Estimate resolution allowance

As shown along this chapter, a reliable air quality model is a valuable tool for human exposure studies, once modelled concentrations at different spatial scales and time resolutions allow to better characterising the air quality at the microenvironments visited by a target population, rather than monitoring values that are site and time specific. Moreover, air quality and exposure modelling approach considers the contribution of indoor environments, where people spend most of their time, to the exposure estimation. [Pg.271]

As mentioned in the introduction, a chiral auxiliary for asymmetric synthesis or kinetic resolution may not necessarily be enantiomerically pure. Even natural products considered to be composed of a single enantiomer may later be proven to be contaminated by minor amounts of the other enantiomer. Currently available techniques are estimated to allow the measurement of ees up to 99.99% (er = 20,000).16,17 These numbers define, for the time being, the experimental border between enantiopure and enantioimpure compounds. [Pg.259]

Resolution Allow ance Escalation Contingency Checking Criteria and Guidelines Offshore Cost Estimates... [Pg.106]

The degree of accuracy and the level of risk can be controlled through the judicious addition of resolution allowances to the various accounts and escalation and contingency to the estimate total. The application of these cost adjustment factors is discussed in Section 19.10. [Pg.120]

Finally, all estimates must include, as part of the individual accounts, a resolution allowance, plus escalation and contingency added to the bottom line. These cost items are discussed in the next section. [Pg.129]

When an estimate is based on firm vendors quotes and materials take-offs, experience shows that, invariably, some items affecting cost will be overlooked and left out of the estimate. To compensate for these oversights, it is appropriate to include in the estimate allowances for the unlisted items. These are called Resolution Allowances. [Pg.129]

As discussed in Section 10.4, the breakdown of cost items (take-offs) can go down to the level of nuts and bolts (detailed) or be based on larger, more comprehensive units (semi-detailed). Both approaches are valid provided that the scope of the unit prices corresponds to the units and that adequate resolution allowances are included to compensate for omissions and oversights. The estimate review must address the breakdown philosophy to ascertain that the unit prices and resolution allowance are consistent with the details of the take-offs. [Pg.132]

The expected increases in the equipment and commodity accounts should be considered a part of the base estimate rather than contingency. They should be included in the body of the estimate and identified as Resolution Allowances. The purpose of this guideline is to provide rational criteria to determine the appropriate resolution allowance on a consistent basis. [Pg.339]

The above contingencies are to be applied after the base estimate has been corrected with resolution allowances as previously indicated. [Pg.341]

Note For estimates based on take-offs from P ID s and Arrangement Drawings, a resolution allowance would be warranted at this stage. Resolution allowances would be from 5% to 30%, based on the design status. (See also Section 19.10 Adjustments. )... [Pg.437]

It is also possible to measure microwave spectra of some more strongly bound Van der Waals complexes in a gas cell ratlier tlian a molecular beam. Indeed, tire first microwave studies on molecular clusters were of this type, on carboxylic acid dimers [jd]. The resolution tliat can be achieved is not as high as in a molecular beam, but bulk gas studies have tire advantage tliat vibrational satellites, due to pure rotational transitions in complexes witli intennolecular bending and stretching modes excited, can often be identified. The frequencies of tire vibrational satellites contain infonnation on how the vibrationally averaged stmcture changes in tire excited states, while their intensities allow tire vibrational frequencies to be estimated. [Pg.2442]

PET has been gaining in popularity as a result of its enhanced sensitivity and resolution with respect to SPECT at the millimetre scale, allowing clinicians to study drug distribution in vivo (10). Indeed, it is estimated that by 2010 there will be approximately two million PET scans per year, of which the majority will image the metabolism of the 18F-labeled fluoro-deoxyglucose (FDG) (11). The increased sensitivity in turn reduces the concentration of the administered radiopharmaceutical required to 10 8-10 10M. The much lower concentrations of administered radioactive probe employed reduce the overall... [Pg.133]

In order to make a FPI chemical sensor, the FP cavity needs to be made accessible by the analyte molecules. One way to achieve this is to use a holey sleeve to host the cavity. Xiao et al.7 reported such a fiber FPI gas sensor formed by bonding two endface-polished fibers in a holey sleeve using epoxy. The holey sleeve allows gas to freely enter and leave the cavity. A resolution of 10 5 was estimated in monitoring the changes in the refractive index caused by varying the gas composition. However, the sensor assembly was complicated and required the use of epoxy. In addition, the various components used in sensor construction were made of different materials. As a result, the device had a strong dependence on temperature. [Pg.150]

As previously mentioned, resolution in CIEF strongly depends on the ampholyte composition. The estimated maximum resolving power of IEF is 0.02 pH units when carrier ampholytes are used to create the pH gradient.99 The Law of Monotony" formulated by Svensson in 1967 states that a natural pH gradient increases continually and monotonically from the anode to the cathode that the steady state does not allow for reversal of pH at any position along the gradient and that two ampholytes (in stationary electrolysis) cannot be completely separated from each other unless the system contains a third ampholyte of intermediate pH (or pi). The latter explains why better resolution is obtained when mixing ampholytes from different vendors and production batches as the number of ampholytes species increases, the chance that one or more ampholytes have intermediate pi relative to those of the sample components also increases. [Pg.199]


See other pages where Estimate resolution allowance is mentioned: [Pg.187]    [Pg.460]    [Pg.131]    [Pg.340]    [Pg.437]    [Pg.96]    [Pg.23]    [Pg.18]    [Pg.342]    [Pg.211]    [Pg.1486]    [Pg.104]    [Pg.259]    [Pg.254]    [Pg.33]    [Pg.29]    [Pg.159]    [Pg.375]    [Pg.726]    [Pg.148]    [Pg.418]    [Pg.238]    [Pg.68]    [Pg.57]    [Pg.418]    [Pg.458]    [Pg.4]    [Pg.56]    [Pg.219]    [Pg.396]    [Pg.150]    [Pg.176]    [Pg.179]    [Pg.212]    [Pg.183]   
See also in sourсe #XX -- [ Pg.129 , Pg.338 ]