Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Glucose electrochemical

Li, Y Song, Y.-Y Yang, C. Xia, X.-H. Hydrogen bubble dynamic template synthesis of porous gold for nonenzymatic electrochemical detection of glucose. Electrochem. Commun. 2007, 9,981—988. [Pg.393]

Scale of Operation Voltammetry is routinely used to analyze samples at the parts-per-million level and, in some cases, can be used to detect analytes at the parts-per-billion or parts-per-trillion level. Most analyses are carried out in conventional electrochemical cells using macro samples however, microcells are available that require as little as 50 pL of sample. Microelectrodes, with diameters as small as 2 pm, allow voltammetric measurements to be made on even smaller samples. For example, the concentration of glucose in 200-pm pond snail neurons has been successfully monitored using a 2-pm amperometric glucose electrode. ... [Pg.531]

Entrapment of biochemically reactive molecules into conductive polymer substrates is being used to develop electrochemical biosensors (212). This has proven especially useful for the incorporation of enzymes that retain their specific chemical reactivity. Electropolymerization of pyrrole in an aqueous solution containing glucose oxidase (GO) leads to a polypyrrole in which the GO enzyme is co-deposited with the polymer. These polymer-entrapped GO electrodes have been used as glucose sensors. A direct relationship is seen between the electrode response and the glucose concentration in the solution which was analyzed with a typical measurement taking between 20 to 40 s. [Pg.45]

Later on, such S-layer-based sensing layers were also used in the development of optical biosensors (optodes), where the electrochemical transduction principle was replaced by an optical one [97] (Fig. 10c). In this approach an oxygen-sensitive fluorescent dye (ruthenium(II) complex) was immobilized on the S-layer in close proximity to the glucose oxidase-sensing layer [97]. The fluorescence of the Ru(II) complex is dynamically quenched by molecular oxygen. Thus, a decrease in the local oxygen pressure as a result of... [Pg.356]

Accord, W. and Feldman, F. J. Design consideration for a fully automated rate electrochemical glucose and urea nitrogen analyzer. Clin. Chem. (1974), 20, 903. [Pg.150]

Homogeneous electrochemical enzyme immunoassays for both phenytoin and digoxin have been developed. In both cases the label was glucose-6-phosphate dehydrogenase, which catalyzes the reduction of NAD to NADH. The NADH produced was detected by LCEC at a carbon paste electrode. [Pg.34]

The electrolytes Na", and Cl are second only to glucose in being the most frequently run hospital tests. Many clinical chemistry analyzers now contain an ISE module for electrolyte analysis. Most commonly the module will consist of a Na -glass electrode, a valinomycin/PVC electrode, a Ag/AgCl pellet or a quaternary ammonium ion/PVC electrode and a reference electrode. A selective electrode for the bicarbonate ion continues to elude workers in the field. An indirect measurement of HCOf must be made. The sample is usually reacted with acid to evolve carbon dioxide gas which is measured with a traditional Severinghaus type CO2 electrode. Alternatively, the sample is treated with base to convert HCO to CO3 and a carbonate ion-selective electrode is used In this manner, the complete primary electrolyte profile is obtained electrochemically. [Pg.61]

The demand for monitoring common metabolites of diagnostic utility such as glucose, urea and creatinine continue to provide the impetus for a staggering research effort towards more perfect enzyme electrodes. The inherent specificity of an enzyme for a given substrate, coupled with the ability to electrochemically detect many of the products of enzymatic reactions initiated the search for molecule-selective electrodes. [Pg.62]

Many dehydrogenase enzymes catalyze oxidation/reduction reactions with the aid of nicotinamide cofactors. The electrochemical oxidation of nicotinamide adeniiw dinucleotide, NADH, has been studied in depthThe direct oxidation of NADH has been used to determine concentration of ethanol i s-isv, i62) lactate 157,160,162,163) pyTuvate 1 ), glucose-6-phosphate lactate dehydrogenase 159,161) alanine The direct oxidation often entails such complications as electrode surface pretreatment, interferences due to electrode operation at very positive potentials, and electrode fouling due to adsorption. Subsequent reaction of the NADH with peroxidase allows quantitation via the well established Clark electrode. [Pg.65]

Figure 17.10 Electrocatalytic current (per geometric area) versus potential for glucose oxidation by glucose oxidase in an Os-containing redox polymer supported on carbon nanotubes grown for various periods (times indicated) on carbon paper. Reproduced by permission of ECS—The Electrochemical Society, from Barton et al., 2007. Figure 17.10 Electrocatalytic current (per geometric area) versus potential for glucose oxidation by glucose oxidase in an Os-containing redox polymer supported on carbon nanotubes grown for various periods (times indicated) on carbon paper. Reproduced by permission of ECS—The Electrochemical Society, from Barton et al., 2007.
Binyamin G, Heller A. 1999. Stabilization of wired glucose oxidase anodes rotating at 1000 rpm at 37°C. J Electrochem Soc 146 2965-2967. [Pg.630]

Kynaston, J. A., Fleming, S. C., Laker, M. F. and Pearson, A. D. J., Simultaneous quantification of mannitol, 3-O-methyl glucose and lactulose in urine by HPLC with pulsed electrochemical detection, for use in studies of intestinal permeability, Clin. Chem., 39, 453, 1993. [Pg.281]


See other pages where Glucose electrochemical is mentioned: [Pg.503]    [Pg.2326]    [Pg.2030]    [Pg.308]    [Pg.480]    [Pg.293]    [Pg.294]    [Pg.3346]    [Pg.2326]    [Pg.765]    [Pg.503]    [Pg.2326]    [Pg.2030]    [Pg.308]    [Pg.480]    [Pg.293]    [Pg.294]    [Pg.3346]    [Pg.2326]    [Pg.765]    [Pg.45]    [Pg.390]    [Pg.103]    [Pg.176]    [Pg.196]    [Pg.230]    [Pg.43]    [Pg.355]    [Pg.217]    [Pg.428]    [Pg.340]    [Pg.342]    [Pg.411]    [Pg.411]    [Pg.33]    [Pg.71]    [Pg.599]    [Pg.728]    [Pg.366]    [Pg.462]    [Pg.119]    [Pg.120]    [Pg.5]    [Pg.6]    [Pg.16]    [Pg.261]    [Pg.26]    [Pg.29]   
See also in sourсe #XX -- [ Pg.108 , Pg.109 , Pg.110 , Pg.113 , Pg.115 , Pg.117 , Pg.120 ]




SEARCH



Amperometric glucose electrodes based electrochemical steps

Electrochemical applications glucose sensing

Electrochemical glucose biosensors

Electrochemical glucose biosensors history

Glucose catalytic electrochemical

Glucose electrochemical measurements

Glucose electrochemically coupled enzymatic

Glucose oxidase electrochemical deposition

Glucose oxidase, scanning electrochemical

Glucose, electrochemical oxidation

© 2024 chempedia.info