    [Pg.106]    [Pg.160]    [Pg.322]    [Pg.322]    [Pg.368]    [Pg.382]    [Pg.469]    [Pg.505]    [Pg.538]    [Pg.538]    [Pg.545]    [Pg.585]    [Pg.708]    [Pg.711]    [Pg.723]    [Pg.723]    [Pg.725]    [Pg.728]    [Pg.830]    [Pg.1060]    [Pg.466]    [Pg.562]    [Pg.1058]    [Pg.1163]    [Pg.1164]    [Pg.1244]    [Pg.1246]    [Pg.1298]    [Pg.1561]    [Pg.1564]    [Pg.1792]    [Pg.1800]    [Pg.1800]    [Pg.1828]    [Pg.1940]    [Pg.2483]    [Pg.2484]   
See also in sourсe #XX -- [ Pg.152 , Pg.153 ]




SEARCH



Applications of Small-Volume High-Sensitivity and Cryogenic NMR Probes

Catalysis high sensitivity requirement

Detector high sensitivity

Determination of dissolved inorganic phosphate by an extraction procedure (high-sensitivity method)

Drug discovery high-sensitivity

Enzymes, Transporters, and Drugs Highly Sensitive to Induction

Exercise high-sensitivity

Fluorescence spectroscopy high sensitivity

General Principles, NMR as a Highly Sensitive Analytical Tool (pg to ng Amounts)

High assay sensitivity

High concentration-sensitive

High detection sensitivity

High mass sensitive

High sensitivity Doppler broadening

High sensitivity detection cell

High sensitivity interface

High-Sensitivity Detection Methods

High-Sensitivity FIA

High-Sensitivity Methods of Absorption Spectroscopy

High-performance liquid chromatography operational sensitivity

High-pressure surface-sensitive techniques

High-pressure surface-sensitive techniques spectroscopy

High-sensitivity DSC

High-sensitivity Determination Relationship of Sample Volume to Peak Height

High-sensitivity electrophoresis

High-sensitivity hydrophones

High-sensitivity stop-flow

High-sensitivity white-light absorption

High-sensitivity white-light absorption diamond films

High-sensitivity white-light absorption spectroscopy

High-throughput Screening of Hormone-sensitive Lipase and Subsequent Computer-assisted Compound Optimization

Highly sensitive detection

Highly sensitive detection chemiluminescence

Highly sensitive detection derivatizing reagents, 7

Highly sensitive pH-responsive

Kinetic sensitivity analysis, high-speed

Mass analysis high-sensitivity

Mechanisms of Highly Sensitive Detection

Microfluidic Systems Sensitivity, High Speed

Other Uses of High-Sensitivity White-Light Absorption Spectroscopy

Peptides high sensitivity sequence analysis

Pharmaceutical applications, high-sensitivity

Pharmaceutical applications, high-sensitivity biological molecules

Pressure-sensitive adhesives high-tack formulation

Sedimentation methods, high sensitivity

Sensitive High Resolution Ion MicroProbe

Sensitive High Resolution Ion MicroProbe SHRIMP)

Sensitive high resolution ion

Sensitiveness high explosives

Sensitivity analysis high-resolution mass spectrometry

Sensitivity high-performance liquid chromatography

Sensitivity of High Explosives to Detonators

Sensitization high nickel alloys

Sensitizer highly bulky

The Order of Sensitivity for Highly Sensitive Substances

The Uses of High-Sensitivity White-Light Absorption Spectroscopy in Other CVD Environments

Tryptic digests, high sensitivity detection

© 2024 chempedia.info