Glucose analyser

Amador, E. Pippert, J. A. Emary, R. J. Serum creatinine and glucose analyses by an automated rapid sampling digital system. Clin. Chem. (1971), 17, 655. [Pg.218]

Other automated systems may be purchased for a specific purpose and are called dedicated instruments, e.g. glucose analyser. Others have fairly restricted applications, an example being the reaction rate analysers which are specifically designed for the kinetic measurements of enzyme activity. Some of the more recently developed instruments employ individual pre-prepared disposable test packs or strip devices which contain all the reagents for each particular assay in a dry form. [Pg.213]

This lead to the development of the first glucose analyser for the measurement of glucose in whole blood (Yellow Springs Instrument 23 YSI, 1974). [Pg.9]

Glucose in pre-treated ice-creams, drinks, molasses and flour has also been determined with a glucose oxidase based nylon electrode. The results were similar to those obtained by the Yellow Springs Instrument glucose analyser and a Boehringer Mannheim glucose test-kit (10). [Pg.114]

A generally ignored pitfall is associated with some glucose analyses, specifically with those methods using glucose oxidase. Such methods are very common since the enzyme is relatively inexpensive and very stable. This enzyme is known to react with (3-D-glucose but not with a-D-glucose (Merck Index). [Pg.50]

Paracetamol can cause false-positive reactions for glucose in serum and blood specimens examined using the YSI glucose analyser. The effect could be of considerable importance in patients admitted with suspected paracetamol overdosage. [Pg.2689]

R155 Smith, L.A., McNaught, J. and Hutchinson, A.S. (1989). How well do nurses perform blood glucose analyses at the diabetic clinic An assessment using the Reflotron analyser. Ann. Clin. Biochem. 26, 554-555. [Pg.430]

Fig. 10. a Correlation of glucose measurement in whole blood, measured by micro-thermometric biosensor and by the Reflolux-S blood glucose analyser, b Correlation of glucose measurement in whole blood measured by micro-thermometric biosensor and by the Ektachem blood glucose analyzer... [Pg.21]

Scheme 1. Setup for simultaneous thermometric and blood-glucose analyser measurements, using a micro-dialysis in-vivo probe on a human volunteer... Scheme 1. Setup for simultaneous thermometric and blood-glucose analyser measurements, using a micro-dialysis in-vivo probe on a human volunteer...
Fig. 11. In-vivo glucose load with a healthy volunteer. Points plotted on the graph (+) are the glucose concentrations measured with a blood glucose analyser and (-) are the peaks of temperature change. The dialysis fiber (10 mm) was inserted subcutaneously. The perfusion rate was 3 pl/min... Fig. 11. In-vivo glucose load with a healthy volunteer. Points plotted on the graph (+) are the glucose concentrations measured with a blood glucose analyser and (-) are the peaks of temperature change. The dialysis fiber (10 mm) was inserted subcutaneously. The perfusion rate was 3 pl/min...
There are probably more blood glucose analyses than any other analytical measurement in the world. [Pg.681]

Kim, B.S., Lee, S.C., Lee, S.Y. et al. (1994) Production of poly(3-hydroxybutyric-co-3-hydroxyvaleric acid) by fed-batch culture of Alcaligenes eutrophus with substrate control using on-line glucose analyser. Enzyme Microbiology and Technology, 16, 556-561. [Pg.169]

Chua KS, Tan IK. Plasma glucose measurement with Yellow Springs glucose analyser. Clinical Chemistry 1978 24(l) 150-2. [Pg.61]


See other pages where Glucose analyser is mentioned: [Pg.303]    [Pg.331]    [Pg.332]    [Pg.52]    [Pg.2689]    [Pg.191]    [Pg.23]    [Pg.171]    [Pg.209]    [Pg.225]    [Pg.261]    [Pg.155]    [Pg.156]    [Pg.261]   
See also in sourсe #XX -- [ Pg.332 ]

See also in sourсe #XX -- [ Pg.181 ]