As a method of research, has been used high-performance liquid chromatography in reversed - phase regime (RP HPLC). The advantage of the present method is the following the additional information about AIST and FAS composition (homologous distribution) simple preparation of samples (dilution of a CS sample of in a mobile phase). [Pg.133]

Selectivity of chromatographic separation is known to be varied by changing both the nonstationary phase composition and adsorbent nature. It is shown that the less are the values of the reached selectivity coefficient the higher are the requirements to column effectiveness. In this connection the choice of stationai y phase with high and predicted selectivity coefficient for the compounds being separated is still remains a topical problem of high-performance liquid chromatography. [Pg.138]

The principle was demonstrated using triazine herbicides as templates and by varying the type of functional monomer and the monomer composition. With a final batch size of ca. 40 mg of monomer, the consumption of monomers and template is significantly reduced and the synthesis and evaluation can take place in standard high-performance liquid chromatography (UPLC) autosample vials. After synthesis. [Pg.176]

In 1979, it was stated that poiybrominated aromatic ethers have received little attention (ref. 1). That statement is still applicable. Analyses to characterize this class of commercial flame retardants have been performed using UV (refs. 1-2), GC (refs. 1-6), and GC-MS (refs. 1-4). The bromine content of observed peaks was measured by GC-MS, but no identification could be made. The composition of poiybrominated (PB) diphenyl ether (DPE) was predicted from the expected relationship with polyhalogenated biphenyl, a class which has received extensive attention. NMR (refs. 3-6) was successfully used to identify relatively pure material which had six, or fewer, bromine atoms per molecule. A high performance liquid chromatography (HPLC) method described (ref. 1) was not as successful as GC. A reversed phase (RP) HPLC method was mentioned, but no further work was published. [Pg.399]

Schreuder, R. H., Martijn, A., Poppe, H., and Kraak, J. C., Determination of the composition of ethoxylated alkylamines in pesticide formulations by high-performance liquid chromatography using ion pair extraction detection, /. Chromatogr., 368, 339, 1986. [Pg.194]

Amadi, E. N. Alderson, G. Menaquinone composition of some micrococci determined by high performance liquid chromatography. J. Appl. Bacteriol. 1991, 70, 517-521. [Pg.198]

One way to determine the fatty acid composition of a plant oil is by the technique of high-performance liquid chromatography. This technique is a separation... [Pg.203]

Because of the instability of cyanohydrins, the characterization of cyanohydrins mostly should be hydroxyl protected. In 2001, Gerrits et al. [26] investigated the influence of solvent composition on the stability of unprotected cyanohydrins and then described a method to analyze unprotected cyanohydrins (with regard to enantiomeric purity and conversion) via chiral high-performance liquid chromatography (HPLC). Hernandez et al. [27] and the groups... [Pg.108]

Raman often is evaluated as an alternative to an existing high performance liquid chromatography (HPLC) method because of its potential to be noninvasive, fast, simple to perform, and solvent-free. Raman was compared to HPLC for the determination of ticlopidine-hydrochloride (TCL) [43], risperidone [44] in film-coated tablets, and medroxyprogesterone acetate (MPA) in 150-mg/mL suspensions (DepoProvera, Pfizer) [45] it was found to have numerous advantages and performance suitable to replace HPLC. In an off-line laboratory study, the relative standard deviation of the measurement of the composition of powder mixtures of two sulfonamides, sulfathiazole and sulfanilamide, was reduced from 10-20% to less than 4% by employing a reusable, easily prepared rotating sample cell [46]. [Pg.209]

High Performance Liquid Chromatography High Performance Liquid Chromatography (HPLC) is an analytical chemical method which is used on a large scale routinely. If an HPLC method is developed, the question arises whether the analytical results from this method depend critically on small deviations in the mobile phase composition, the selected UV-wavelength for detection etc. [Pg.3]

TLC differs in many aspects from High Performance Liquid Chromatography (HPLC). The first difference is that the solutes are not separated over a fixed length (the separation column) but during a fixed time (the development time). Therefore, the chromatographic behaviour is not characterized by the time needed to traverse the column, but by distance travelled within a certain time span. A second difference is that the composition of the mobile phase may vary over the length of the plate. More volatile components may vaporize causing a different composition at different places on the TLC plates. [Pg.234]

NMR spectroscopy ( Se, /= 1/2, 7%) is a powerful technique for identifying cyclic selenium molecules, especially the heteroatomic ring systems that contain sulfur or tellurium in addition to selenium, for which several isomers are possible for most compositions (Section 12.1.2). Solutions of monoclinic selenium in CS2 have been shown by high-performance liquid chromatography to form an equilibrium mixture of cyclo-Seg, cyclo-Sey and cyclo-Se6. The Se NMR spectra of such solutions show two singlets that are attributable to cyclo-Seg and cyclo-Se with relative intensities that correspond to a molar ratio of ca 6 No resonance is observed for cyclo-Sey presumably as a result of the fluxional behaviour (pseudorotation) of the seven-membered ring (Section 12.1.2). [Pg.278]

Table 5.4.11 High-performance liquid chromatography (HPLC) mobile phase gradient composition (adapted from [31])... Table 5.4.11 High-performance liquid chromatography (HPLC) mobile phase gradient composition (adapted from [31])...
The chemical properties of HVA, 5HIAA and 3-MD make them amenable to reverse-phase high-performance liquid chromatography (HPLC) with electrochemical detection. Furthermore, the composition of CSF means that little, if any, sample preparation is required prior to analysis. However, the susceptibility of these metabolites to oxidation means that careful sample collection and storage is required in order to minimise analyte degradation. [Pg.704]


See other pages where High-performance liquid chromatography composition is mentioned: [Pg.773]    [Pg.133]    [Pg.136]    [Pg.145]    [Pg.160]    [Pg.60]    [Pg.465]    [Pg.261]    [Pg.136]    [Pg.100]    [Pg.13]    [Pg.139]    [Pg.515]    [Pg.158]    [Pg.146]    [Pg.213]    [Pg.46]    [Pg.50]    [Pg.246]    [Pg.248]    [Pg.124]    [Pg.205]    [Pg.579]    [Pg.35]    [Pg.47]    [Pg.59]    [Pg.264]    [Pg.223]    [Pg.626]    [Pg.295]    [Pg.166]    [Pg.11]    [Pg.799]    [Pg.364]   
See also in sourсe #XX -- [ Pg.499 , Pg.500 , Pg.501 , Pg.502 , Pg.503 , Pg.504 , Pg.505 , Pg.506 , Pg.507 , Pg.508 ]

See also in sourсe #XX -- [ Pg.1703 ]