Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Discrete certified

Their selection should be carefully conducted, since they function as pure weighting factors and therefore they can strongly subdue dispersion and dissipation errors. Also, correction functions df co, At) and LA() of (3.71) and (3.74) are selected to lessen grid discrepancies and certify the proper transition from the continuous physical space to the discretized domain. In fact, their arguments have a substantial contribution in the method s wideband profile and hence involve an in-depth examination. More specifically, by considering the excitation frequency content and duration, they subdue oscillatory or spurious modes that corrupt the final waveform envelope. Probing kf, LA() analysis indicates that its argument should opt... [Pg.78]

Time Series A time series is a sequence of observations that are ordered in time (or possibly space). A relevant example would be the analytical data obtained for a quality control (QC) sample or a certified reference material (CRM) on a weekly basis. If such measurements are made as a function of time, it is sensible to display the data in the order in which they were obtained, best in a scatter plot in which the measured value x is plotted as a function of time as the independent variable (in this case, however, something over which we have little control ). There are two kinds of time series data, continuous in which data are recorded at every instant of time (e.g., temperature and/or humidity in a climate-controlled laboratory), and discrete in which data are recorded at (usually regularly) spaced intervals, e.g, the QC analyses mentioned above. [Pg.457]

To help resolve potential ambiguities these measurements and data may be certified as accurate by the representative of the inspected State Party, at the discretion of the inspected State Party, immediately after they are gathered. In case of discrepancies both Parties shall make efforts to resolve discrepancies as soon as possible before the end of the inspection period. If necessary, the representative of the inspected State Party and the inspector shall each record the method(s) used and the final result(s). Such measurements shall be recorded in the document on preliminary findings. [Pg.340]

Some commenters asserted that the containment procedures were not stringent enough. Some suggested that EPA follow the HUD Guidelines with respect to exterior containment requirements. Others asked EPA to strengthen exterior containment requirements by specifying that containment extend at least 20 feet to collect all debris and residue and that the rule address circumstances such as wind and rain. One commenter asserted that allowing the certified renovator complete discretion to determine what is appropriate renders the worksite containment... [Pg.174]

In addition, in this rule EPA has established minimum containment requirements for both interior and exterior renovation requirements. While the certified renovator has discretion regarding the specific components and extent of containment, the renovator and firm will be in violation of this final rule if dust or debris leaves the work area for both interior and exterior renovations. If dust or debris migrates beyond the work area, that migration constitutes a violation of the rule. Accordingly, EPA does not agree with the commenter that the rule is unenforceable. [Pg.175]

A most useful approach has been published by Hirleman et al. This consisted of an artificial "aerosol" made up of an array of chrome thin-film circles on a transparent glass substrate. This calibration reticle contains more than 10000 of these particles randomly positioned in an 8 mm circle to simulate a Rosin Rammler distribution of spherical particles. Versions are available with different Rosin Rammler parameters X and N, and at least two levels of obscuration. The continuous Rosin Rammler size distribution is approximated on the reticle by 24 discrete particle sizes ranging from 2 to 105 m depending on the individual reticle. Each reticle is individually certified. An example of the goodness of fit to the Rosin Rammler distribution is shown in Figure 7. Hirleman et al use the reticle to check the performance of a Malvern 2200 model. [Pg.117]


See other pages where Discrete certified is mentioned: [Pg.588]    [Pg.82]    [Pg.134]    [Pg.67]    [Pg.352]    [Pg.362]    [Pg.493]    [Pg.191]    [Pg.352]    [Pg.594]    [Pg.449]    [Pg.239]    [Pg.188]    [Pg.289]    [Pg.18]    [Pg.278]    [Pg.1321]    [Pg.548]    [Pg.175]    [Pg.102]   
See also in sourсe #XX -- [ Pg.239 ]




SEARCH



Certifiable

© 2024 chempedia.info