Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Feeding circuit

The rated voltage of the system is 1500 V, and the capacity of the substation is assumed to be 4000 kW. The rated current of the substation f is [Pg.334]

If the backward impedance, that is, the voltage-fluctuation ratio ot the substation is 9% (= Z ), the internal voltage ot the substation model becomes [Pg.334]

The internal resistance is obtained from the backward impedance  [Pg.335]

If a voltage regulator is installed into a substation, the substation can be simply modeled with a small internal resistor , = 1 mil and an ideal source of 1690 V, which is fhe fargef volfage of fhe volfage regulator. [Pg.335]

The comparator in the figure determines fhe section where the train operates at the time. The comparator is represented by a nonlinear function (Device 56) and a truncation function TRUNC() installed in the TAGS. [Pg.335]


The former is to protect the human body from shock,s and electrocution, while the latter protects the circuit from fire risk. Normally the 300 mA GLCB is used as the incomer and 30 mA as the outgoing for the individual feeding circuits. [Pg.680]

NOTE LP coil boilers with integral recycle are designed with the drain from the water-steam separator recycled within the boiler feed circuits. LP coil boilers with external recycle are designed with the drain from the water-steam separator either being dumped or recycled to the FW tank. [Pg.593]

Effective control of the flow of slurry mixture to a large number of parallel flow paths. (Currently, flow control has been demonstrated on only three parallel paths, whereas the full-scale application would have up to 432 parallel flow paths in the catholyte feed circuit.)... [Pg.150]

Bouret SC, Simerly RB. Minireview Leptin and development of hypothalamic feeding circuits. Endocrinology 2004 145 2621-2626. [Pg.159]

On the industrial scale, heat exchangers (5) are therefore included in the feed circuit In laboratory units this temperature drop may be neglected, because the membrane area is commonly small in comparison to the recirculation rate of the feed, which is maintained at a controlled temperature. The permeate vapor is recovered in condensers at a temperature that allows a quantitative condensation of the vapor. The condensation can optionally be carried out in a series of condensation stages at different temperatures in order to achieve a permeate fractionation and increased enrichment of target compounds (3). [Pg.281]

Brief reference has already been made to the experimental measurement of crystal nucleation and growth rates in section 6.2.5, and a continuous MSMPR crystallizer suitable for the purpose is depicted in Figure 6.21. For cooling crystallization studies, only one feedstock storage vessel and delivery point would be needed. The duplicate feed circuits depicted in Figure 6.21 would be required if reaction crystallization, precipitation or salting-out studies are to be made. [Pg.430]

Figure 4.25 illustrates a numerical model of the single section of the feeding circuit. The substation is expressed by a series circuit of a diode D, an internal resistor R, and a voltage... [Pg.366]

Optimal installing position and capacity of the compensator. The numerical simulation using the EMTP enables a computer-aided design of feeding circuits of a dc train system. [Pg.332]


See other pages where Feeding circuit is mentioned: [Pg.278]    [Pg.32]    [Pg.151]    [Pg.262]    [Pg.118]    [Pg.149]    [Pg.134]    [Pg.620]    [Pg.157]    [Pg.12]    [Pg.364]    [Pg.366]    [Pg.366]    [Pg.366]    [Pg.367]    [Pg.333]    [Pg.333]    [Pg.334]    [Pg.334]   
See also in sourсe #XX -- [ Pg.333 , Pg.334 ]