Many of the variations developed to make pressure sensors and accelerometers for a wide variety of appHcations have been reviewed (5). These sensors can be made in very large batches using photoHthographic techniques that keep unit manufacturing costs low and ensure part-to-part uniformity. A pressure differential across these thin diaphragms causes mechanical deformation that can be monitored in several ways piezoresistors implanted on the diaphragm are one way changes in electrical capacitance are another. [Pg.390]

The primary reference method used for measuring carbon monoxide in the United States is based on nondispersive infrared (NDIR) photometry (1, 2). The principle involved is the preferential absorption of infrared radiation by carbon monoxide. Figure 14-1 is a schematic representation of an NDIR analyzer. The analyzer has a hot filament source of infrared radiation, a chopper, a sample cell, reference cell, and a detector. The reference cell is filled with a non-infrared-absorbing gas, and the sample cell is continuously flushed with ambient air containing an unknown amount of CO. The detector cell is divided into two compartments by a flexible membrane, with each compartment filled with CO. Movement of the membrane causes a change in electrical capacitance in a control circuit whose signal is processed and fed to a recorder. [Pg.196]

In many cases it is inconvenient to use a dipstick, due to the position or location of the tank, and there are a variety of direct and remote contents gauges available, including gauge glasses, float and weight, float and swing arm, float and indicator, hydrostatic, electrical capacitance, etc. [Pg.251]

Generally two main types of foam detector are used. They work by detecting either changes in electrical capacitance or changes in electrical resistance. Table 4.2 shows the application of foam detectors based on various principles, such as conductance, thermal conductivity, capacitance, ultrasonic rotating disks. [Pg.78]

A general method of estimating the temperature distribution in a body of any shape consists of replacing the heat flow problem by the analogous electrical situation and measuring the electrical potentials at various points. The heat capacity per unit volume C.,p is represented by an electrical capacitance, and the thermal conductivity k by an... [Pg.397]

Capacitance meters in which the electrical capacitance is a function of the degree of deposition of moisture from the atmosphere. [Pg.759]

Casadio, R., Venturoli, G. and Melandri, B. A. (1988). Evaluation of the electrical capacitance in biological membranes at different phospholipid to protein ratios -a study in photosynthetic bacterial chromatophores based on electrochromic effects, Eur. Biophys. J., 16, 243-253. [Pg.262]

Both types of Bourdon gauge are most suitable for use with corrosive gases and both can be used most effectively as null-point instruments. Several types of mechanical gauge are available commercially which use electrical capacitance or induction to magnify the mechanical movement of a membrane. Such gauges are easily operated in a differential mode and can be used for measuring pressure differences down to ca. 10 Torr. [Pg.50]

Electrode Charge Varies with Applied Potential Determination of the Electrical Capacitance of the Interlace... [Pg.142]

A solution of brain lipids was brushed across a small hole in a 5-ml. polyethylene pH cup immersed in an electrolyte solution. As observed under low power magnification, the thick lipid film initially formed exhibited intense interference colors. Finally, after thinning, black spots of poor reflectivity suddenly appeared in the film. The black spots grew rapidly and evenutally extended to the limit of the opening (5, 10). The black membranes have a thickness ranging from 60-90 A. under the electron microscope. Optical and electrical capacitance measurements have also demonstrated that the membrane, when in the final black state, corresponds closely to a bimolecular leaflet structure. Hence, these membranous structures are known as bimolecular, black, or bilayer lipid membranes (abbreviated as BLM). The transverse electrical and transport properties of BLM have been studied usually by forming such a structure interposed between two aqueous phases (10, 17). [Pg.112]

The electrical connection between detector and transistor was approximately 3 cm., the short lead distance is important in reducing stray electrical capacitance and microphonic noise owing to mechanical vibration. The circuit is a modified version of that of Bradley (3), with transistor types 2N4861 or 2N3823. [Pg.226]


See other pages where Capacitance electrical is mentioned: [Pg.563]    [Pg.460]    [Pg.308]    [Pg.331]    [Pg.763]    [Pg.765]    [Pg.544]    [Pg.593]    [Pg.508]    [Pg.314]    [Pg.357]    [Pg.544]    [Pg.579]    [Pg.108]    [Pg.182]    [Pg.364]    [Pg.87]    [Pg.95]    [Pg.284]    [Pg.338]    [Pg.622]    [Pg.168]    [Pg.258]    [Pg.10]    [Pg.348]    [Pg.697]    [Pg.195]    [Pg.172]    [Pg.177]    [Pg.9]    [Pg.574]    [Pg.35]    [Pg.460]    [Pg.259]    [Pg.466]    [Pg.10]    [Pg.369]   
See also in sourсe #XX -- [ Pg.223 ]




SEARCH



Capacitance Testing, electrical properties

Capacitance electric double-layer

Capacitance equivalent electrical circuit with

Capacitance membrane, electrical

Capacitance, electric

Capacitively powered plasma, electrical

Current step, electrical double layer capacitance

Electrical capacitance techniques

Electrical capacitance tomography

Electrical capacitance tomography applications

Electrical capacitance volume

Electrical capacitance volume tomography

Electrical capacitance, protein

Electrical conductivity double-layer capacitance

Electrical double-layer capacitors capacitance properties

Electrical double-layer capacitors capacitance values

Film Thickness by Electrical Capacitance

© 2024 chempedia.info