Dispersion of/’peak

In the heavily OD regime, where Asc and /.jes become smaller than mp, the dispersion of ,peak(k) becomes wider than Asc and Wpeak [see Eqs. (20), (24) and (25)]. This results in the smearing of the peak in spectroscopies where it is integrated over the BZ, though it may still be detected in different k points [where there remains some smearing, as was mentioned below Eq. (25)]. The... [Pg.208]

Here, the Hnear dependence of the diagonal components of terms such as -pBo(l + causes the increased dispersion of peaks at higher magnetic fields. [Pg.183]

Calculations of model spectra (distribution functions/(6jj) of chemical shifts of protons) using Gaussian functions and parameters of dispersion of peaks from the experimental NMR spectra (or theoretical estimations) as described in Chapter 10. Such approach allows us to calculate appropriate NMR spectra of large systems. This information can be used for more reliable and detailed analysis of the experimental NMR spectra. [Pg.248]

The dispersion of peak A is smaller, but nevertheless definite, as shown in fig. 50 where the dispersion becomes more evident as the spectra near F are expanded. The data shown here were taken at a photon energy of 35eV and have been smoothed with a 30meV FWHM Gaussian (i.e., smaller width than instrument resolution). The peak normalization is arbitrary, chosen primarily to emphasize dispersion. In actual fact, peak A is nearly absent near F. Interestingly, band A disperses below as its intensity decreases, which is similar to the effect seen in Ce heavy fermions above. [Pg.356]

The AeroSizer, manufactured by Amherst Process Instmments Inc. (Hadley, Massachusetts), is equipped with a special device called the AeroDisperser for ensuring efficient dispersal of the powders to be inspected. The disperser and the measurement instmment are shown schematically in Figure 13. The aerosol particles to be characterized are sucked into the inspection zone which operates at a partial vacuum. As the air leaves the nozzle at near sonic velocities, the particles in the stream are accelerated across an inspection zone where they cross two laser beams. The time of flight between the two laser beams is used to deduce the size of the particles. The instmment is caUbrated with latex particles of known size. A stream of clean air confines the aerosol stream to the measurement zone. This technique is known as hydrodynamic focusing. A computer correlation estabUshes which peak in the second laser inspection matches the initiation of action from the first laser beam. The equipment can measure particles at a rate of 10,000/s. The output from the AeroSizer can either be displayed as a number count or a volume percentage count. [Pg.134]

Method of Moments The first step in the analysis of chromatographic systems is often a characterization of the column response to sm l pulse injections of a solute under trace conditions in the Henry s law limit. For such conditions, the statistical moments of the response peak are used to characterize the chromatographic behavior. Such an approach is generally preferable to other descriptions of peak properties which are specific to Gaussian behavior, since the statisfical moments are directly correlated to eqmlibrium and dispersion parameters. Useful references are Schneider and Smith [AJChP J., 14, 762 (1968)], Suzuki and Smith [Chem. Eng. ScL, 26, 221 (1971)], and Carbonell et al. [Chem. Eng. Sci., 9, 115 (1975) 16, 221 (1978)]. [Pg.1532]

The horizontal dispersion of a plume has been modeled by the use of expanding cells well mixed vertically, with the chemistry calculated for each cell (31). The resulting simulation of transformation of NO to NO2 in a power plant plume by infusion of atmospheric ozone is a peaked distribution of NO2 that resembles a plume of the primary pollutants, SO2 and NO. The ozone distribution shows depletion across the plume, with maximum depletion in the center at 20 min travel time from the source, but relatively uniform ozone concentrations back to initial levels at travel distances 1 h from the source. [Pg.330]

It has also been shown that the effect of sample volume on peak width will be most significant for the early peaks (the most narrow peaks). In addition, the degrading effect of sample volume will progressively decrease as the capacity ratio of the peak becomes larger. However, the resolution of both late and early peaks are equally important and, consequently, the limiting sample volume will be that which restrains the dispersion of the first peak to 5% or less. [Pg.208]

The dispersion of a solute band in a packed column was originally treated comprehensively by Van Deemter et al. [4] who postulated that there were four first-order effect, spreading processes that were responsible for peak dispersion. These the authors designated as multi-path dispersion, longitudinal diffusion, resistance to mass transfer in the mobile phase and resistance to mass transfer in the stationary phase. Van Deemter derived an expression for the variance contribution of each dispersion process to the overall variance per unit length of the column. Consequently, as the individual dispersion processes can be assumed to be random and non-interacting, the total variance per unit length of the column was obtained from a sum of the individual variance contributions. [Pg.245]

Thus, a practical procedure would be as follows. Initially the HETP of a series of peptides of known molecular weight must be measured at a high mobile phase velocity to ensure a strong dependence of peak dispersion on solute diffusivity. [Pg.355]

Nitrogen adsorption experiments showed a typical t)q5e I isotherm for activated carbon catalysts. For iron impregnated catalysts the specific surface area decreased fix>m 1088 m /g (0.5 wt% Fe ) to 1020 m /g (5.0 wt% Fe). No agglomerization of metal tin or tin oxide was observed from the SEM image of 5Fe-0.5Sn/AC catalyst (Fig. 1). In Fig. 2 iron oxides on the catalyst surface can be seen from the X-Ray diffractions. The peaks of tin or tin oxide cannot be investigated because the quantity of loaded tin is very small and the dispersion of tin particle is high on the support surface. [Pg.278]

There are generally three types of peaks pure 2D absorption peaks, pure negative 2D dispersion peaks, and phase-twisted absorption-dispersion peaks. Since the prime purpose of apodization is to enhance resolution and optimize sensitivity, it is necessary to know the peak shape on which apodization is planned. For example, absorption-mode lines, which display protruding ridges from top to bottom, can be dealt with by applying Lorentz-Gauss window functions, while phase-twisted absorption-dispersion peaks will need some special apodization operations, such as muliplication by sine-bell or phase-shifted sine-bell functions. [Pg.180]

All MC-ICPMS instruments are equipped with a multiple Faraday collector array oriented perpendicular to the optic axis, enabling the simultaneous static or multi-static measurement of up to twelve ion beams. Most instruments use Faraday cups mounted on motorized detector carriers that can be adjusted independently to alter the mass dispersion and obtain coincident ion beams, as is the approach adopted for MC-TIMS measurement. However, some instruments instead employ a fixed collector array and zoom optics to achieve the required mass dispersion and peak coincidences (e.g., Belshaw et al. 1998). [Pg.43]

Figure 8. Schematic outline of a second-generation MC-ICPMS instrument (Nu Instalments Nu Plasma), equipped with a multiple-Faraday collector block for the simultaneous measurement of up to 12 ion beams, and three electron multipliers (one operating at high-abundance sensitivity) for simultaneous low-intensity isotope measurement. This instmment uses zoom optics to obtain the required mass dispersion and peak coincidences in place of motorized detector carriers. [Used with permission of Nu Instruments Ltd.]... Figure 8. Schematic outline of a second-generation MC-ICPMS instrument (Nu Instalments Nu Plasma), equipped with a multiple-Faraday collector block for the simultaneous measurement of up to 12 ion beams, and three electron multipliers (one operating at high-abundance sensitivity) for simultaneous low-intensity isotope measurement. This instmment uses zoom optics to obtain the required mass dispersion and peak coincidences in place of motorized detector carriers. [Used with permission of Nu Instruments Ltd.]...

See other pages where Dispersion of/’peak is mentioned: [Pg.347]    [Pg.356]    [Pg.347]    [Pg.356]    [Pg.2205]    [Pg.651]    [Pg.255]    [Pg.11]    [Pg.75]    [Pg.20]    [Pg.191]    [Pg.232]    [Pg.237]    [Pg.237]    [Pg.258]    [Pg.267]    [Pg.428]    [Pg.131]    [Pg.132]    [Pg.52]    [Pg.246]    [Pg.1290]    [Pg.392]    [Pg.111]    [Pg.253]    [Pg.276]    [Pg.321]    [Pg.610]    [Pg.366]    [Pg.99]    [Pg.505]    [Pg.508]    [Pg.739]    [Pg.801]    [Pg.339]   
See also in sourсe #XX -- [ Pg.349 ]




SEARCH



Dynamics of peak dispersion

Peak dispersion (

The Dynamics of Peak Dispersion