Fill time chromatography

The crowning development in MW determination was the invention of gel permeation chromatography, the antecedents of which began in 1952 and which was finally perfected by Moore (1964). A column is filled with pieces of cross-linked macroporous resin and a polymer solution (gel) is made to flow through the column. The polymer solute permeates the column more slowly when the molecules are small, and the distribution of molecules after a time is linked not only to the average MW but also, for the first time with these techniques, to the vital parameter of MW distribution. [Pg.331]

In order to reduce the time-consuming open-column chromatographic processes, conventional methods of hydrocarbon-group-type separation have been replaced by MPLC and HPLC. Flash column chromatography is a technique less commonly applied than open-column version, but several applications have been described [2,24—27]. The common technique version is to use a silica-gel-filled column for example, 230 to 400 mesh 20 X 1 cm column size with a back pressure of 1.5 X 10 Pa of an ambient gas such as nitrogen. Solvents are similar to the ones apphed in the case of open-column chromatography fractionations. [Pg.372]

Hydrolytic Kinetic Resolution (HKR) of epichlorohydrin. The HKR reaction was performed by the standard procedure as reported by us earlier (17, 22). After the completion of the HKR reaction, all of the reaction products were removed by evacuation (epoxide was removed at room temperature ( 300 K) and diol was removed at a temperature of 323-329 K). The recovered catalyst was then recycled up to three times in the HKR reaction. For flow experiments, a mixture of racemic epichlorohydrin (600 mmol), water (0.7 eq., 7.56 ml) and chlorobenzene (7.2 ml) in isopropyl alcohol (600 mmol) as the co-solvent was pumped across a 12 cm long stainless steel fixed bed reactor containing SBA-15 Co-OAc salen catalyst (B) bed ( 297 mg) via syringe pump at a flow rate of 35 p,l/min. Approximately 10 cm of the reactor inlet was filled with glass beads and a 2 pm stainless steel frit was installed at the outlet of the reactor. Reaction products were analyzed by gas chromatography using ChiralDex GTA capillary column and an FID detector. [Pg.391]

The current status of chromatography is shown in Table 10.25. Since reducing separation time is a major issue, there is a pronounced trend toward shorter columns filled with small particles. The current trends for lower flow (micro- and nano-LC) columns, and great strides to achieve (ultra-) fast chromatographic... [Pg.732]

Rebif is produced via recombinant DNA technology in a CHO cell line. It displays an identical amino acid sequence to that of native human IFN-P-la and, like the native product, is glycosylated. After cell culture the interferon is purified using a series of chromatographic steps (affinity, ion-exchange, gel-filtration and reverse-phase liquid chromatography). It is formulated as a sterile solution in pre-filled syringes and contains mannitol, HSA, sodium acetate, acetic acid and sodium hydroxide as excipients. It is administered subcutaneously three times weekly. [Pg.230]

Recently flow coulometry, which uses a column electrode for rapid electrolysis, has become popular [21]. In this method, as shown in Fig. 5.34, the cell has a columnar working electrode that is filled with a carbon fiber or carbon powder and the solution of the supporting electrolyte flows through it. If an analyte is injected from the sample inlet, it enters the column and is quantitatively electrolyzed during its stay in the column. From the peak that appears in the current-time curve, the quantity of electricity is measured to determine the analyte. Because the electrolysis in the column electrode is complete in less than 1 s, this method is convenient for repeated measurements and is often used in coulometric detection in liquid chromatography and flow injection analyses. Besides its use in flow coulometry, the column electrode is very versatile. This versatility can be expanded even more by connecting two (or more) of the column electrodes in series or in parallel. The column electrodes are used in a variety of ways in non-aqueous solutions, as described in Chapter 9. [Pg.147]


See other pages where Fill time chromatography is mentioned: [Pg.153]    [Pg.15]    [Pg.29]    [Pg.425]    [Pg.1550]    [Pg.21]    [Pg.459]    [Pg.369]    [Pg.211]    [Pg.66]    [Pg.76]    [Pg.159]    [Pg.231]    [Pg.499]    [Pg.110]    [Pg.127]    [Pg.124]    [Pg.37]    [Pg.274]    [Pg.223]    [Pg.61]    [Pg.97]    [Pg.430]    [Pg.69]    [Pg.370]    [Pg.181]    [Pg.435]    [Pg.402]    [Pg.177]    [Pg.171]    [Pg.129]    [Pg.177]    [Pg.34]    [Pg.214]    [Pg.480]    [Pg.233]    [Pg.96]    [Pg.33]    [Pg.247]    [Pg.174]    [Pg.198]    [Pg.667]    [Pg.1061]    [Pg.19]    [Pg.396]   
See also in sourсe #XX -- [ Pg.501 , Pg.515 ]