FTICR Fourier transform ion cyclotron

FTICR. Fourier-transform ion cyclotron resonance GC/IRMS. gas chromatography isotope ratio mass spectrometry... [Pg.445]

B magnetic sector E = electric sector Q = quadrupole mass filter ToF = time-of-flight mass spectrometer IT = ion trap FTICR = Fourier-transform ion-cyclotron resonance. [Pg.386]

FTICR Fourier-transform ion-cyclotron HETCOR Heteronuclear chemical... [Pg.754]

FTICR Fourier Transform Ion Cyclotron Resonance (used... [Pg.195]

Direct-infusion MS is a very interesting approach, especially when sample characteristics allow MS analysis with minimum sample treatment. Thus, ESI can be used to directly ionize analytes in liquid samples in a high electric field. A small flow of the liquid sample is conducted through a capillary to the high electric field for ESI. Usually, sample solutions must be carefully cleaned and filtered to avoid potential capillary blocking. Following this idea, direct-infusion ESI-FTICR (Fourier transform ion cyclotron resonance) MS of a coffee drink combined with partial least-squares multivariate statistical analysis was successfully employed to predict the blend composition of commercial coffee varieties (28). In a different work, minimal sample manipulation was carried out to obtain detailed molecular composition of edible oils and fats analyzed by flow-injection ESI-Orbitrap MS for quality assessment and authenticity control purposes (29). Commonly, when using direct infusion approaches, sample needs to be treated to dissolve the compounds of interest in the appropriate solvent. [Pg.240]

Figure 9.2 The basic components of a mass spectrometer. All mass spectrometers consist of an ion source linked to a mass analyser then to a detector. The important ion sources and mass analysers for biological mass spectrometry are listed. There are many other potential ion sources and mass analysers used generally in mass spectrometry, but only the indicated are of use in the analysis of biological macromolecules and amphiphilic lipids, and also in proteomics FAB fast atom bombardment MALDI matrix-assisted laser desorption and ionization ESI electrospray ionization ToF time of flight FTICR fourier transform ion cyclotron resonance MS/MS tandem mass spectrometry. Figure 9.2 The basic components of a mass spectrometer. All mass spectrometers consist of an ion source linked to a mass analyser then to a detector. The important ion sources and mass analysers for biological mass spectrometry are listed. There are many other potential ion sources and mass analysers used generally in mass spectrometry, but only the indicated are of use in the analysis of biological macromolecules and amphiphilic lipids, and also in proteomics FAB fast atom bombardment MALDI matrix-assisted laser desorption and ionization ESI electrospray ionization ToF time of flight FTICR fourier transform ion cyclotron resonance MS/MS tandem mass spectrometry.
Several techniques have been used to investigate the reactivity of the metal carbide cluster ions formed in a laser vaporization source. The earliest investigations performed by Castleman s group relied on a preliminary mass selection of the desired cluster. The ion beam was then injected into a drift tube where the selected cluster encounters the reactant mixed with helium as a buffer gas. The FTICR (Fourier-transform ion cyclotron resonance) mass spectrometer studies reported by Byun, Freiser and co-workers basically rely on the same principle even though the total pressure of the reaction chamber is 10 torr, compared with 0.7 torr in Castleman s experiments. A new method of forming met-car ligand complexes was then reported by Castleman et al. this involved the direct interaction of the vaporized metal with mixtures of methane and selected reactant gases. ... [Pg.1681]

Fig. 11.14 Tetrahenzoxazines (/f)-3 and (S)-3 and tetrakis-aminomethylated Fesoicinarene (S)-17. Quaternary ammonium ions (18). Isotope pattern regions of the ESI-PTlCR (FTICR Fourier transform ion cyclotron resonance) mass spectra of (S)-17 with pseudo-racemates of the two guests. The bottom row represents control experiments with a reversed labelling of the two guest enantiomers as compared to the top row [35] (Image reproduced frinn [35] with permission from Springer)... Fig. 11.14 Tetrahenzoxazines (/f)-3 and (S)-3 and tetrakis-aminomethylated Fesoicinarene (S)-17. Quaternary ammonium ions (18). Isotope pattern regions of the ESI-PTlCR (FTICR Fourier transform ion cyclotron resonance) mass spectra of (S)-17 with pseudo-racemates of the two guests. The bottom row represents control experiments with a reversed labelling of the two guest enantiomers as compared to the top row [35] (Image reproduced frinn [35] with permission from Springer)...
Other types of mass spectrometer may use point, array, or both types of collector. The time-of-flight (TOF) instrument uses a special multichannel plate collector an ion trap can record ion arrivals either sequentially in time or all at once a Fourier-transform ion cyclotron resonance (FTICR) instrument can record ion arrivals in either time or frequency domains which are interconvertible (by the Fourier-transform technique). [Pg.201]

An added consideration is that the TOF instruments are easily and quickly calibrated. As the mass range increases again (m/z 5,000-50,000), magnetic-sector instruments (with added electric sector) and ion cyclotron resonance instruments are very effective, but their prices tend to match the increases in resolving powers. At the top end of these ranges, masses of several million have been analyzed by using Fourier-transform ion cyclotron resonance (FTICR) instruments, but such measurements tend to be isolated rather than targets that can be achieved in everyday use. [Pg.281]

To check the identity and purity of the products obtained in the above reactions it is not sufficient to analyze for the sulfur content since a mixture may incidentally have the same S content. Either X-ray diffraction on single crystals or Raman spectra of powder-like or crystalline samples will help to identify the anion(s) present in the product. However, the most convincing information comes from laser desorption Fourier transform ion cyclotron resonance (FTICR) mass spectra in the negative ion mode (LD mass spectra). It has been demonstrated that pure samples of K2S3 and K2S5 show peaks originating from S radical anions which are of the same size as the dianions in the particular sample no fragment ions of this type were observed [28]. [Pg.132]

Resolution does not affect the accuracy of the individual accurate mass measurements when no separation problem exists. When performing accurate mass measurements on a given component in a mixture, it may be necessary to raise the resolution of the mass spectrometer wherever possible. Atomic composition mass spectrometry (AC-MS) is a powerful technique for chemical structure identification or confirmation, which requires double-focusing magnetic, Fourier-transform ion-cyclotron resonance (FTICR) or else ToF-MS spectrometers, and use of a suitable reference material. The most common reference materials for accurate mass measurements are perfluorokerosene (PFK), perfluorotetrabutylamine (PFTBA) and decafluorotriph-enylphosphine (DFTPP). One of the difficulties of high-mass MS is the lack of suitable calibration standards. Reference inlets to the ion source facilitate exact mass measurement. When appropriately calibrated, ToF mass... [Pg.356]

Currently PCR and mass spectrometry are performed by two separate instruments. However, there is no reason why PCR followed by simple automated cleanup and mass spectrometry cannot be incorporated into a single integrated instrument. Essentially every configuration of the modern ESI mass spectrometer has been used successfully for the analysis of PCR products, from the highest to the lowest resolution involving. Fourier transform ion cyclotron resonance (FTICR), triple quadrupole, quadrupole-time of flight (Q-TOF), and ion trap.22-24 MS discriminates between two structurally related PCR products by MW difference. Mass accuracy is needed to differentiate the... [Pg.28]

Mass analyzers interrogate and resolve ions produced by an ion source based on their m/z ratios. Several types of mass analyzers are utilized for proteomic analysis including time-of-flight (TOF) quadrupoles, ion traps, and Fourier transform ion cyclotron resonance (FTICR). Mass analyzers may be assembled in hybrid configurations. MS instruments such as quadrupole TOF and quadra-pole ion trap-FTICR facilitate diversified applications and achieved great success. [Pg.381]

DGE a AC AMS APCI API AP-MALDI APPI ASAP BIRD c CAD CE CF CF-FAB Cl CID cw CZE Da DAPCI DART DC DE DESI DIOS DTIMS EC ECD El ELDI EM ESI ETD eV f FAB FAIMS FD FI FT FTICR two-dimensional gel electrophoresis atto, 10 18 alternating current accelerator mass spectrometry atmospheric pressure chemical ionization atmospheric pressure ionization atmospheric pressure matrix-assisted laser desorption/ionization atmospheric pressure photoionization atmospheric-pressure solids analysis probe blackbody infrared radiative dissociation centi, 10-2 collision-activated dissociation capillary electrophoresis continuous flow continuous flow fast atom bombardment chemical ionization collision-induced dissociation continuous wave capillary zone electrophoresis dalton desorption atmospheric pressure chemical ionization direct analysis in real time direct current delayed extraction desorption electrospray ionization desorption/ionization on silicon drift tube ion mobility spectrometry electrochromatography electron capture dissociation electron ionization electrospray-assisted laser desorption/ionization electron multiplier electrospray ionization electron transfer dissociation electron volt femto, 1CT15 fast atom bombardment field asymmetric waveform ion mobility spectrometry field desorption field ionization Fourier transform Fourier transform ion cyclotron resonance... [Pg.11]

Ion detection is carried out using image current detection with subsequent Fourier transform of the time-domain signal in the same way as for the Fourier transform ion cyclotron resonance (FTICR) analyzer (see Section 2.2.6). Because frequency can be measured very precisely, high m/z separation can be attained. Here, the axial frequency is measured, since it is independent to the first order on energy and spatial spread of the ions. Since the orbitrap, contrary to the other mass analyzers described, is a recent invention, not many variations of the instrument exist. Apart from Thermo Fischer Scientific s commercial instrument, there is the earlier setup described in References 245 to 247. [Pg.57]

Figure 2.19. Schematic of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (a) and a cylindrical cell (b). Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With... Figure 2.19. Schematic of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (a) and a cylindrical cell (b). Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With...
Fourier transform ion cyclotron resonance (FTICR) analyzer is excellent for MSn measurements (see Section 2.2.6), perhaps even more so, since the ions remain in the cell after detection. In principle one injection of ions is enough for a whole MSn sequence, including acquisition of a mass spectrum of each step. [Pg.96]

In addition to the diversity of ionisation techniques available, mass spectrometers offer a selection of mass analyser configurations. Of note are single (MS) and triple quadrupole (MS—MS) instruments, ion trap analysers (MS)n, time-of-flight (ToF) analysers, sector field analysers, and Fourier transform-ion cyclotron resonance (FTICR) instruments. [Pg.147]

Laser desorption (LD) Fourier transform ion cyclotron resonance MS (FTICR-MS) in the positive mode was applied for the analysis of... [Pg.263]

Octadecyl sulfate sodium salt (Ci8H37-0-S03 Na+) was examined by laser desorption (LD) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) in the negative mode resulting in [M - H] ions. Little fragmentation was observed under these conditions [28]. [Pg.342]


See other pages where FTICR Fourier transform ion cyclotron is mentioned: [Pg.269]    [Pg.1184]    [Pg.122]    [Pg.3773]    [Pg.770]    [Pg.269]    [Pg.1184]    [Pg.122]    [Pg.3773]    [Pg.770]    [Pg.189]    [Pg.542]    [Pg.395]    [Pg.16]    [Pg.383]    [Pg.38]    [Pg.38]    [Pg.244]    [Pg.665]   


SEARCH



Cyclotron

FTICR

Fourier transform ion cyclotron

Ion cyclotron

Ion transformations

© 2024 chempedia.info