Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sampling, down

Only in a few cases are test samples measurable without any treatment. As a rule, test samples have to be transformed into a measurable form that optimally corresponds to the demands of the measuring technique. Therefore, sample preparation is a procedure that converts a test sample into a measuring sample. Whereas test samples represent the material in its original form, measuring samples embodies a form that is able to interact with the measuring system in an optimum way. In this sense, measuring samples can be solutions, extracts, pellets, and melt-down samples, but also definite surface layers and volumes in case of micro- and nanoprobe techniques. [Pg.50]

There are various physical and chemical methods of arresting or slowing down sample degradation (see Table 3.5). It is vital to verify that the integrity of the analyte is not affected by the method used to prevent degradation. This should be checked during method validation. [Pg.46]

To summarize, the classical method for analyzing sample rate conversion is to assume that the sample rate conversion factor is or can be approximated by a rational number. Then the sample rate conversion can be viewed as a three stage process, up-sample by an integer factor L, filter by h[n, and down-sample by M. Up-sampling by L inserts L — 1 zero valued samples in between the existing samples of x and decimating by M retains only each M-th sample. This approach is an analytical tool rather than an actual implementation strategy, and it allows the comparison of different sample rate conversion methods in a similar framework. [Pg.178]

Suppression rules. Let X(p,Qk) denote the short-time Fourier transform of x[ri, where p is the time index, and Qk the normalized frequency index (0t lies between 0 and 1 and takes N discrete values for k = 1,N, Wbeing the number of sub-bands). Note that the time index p usually refers to a sampling rate lower than the initial signal sampling rate (for the STFT, the down-sampling factor is equal to hop-size between to consecutive short-time frames) [Crochiere and Rabiner, 1983]. [Pg.384]

Figure 8.6 Classical sample rate conversion chain up-sampling by L, filtering, and down-sampling by M... Figure 8.6 Classical sample rate conversion chain up-sampling by L, filtering, and down-sampling by M...
EN 12131 (1998) Determination of the quantitative composition of feather and down, describes how the composition of down samples is to be analyzed, calculated and reported. [Pg.43]

Feather and down-sampling in view of tests Part 2 EN 1883... [Pg.44]

EN 1883 1998E, Feather and down-Sampling in view of tests Table A.l andTable A.2. CEN Brussels, 1998. [Pg.45]

Due to the down-sampling procedure during decomposition, the number of resulting wavelet coefficients (i.e., approximations and details) at each level is exactly the same as the number of input points for this level. It is sufficient to keep all detail coefficients and the final approximation coefficient (at the coarsest level) to be able to reconstruct the original data. The... [Pg.125]

An important property of wavelet bases is their lack of translational invariance. In other words, when a pattern is translated, its descriptors are not only translated but also modified. This is a direct consequence of the down-sampling procedure and leads to distorted reconstruction of the underlying signal features. A possible solution is to omit down-sampling, resulting in a redundant family of coefficients. [Pg.127]

FIGURE 4.9 Schematic image of wavelet decomposition. The QMFs H and G are applied iteratively to each coarse coefficient set. The raw signal CW down sampled, leading to sets of coarse (C) and detail (D) coefficients of half the size. [Pg.102]

The strengths of the platform are the very small liquid volumes in the nanoliter range that can be handled with high precision, and the freedom to program the droplet movement. This cuts down sample and reagent consumption and allows a maximum of flexibility for the implementation of different assay... [Pg.347]

Since m determines the number of bands in the DWT and the down-sampling factor, we choose m such that p/m j + is an integer value. [Pg.190]

Practice, practice, practice. Rehearse what you d like to say before dialing a number or going to a meeting. Write down sample openings or questions and practice saying them. [Pg.13]

To demonstrate the performance of the proposed hybrid technique, the input video sequences are down-sampled in the spatial domain by deleting alternate rows and columns at (4 1) and (16 1) compression ratio respectively. Then for each scheme, we interpolate the frames back to their original size to allow the comparison with the original video frame. Tables 2 and 3 illustrate theaverage PSNR comparison of DCT,... [Pg.65]

As in chiral purification, the mobile phase is dramatically cheaper than in HPLC. Less toxic waste is generated, and much less power is required to dry down samples. One of the biggest advantages of SFC is actually in the postpurification sample handling. The fractions tend to be much smaller and are 100% organic, allowing much faster, much easier, much cheaper dry-down. [Pg.4584]

Flgme 2. (a) Crystallization curves of high-density polyethylene and ethylene-vinyl acetate random copolymers with various vinyl acetate content, cooling rate = 10 °C/ min The vinyl acetate content is indicated at each curve. Exotherm is up. (b) melting curves of the same samples recorded at 10°C/min heating rates. Endotherm is down. Samples from Scientific Polymer Products, Inc. (Menczel, unpublished results.)... [Pg.113]

The other use is to quickly brighten up a track (enhance), especially one that has been softened with any number of other effects. One example might be a track that has been compressed to make it a bit louder in a mix. This can sometimes result in a flatter, less lively sound. Another notable example is when down sampling. Down sampling is the process of changing the sample rate from, say, an audio CD at 44,100 Hz to 11,025 Hz for distribution over the Internet. The Smooth Enhance plug-in has one simple Operation slider that is used to control the effect. [Pg.174]


See other pages where Sampling, down is mentioned: [Pg.450]    [Pg.167]    [Pg.284]    [Pg.286]    [Pg.77]    [Pg.251]    [Pg.33]    [Pg.124]    [Pg.15]    [Pg.54]    [Pg.383]    [Pg.92]    [Pg.102]    [Pg.138]    [Pg.178]    [Pg.181]    [Pg.466]    [Pg.55]    [Pg.77]    [Pg.86]    [Pg.813]    [Pg.1885]    [Pg.310]    [Pg.257]    [Pg.63]    [Pg.122]    [Pg.122]    [Pg.16]    [Pg.56]   
See also in sourсe #XX -- [ Pg.174 ]




SEARCH



Samples, contamination cutting down

© 2024 chempedia.info